The impact of atrial dilatation on conduction heterogeneity at bachmann's bundle

Abstract Background Atrial fibrillation (AF) occurs more frequently in patients with atrial dilatation. Especially conduction disorders at Bachmann’s bundle (BB) are thought to contribute to the development of AF. BB is a muscular bundle and the main route of conduction between the left atrium and the right atrium. Since the fibers of BB are not wrapped in a layer of fibrous tissue, volume overload in the left or right atrium can increase stretch on BB, potentially disrupting these fibers. However, the effect of atrial dilatation on the presence and severity of conduction disorders at BB is still unknown. Purpose To determine the effect of atrial dilatation on conduction heterogeneity at BB during sinus rhythm. Methods High-resolution epicardial mapping (192 electrodes; interelectrode distance 2 mm) at BB was performed in 132 patients without a history of AF undergoing elective open heart surgery. Inter-electrode conduction times (CTs) were used to construct the relative frequency distribution histograms and analyze the 5th percentile and maximum CT. Conduction delay (CD) was defined as CT differences of 7 to 11 ms and conduction block (CB) as CT≥12 ms. The amount, number and maximum length of lines of CD, CB and CDCB were analyzed. Signal morphology was analyzed, with fractionation being classified into 4 categories: singles (one deflection), short doubles (two deflections with a distance <15 ms), long doubles (two deflections with a distance ≥15 ms) and complex (≥ 3 deflections). The left atrial volume index (LAVI) and right atrial volume index (RAVI) of all patients were determined from preoperative echocardiographic recordings using the body surface area (BSA) and the Biplane Area-Length Method for LAVI and the Single Plane Area-Length method for RAVI. All data were analyzed in a linear regression. Skewed data were modified into a normal distribution using a log-transformation. Results Conduction parameters, unipolar voltages and fractionation at BB were not significantly associated with the LAVI (p≥0.05). For the right atrium, an increasing RAVI was significantly associated with less single potentials (β = -0.216; p = 0.025) and more short double potentials (β = 0.201; p = 0.034). Other potential morphology parameters (long double-, complex fractionated potentials), as well as conduction parameters and unipolar voltages did not show a significant association with the RAVI (p≥0.05). Conclusion There was a limited effect of right atrial dilatation on the amount of conduction disorders at BB and no effect of left atrial dilatation any of the conduction parameters. These findings imply that atrial dilatation has no direct effect on conduction at BB.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.259
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of atrial dilatation on conduction heterogeneity at bachmann's bundle

Natasja M.S. de Groot, Yannick J.H.J. Taverne, Annejet Heida, Mathijs S. van Schie et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

The impact of atrial dilatation on conduction heterogeneity at bachmann's bundle

Natasja M.S. de Groot, Yannick J.H.J. Taverne, Annejet Heida, Mathijs S. van Schie, Danny Veen, M H C Linderhof, Anouk I. Freriks
article en

Abstract

Abstract Background Atrial fibrillation (AF) occurs more frequently in patients with atrial dilatation. Especially conduction disorders at Bachmann’s bundle (BB) are thought to contribute to the development of AF. BB is a muscular bundle and the main route of conduction between the left atrium and the right atrium. Since the fibers of BB are not wrapped in a layer of fibrous tissue, volume overload in the left or right atrium can increase stretch on BB, potentially disrupting these fibers. However, the effect of atrial dilatation on the presence and severity of conduction disorders at BB is still unknown. Purpose To determine the effect of atrial dilatation on conduction heterogeneity at BB during sinus rhythm. Methods High-resolution epicardial mapping (192 electrodes; interelectrode distance 2 mm) at BB was performed in 132 patients without a history of AF undergoing elective open heart surgery. Inter-electrode conduction times (CTs) were used to construct the relative frequency distribution histograms and analyze the 5th percentile and maximum CT. Conduction delay (CD) was defined as CT differences of 7 to 11 ms and conduction block (CB) as CT≥12 ms. The amount, number and maximum length of lines of CD, CB and CDCB were analyzed. Signal morphology was analyzed, with fractionation being classified into 4 categories: singles (one deflection), short doubles (two deflections with a distance <15 ms), long doubles (two deflections with a distance ≥15 ms) and complex (≥ 3 deflections). The left atrial volume index (LAVI) and right atrial volume index (RAVI) of all patients were determined from preoperative echocardiographic recordings using the body surface area (BSA) and the Biplane Area-Length Method for LAVI and the Single Plane Area-Length method for RAVI. All data were analyzed in a linear regression. Skewed data were modified into a normal distribution using a log-transformation. Results Conduction parameters, unipolar voltages and fractionation at BB were not significantly associated with the LAVI (p≥0.05). For the right atrium, an increasing RAVI was significantly associated with less single potentials (β = -0.216; p = 0.025) and more short double potentials (β = 0.201; p = 0.034). Other potential morphology parameters (long double-, complex fractionated potentials), as well as conduction parameters and unipolar voltages did not show a significant association with the RAVI (p≥0.05). Conclusion There was a limited effect of right atrial dilatation on the amount of conduction disorders at BB and no effect of left atrial dilatation any of the conduction parameters. These findings imply that atrial dilatation has no direct effect on conduction at BB.

EP EuropaceVol. 27(Supplement_1)
Erasmus University Rotterdam (NL)
Netherlands Heart Institute
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.