Impact of additional pulsed field ablation in unsuccessful radiofrequency linear lesions -including the assessment of the LA wall thickness at the gap locations-

Abstract Background Performing linear ablation such as roof line, floor line in the posterior part of the LA, and posterior mitral isthmus (MI) line in addition to PVI is one of the strategies for treating persistent atrial fibrillation. However, remnant conduction or reconnection in the lines is linked with atrial arrhythmia recurrence, either AF or AT. Radiofrequency ablation (RFA) is often unsuccessful achieving durable linear ablation. It is not yet well known whether using pulsed field ablation (PFA) would be superior in achieving complete linear lesions in human. Purpose We sought to evaluate the wall thickness of the LA along the position of linear lesion and gaps in cases where linear lesion creation using RFA failed, and to evaluate the effectiveness of PFA on them. Methods We studied 21 patients that underwent redo procedures due to atrial arrhythmia recurrence. All of them underwent PFA (using a pentaspline PFA catheter) ablation lines due to previous unsuccessful RF ablation, either due to remnant conduction in the line or to reconnection of the line. Lines of block were evaluated based on activation mapping and differential pacing maneuvers close to the lines. Furthermore, regarding dome-transection lines, the linear lesions created by RFA, and the positions of their gaps were projected onto the 3D reconstructed image from CT taken before procedure, and the wall thickness at positions along them was evaluated postoperatively. Results We conducted 20 dome-posterior lines and 6 posterolateral mitral isthmus lines using PFA after several times unsuccessful linear lesions by RFA. Dome-posterior line bidirectional block based on activation mapping and differential pacing maneuvers was achieved in all cases (20/20, 100%) after PFA. Posterior MI line bidirectional block based on activation mapping and differential pacing maneuvers was achieved in 5 out of 6 patients (83.3%). In one case additional Et-VOM was needed to achieve MI block. 6 patients have experienced AT/AF recurrence after PFA. Three of them underwent redo procedure, but no reconnection of these linear lesions treated with PFA was observed. Regarding the assessment of LA wall thickness, the mean LA wall thickness at positions along the gap location was thicker compared to the mean LA wall thickness at positions along the linear lesion created by RFA (2.49±0.43mm vs 1.91±0.41mm; 95%CI 0.48-0.68; p<0.001). Conclusion PFA treatment seems promising to back-up RF failed linear lesions. Furthermore, when creating a linear lesion using RFA, it may be better to ablate while avoiding locations with thick walls based on a prior evaluation of wall thickness. If the wall thickness at the target location is thick overall, it may be better to create a linear lesion using PFA instead of RFA. However, we cannot exclude that it is in fact the combination of the 2 energies that was successful in those resistant cases.Figure

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.482
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of additional pulsed field ablation in unsuccessful radiofrequency linear lesions -including the assessment of the LA wall thickness at the gap locations-

Josselin Duchâteau, Karim Bénali, Cinzia Monaco, Hubert Cochet et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Impact of additional pulsed field ablation in unsuccessful radiofrequency linear lesions -including the assessment of the LA wall thickness at the gap locations-

Josselin Duchâteau, Karim Bénali, Cinzia Monaco, Hubert Cochet, Marine Arnaud, Frédéric Sacher, Romain Tixier, Konstantinos Vlachos, Pierre Jaı̈s, Thomas Pambrun, Benjamin Bouyer, Mélèze Hocini, Kinan Kneizeh, N. Derval, Masaaki Yokoyama
article en

Abstract

Abstract Background Performing linear ablation such as roof line, floor line in the posterior part of the LA, and posterior mitral isthmus (MI) line in addition to PVI is one of the strategies for treating persistent atrial fibrillation. However, remnant conduction or reconnection in the lines is linked with atrial arrhythmia recurrence, either AF or AT. Radiofrequency ablation (RFA) is often unsuccessful achieving durable linear ablation. It is not yet well known whether using pulsed field ablation (PFA) would be superior in achieving complete linear lesions in human. Purpose We sought to evaluate the wall thickness of the LA along the position of linear lesion and gaps in cases where linear lesion creation using RFA failed, and to evaluate the effectiveness of PFA on them. Methods We studied 21 patients that underwent redo procedures due to atrial arrhythmia recurrence. All of them underwent PFA (using a pentaspline PFA catheter) ablation lines due to previous unsuccessful RF ablation, either due to remnant conduction in the line or to reconnection of the line. Lines of block were evaluated based on activation mapping and differential pacing maneuvers close to the lines. Furthermore, regarding dome-transection lines, the linear lesions created by RFA, and the positions of their gaps were projected onto the 3D reconstructed image from CT taken before procedure, and the wall thickness at positions along them was evaluated postoperatively. Results We conducted 20 dome-posterior lines and 6 posterolateral mitral isthmus lines using PFA after several times unsuccessful linear lesions by RFA. Dome-posterior line bidirectional block based on activation mapping and differential pacing maneuvers was achieved in all cases (20/20, 100%) after PFA. Posterior MI line bidirectional block based on activation mapping and differential pacing maneuvers was achieved in 5 out of 6 patients (83.3%). In one case additional Et-VOM was needed to achieve MI block. 6 patients have experienced AT/AF recurrence after PFA. Three of them underwent redo procedure, but no reconnection of these linear lesions treated with PFA was observed. Regarding the assessment of LA wall thickness, the mean LA wall thickness at positions along the gap location was thicker compared to the mean LA wall thickness at positions along the linear lesion created by RFA (2.49±0.43mm vs 1.91±0.41mm; 95%CI 0.48-0.68; p<0.001). Conclusion PFA treatment seems promising to back-up RF failed linear lesions. Furthermore, when creating a linear lesion using RFA, it may be better to ablate while avoiding locations with thick walls based on a prior evaluation of wall thickness. If the wall thickness at the target location is thick overall, it may be better to create a linear lesion using PFA instead of RFA. However, we cannot exclude that it is in fact the combination of the 2 energies that was successful in those resistant cases.Figure

EP EuropaceVol. 27(Supplement_1)
Hôpital Cardiologique du Haut-Lévêque (FR)
Agence Nationale de la Recherche
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.