Real-world experience of atrial fibrillation ablation using a variable-loop circular catheter: a single-centre study

Abstract Background The Variable-Loop Circular Catheter (VLCC) is a bidirectional multi-electrode catheter capable of electroanatomical mapping and pulsed field energy (PF) delivery for the treatment of atrial fibrillation (AF). Objective to report first experience with VLCC for AF ablation in a high-volume centre experienced with single-shot PF devices. Methods Consecutive AF patients undergoing AF ablation with VLCC were prospectively enrolled in our centre between April 2024 and October 2024. Pulmonary vein isolation (PVI) was performed using at least 16 applications per vein. The primary efficacy endpoint included acute electrical isolation of pulmonary veins (PVs) or posterior wall (PW) and bidirectional block in case of linear lesions. The primary safety endpoint was composite of periprocedural device-related major adverse events. Results We enrolled 32 (63.6 ± 10.2 years, 50% males, 28.1% Persistent AF) patients and a total of 130 PVs. All patients underwent PVI, 31.3% underwent PW isolation and 9.4% underwent additional lesions with VLCC (1 Cavotricuspid isthmus, 1 roof line and 1 anterior mitral line ablation). In 34.4% of the patients, deflectable sheath was used, while in the remaining 65.6% patients a fixed sheath was employed. Median procedural time was 60 min (50-90), dwelling time 30 min (25-50) and fluoroscopy time 5 min (3-10). Primary efficacy endpoint was reached in 100% of patients for PVI, PW and additional lesions (Figure 1). First Pass Isolation rate was 96.2% for PVI (LSPV: 100%; LIPV: 93.5%; RSPV: 90.1%; RIPV: 96.9%) and 80% for PW isolation (Figure 1). The integrated VLCC electroanatomic mapping system allowed mapping of 4 different atrial tachycardias (1 double loop AFL, 2 CTI-dependent AFL and 1 crista terminalis atrial tachycardia). No safety endpoint occurred. Conclusions AF ablation via a novel VLCC confirmed high efficacy and safety in a real-world scenario.

Authors

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.170
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-world experience of atrial fibrillation ablation using a variable-loop circular catheter: a single-centre study

C De Asmundis, Vedran Pašara, G Vetta, G Bala et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Real-world experience of atrial fibrillation ablation using a variable-loop circular catheter: a single-centre study

C De Asmundis, Vedran Pašara, G Vetta, G Bala, Della Rocca, E Stroker, L Marcon, A Almorad, Kazutaka Nakasone, Tommaso Sattin, Charles Audiat, J Sieira, Luigi Pannone, Andrea Sarkozy, G B Chierchia
article en

Abstract

Abstract Background The Variable-Loop Circular Catheter (VLCC) is a bidirectional multi-electrode catheter capable of electroanatomical mapping and pulsed field energy (PF) delivery for the treatment of atrial fibrillation (AF). Objective to report first experience with VLCC for AF ablation in a high-volume centre experienced with single-shot PF devices. Methods Consecutive AF patients undergoing AF ablation with VLCC were prospectively enrolled in our centre between April 2024 and October 2024. Pulmonary vein isolation (PVI) was performed using at least 16 applications per vein. The primary efficacy endpoint included acute electrical isolation of pulmonary veins (PVs) or posterior wall (PW) and bidirectional block in case of linear lesions. The primary safety endpoint was composite of periprocedural device-related major adverse events. Results We enrolled 32 (63.6 ± 10.2 years, 50% males, 28.1% Persistent AF) patients and a total of 130 PVs. All patients underwent PVI, 31.3% underwent PW isolation and 9.4% underwent additional lesions with VLCC (1 Cavotricuspid isthmus, 1 roof line and 1 anterior mitral line ablation). In 34.4% of the patients, deflectable sheath was used, while in the remaining 65.6% patients a fixed sheath was employed. Median procedural time was 60 min (50-90), dwelling time 30 min (25-50) and fluoroscopy time 5 min (3-10). Primary efficacy endpoint was reached in 100% of patients for PVI, PW and additional lesions (Figure 1). First Pass Isolation rate was 96.2% for PVI (LSPV: 100%; LIPV: 93.5%; RSPV: 90.1%; RIPV: 96.9%) and 80% for PW isolation (Figure 1). The integrated VLCC electroanatomic mapping system allowed mapping of 4 different atrial tachycardias (1 double loop AFL, 2 CTI-dependent AFL and 1 crista terminalis atrial tachycardia). No safety endpoint occurred. Conclusions AF ablation via a novel VLCC confirmed high efficacy and safety in a real-world scenario.

EP EuropaceVol. 27(Supplement_1)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.