Loss of RBB delay pattern in lead V1 at follow-up and persistent left bundle branch area pacing: can it be possible?

Abstract Background The appearance of a right bundle branch (RBB) delay pattern in lead V1 (qR/QR/rSr`) is a necessary criterion to confirm successful LBBAP; however, whether this pattern persists during follow-up is unknown Purpose To determine persistence of RBB delay pattern in confirmed LBBA captures at follow-up and factors related to its disappearance. Methods Consecutive patients with successful LBBAP for bradycardia pacing indication and preserved LVEF were selected. At follow-up, a 12-lead ECG was recorded after programming in VVI mode with lower rate at least 10 bpm over patient´s intrinsic rhythm and unipolar pacing configuration. Results 149 patients were analyzed (mean age 77.3±9.9years, 52.3% male). Non-diseased LBB was present in 73.2% of patients. Average baseline QRS complex duration was of 116.6±28.2 and it was 115.7±12.9 ms after LBBAP. LBBP was demonstrated in 114 patients (76.5%) and LVSP in 35 patients (23.5%). A qR/QR/rSr` pattern in lead V1 of the paced QRS complex was present in 142 out of 149 patients with successful LBBAP at implant. After 18.2 ± 7.3 months of follow-up visit, in 113 patients (79.6%) the RBB delay pattern in lead V1 during unipolar pacing remained, it disappeared in 29 patients (20.4%) and was not demonstrated in none of the 7 patients who did not show it at implant. In patients who lost the RBB delay pattern at follow-up, paced QRS morphology remained narrow and without W or LBB morphology (figure 1). Duration of the paced QRS complex persisted unchanged: p-QRS-stim at implant was 111.3±10.7 vs 109.6±12.5 at follow-up (p=0.413) and p-QRS-onset at implant was 141.4±10.4 vs 138.9±14.3 at follow-up (p=0.266). Moreover, V6-RWPT at implant was similar to V6-RWPT at follow-up, among patients with confirmed LBB capture (73.4±5.9 vs 73.1±6.9 ms, respectively; p=0.860) and among LVSP captures (86.3±5.6 vs 85.3±8.1 ms, respectively; p=0.658). Baseline characteristic were similar among patient with and without RBB delay pattern in lead V1 at follow-up. However, loss of RBB delay pattern at follow-up tended to be less frequent in cases with proven left conduction potential, it did not appear in any case of left bundle trunk pacing and was significantly more frequent among left fascicular captures, especially when pacing the left anterior fascicle (p=0.002) (table 1). In patients with confirmed LBB capture, paced QRS complex at implant was shorter among those who lost the RBB delay pattern at follow-up compared to captures that kept this pattern (table 1). A multivariate logistic regression analysis revealed that shorter p-QRS-stim at implant (OR 0.925, 95% confidence interval (CI): 0.876-0.976; p=0.005) and left anterior fascicular pacing (OR 13.085, 95% CI: 1.750-97.808; p=0.012) were predictors of loss of RBB delay pattern at follow-up. Conclusions In 1 out of 5 patients receiving LBBAP the qR/QR/rSr` pattern in lead V1 disappeared at follow-up and therefore delay in RV activation might be buffered over time.Figure 1 Table 1

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.533
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Loss of RBB delay pattern in lead V1 at follow-up and persistent left bundle branch area pacing: can it be possible?

A Estevez Paniagua, Silvia Jiménez Loeches, S Briongos Figuero, D Heredero et al.
EP Europace
Cardiac pacing and defibrillation studies
article

Loss of RBB delay pattern in lead V1 at follow-up and persistent left bundle branch area pacing: can it be possible?

A Estevez Paniagua, Silvia Jiménez Loeches, S Briongos Figuero, D Heredero, E Sanchez Lopez, M Tapia Martinez, R Munoz Aguilera, A Luna Cabadas, A Sanchez Hernandez
article en

Abstract

Abstract Background The appearance of a right bundle branch (RBB) delay pattern in lead V1 (qR/QR/rSr`) is a necessary criterion to confirm successful LBBAP; however, whether this pattern persists during follow-up is unknown Purpose To determine persistence of RBB delay pattern in confirmed LBBA captures at follow-up and factors related to its disappearance. Methods Consecutive patients with successful LBBAP for bradycardia pacing indication and preserved LVEF were selected. At follow-up, a 12-lead ECG was recorded after programming in VVI mode with lower rate at least 10 bpm over patient´s intrinsic rhythm and unipolar pacing configuration. Results 149 patients were analyzed (mean age 77.3±9.9years, 52.3% male). Non-diseased LBB was present in 73.2% of patients. Average baseline QRS complex duration was of 116.6±28.2 and it was 115.7±12.9 ms after LBBAP. LBBP was demonstrated in 114 patients (76.5%) and LVSP in 35 patients (23.5%). A qR/QR/rSr` pattern in lead V1 of the paced QRS complex was present in 142 out of 149 patients with successful LBBAP at implant. After 18.2 ± 7.3 months of follow-up visit, in 113 patients (79.6%) the RBB delay pattern in lead V1 during unipolar pacing remained, it disappeared in 29 patients (20.4%) and was not demonstrated in none of the 7 patients who did not show it at implant. In patients who lost the RBB delay pattern at follow-up, paced QRS morphology remained narrow and without W or LBB morphology (figure 1). Duration of the paced QRS complex persisted unchanged: p-QRS-stim at implant was 111.3±10.7 vs 109.6±12.5 at follow-up (p=0.413) and p-QRS-onset at implant was 141.4±10.4 vs 138.9±14.3 at follow-up (p=0.266). Moreover, V6-RWPT at implant was similar to V6-RWPT at follow-up, among patients with confirmed LBB capture (73.4±5.9 vs 73.1±6.9 ms, respectively; p=0.860) and among LVSP captures (86.3±5.6 vs 85.3±8.1 ms, respectively; p=0.658). Baseline characteristic were similar among patient with and without RBB delay pattern in lead V1 at follow-up. However, loss of RBB delay pattern at follow-up tended to be less frequent in cases with proven left conduction potential, it did not appear in any case of left bundle trunk pacing and was significantly more frequent among left fascicular captures, especially when pacing the left anterior fascicle (p=0.002) (table 1). In patients with confirmed LBB capture, paced QRS complex at implant was shorter among those who lost the RBB delay pattern at follow-up compared to captures that kept this pattern (table 1). A multivariate logistic regression analysis revealed that shorter p-QRS-stim at implant (OR 0.925, 95% confidence interval (CI): 0.876-0.976; p=0.005) and left anterior fascicular pacing (OR 13.085, 95% CI: 1.750-97.808; p=0.012) were predictors of loss of RBB delay pattern at follow-up. Conclusions In 1 out of 5 patients receiving LBBAP the qR/QR/rSr` pattern in lead V1 disappeared at follow-up and therefore delay in RV activation might be buffered over time.Figure 1 Table 1

EP EuropaceVol. 27(Supplement_1)
Hospital Central de la Defensa Gómez Ulla (ES), Hospital Universitario Infanta Leonor (ES)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.