Role of left bundle branch pacing in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block

Abstract Introduction Left bundle branch pacing was a novel advanced pacing method with a narrower-paced QRS duration. However, its role in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block was not sufficiently evaluated. Purpose To evaluate mechanical desynchrony and myocardial work characteristics after one year of pacing by left bundle branch pacing versus right ventricular pacing in patients with atrial ventricular block. Methods A prospective, observation study in 80 patients with second-degree type 2 and third-degree atrial ventricular block (40 patients with LBBP and 40 with right septal ventricular pacing RVP). All patients performed echocardiography before implantation and after one year. Results The characteristics before implantation (age, gender, ejection fraction, QRS duration) and percentage of pacing were not significantly different between the two groups, but after implantation, paced QRS duration in LBBP pacing was significantly narrower than that in the RVP group (LBBP: 112±18ms, RVP: 139ms ±12ms, p<0.05). After 12 months, in electromechanical synchrony, LBBP induced significantly shorter peak strain dispersion (45.6 ±17.1ms vs. 54.26±12.7ms, P<0.05) and interventricular mechanical delay ([8.0ms (4.3–16.8) vs. 15.0ms(2.5–26.0), P<0.05) than RVP group. Compared with RVP group, LBBP induced greater global longitudinal strain (13.8±2.6% vs. 17.1±2.4%, P<0.05), global myocardial work index (1416.3±268.9mmHg% vs. 1974.3±624.1mmHg%, P<0.05) and global constructive work (1925.5±521.0 mmHg% vs. 2232.5 ±461.5 mmHg%, P<0.05). Conclusion After 12 months post-pacing, LBBP demonstrated better electromechanical synchrony, global longitudinal strain, and myocardial work than RVP.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.555
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of left bundle branch pacing in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block

K.V. VO, S Truong, Lynn Huong, Hùng Nguyễn Văn et al.
3 links
EP Europace
Cardiac pacing and defibrillation studies
article

Role of left bundle branch pacing in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block

K.V. VO, S Truong, Lynn Huong, Hùng Nguyễn Văn, L Y Nguyen Thi Kieu
article en

Abstract

Abstract Introduction Left bundle branch pacing was a novel advanced pacing method with a narrower-paced QRS duration. However, its role in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block was not sufficiently evaluated. Purpose To evaluate mechanical desynchrony and myocardial work characteristics after one year of pacing by left bundle branch pacing versus right ventricular pacing in patients with atrial ventricular block. Methods A prospective, observation study in 80 patients with second-degree type 2 and third-degree atrial ventricular block (40 patients with LBBP and 40 with right septal ventricular pacing RVP). All patients performed echocardiography before implantation and after one year. Results The characteristics before implantation (age, gender, ejection fraction, QRS duration) and percentage of pacing were not significantly different between the two groups, but after implantation, paced QRS duration in LBBP pacing was significantly narrower than that in the RVP group (LBBP: 112±18ms, RVP: 139ms ±12ms, p<0.05). After 12 months, in electromechanical synchrony, LBBP induced significantly shorter peak strain dispersion (45.6 ±17.1ms vs. 54.26±12.7ms, P<0.05) and interventricular mechanical delay ([8.0ms (4.3–16.8) vs. 15.0ms(2.5–26.0), P<0.05) than RVP group. Compared with RVP group, LBBP induced greater global longitudinal strain (13.8±2.6% vs. 17.1±2.4%, P<0.05), global myocardial work index (1416.3±268.9mmHg% vs. 1974.3±624.1mmHg%, P<0.05) and global constructive work (1925.5±521.0 mmHg% vs. 2232.5 ±461.5 mmHg%, P<0.05). Conclusion After 12 months post-pacing, LBBP demonstrated better electromechanical synchrony, global longitudinal strain, and myocardial work than RVP.

EP EuropaceVol. 27(Supplement_1)
108 Military Central Hospital (VN)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Role of left bundle branch pacing in preserving mechanical synchrony and myocardial work in patients with atrial ventricular block — K.V. VO, S Truong, et al. · EP Europace (2025) | TGRS Research Map | TGRS