Optimal image intensity ratio threshold for atrial focal monopolar pulsed field ablation lesions assessment by dark-blood late gadolinium enhancement cardiac magnetic resonance imaging

Abstract Background Dark-blood late gadolinium enhancement cardiac magnetic resonance imaging (LGE CMR) has been used to assess ablation lesions after pulmonary vein isolation (PVI) by thermal energy sources (cryo and radiofrequency) with an optimal image intensity ratio (IIR) threshold of 1.09. However, the performance of dark-blood LGE MRI in assessing ablation lesions after PVI by monopolar biphasic focal pulsed field ablation (F-PFA) remains unclear. Purpose To determine the optimal IIR threshold for assessing F-PFA PVI lesions in dark-blood LGE MRI scans. Methods In eighteen patients, a 3D dark-blood LGE MRI was performed at 3 months after an initial PVI with F-PFA. Left atrial (LA) LGE MRIs were segmented using ADAS-AF, and electro-anatomical maps (EAM) obtained during the initial ablation procedure were analysed offline using custom-made software in MATLAB 2022b. After automatic alignment of both LA anatomies carefully excluding the pulmonary veins, LA appendage, and mitral valve annulus, the F-PFA location tags were projected onto the CMR anatomy. All CMR data points within a 5mm radius of each F-PFA location tags were treated as ‘ablation region’, while all points >5mm radius from a F-PFA location tags were treated as non-ablated regions. To maintain an equal ratio of ablated to non-ablated tissue, the same number of points as in the ablated region was randomly selected from the non-ablated region. Receiver operating characteristics (ROC) analyses were conducted to determine the area under the ROC curve (AUC) and the optimal IIR threshold for detection of the ablation scar. Average IIR values, AUC and optimal thresholds are determined for each patient. All values are reported are median and ranges [min-max] of these patient-specific values. Results One patient was excluded from analysis due to a technical error during EAM export. The ablated region in the remaining seventeen patients consisted of a median of 3783 [1283-4568] IIR points. The median IIR of the ablated and non-ablated region was 1.14 [1.06-1.30] and 1.06 [0.98-1.10] respectively (Figure, top). A clear difference in IIR values between ablated and non-ablated tissue was seen for all but two patients. ROC analysis achieved a median AUC of 0.77 [0.44-0.88] to distinguish between F-PFA locations and non-ablated tissue (Figure, bottom left), with an average optimal IIR threshold of 1.10 [1.06-1.36]. Conclusion Dark blood LGE MRI can visualize LA F-PFA lesions. An IIR threshold of 1.10 is identified as the optimal IIR threshold for distinguishing F-PFA locations from non-ablated tissue. This threshold closely aligns with the previously reported optimal IIR threshold for ablation lesions using thermal energy sources. Whether dark blood LGE MRI can identify local electrical reconnection sites after F-PFA PVI needs to be investigated in larger studies.Figure 1

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.388
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal image intensity ratio threshold for atrial focal monopolar pulsed field ablation lesions assessment by dark-blood late gadolinium enhancement cardiac magnetic resonance imaging

S M Chaldoupi, Kezia Jerltorp, Casper Mihl, Geertruida P. Bijvoet et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Optimal image intensity ratio threshold for atrial focal monopolar pulsed field ablation lesions assessment by dark-blood late gadolinium enhancement cardiac magnetic resonance imaging

S M Chaldoupi, Kezia Jerltorp, Casper Mihl, Geertruida P. Bijvoet, Ulrich Schotten, Kevin Vernooy, B J M Hermans, Frédéric Farnir, Dominik Linz, Bjørn Strøier Larsen, Robert J. Holtackers, J G L M Luermans
article en

Abstract

Abstract Background Dark-blood late gadolinium enhancement cardiac magnetic resonance imaging (LGE CMR) has been used to assess ablation lesions after pulmonary vein isolation (PVI) by thermal energy sources (cryo and radiofrequency) with an optimal image intensity ratio (IIR) threshold of 1.09. However, the performance of dark-blood LGE MRI in assessing ablation lesions after PVI by monopolar biphasic focal pulsed field ablation (F-PFA) remains unclear. Purpose To determine the optimal IIR threshold for assessing F-PFA PVI lesions in dark-blood LGE MRI scans. Methods In eighteen patients, a 3D dark-blood LGE MRI was performed at 3 months after an initial PVI with F-PFA. Left atrial (LA) LGE MRIs were segmented using ADAS-AF, and electro-anatomical maps (EAM) obtained during the initial ablation procedure were analysed offline using custom-made software in MATLAB 2022b. After automatic alignment of both LA anatomies carefully excluding the pulmonary veins, LA appendage, and mitral valve annulus, the F-PFA location tags were projected onto the CMR anatomy. All CMR data points within a 5mm radius of each F-PFA location tags were treated as ‘ablation region’, while all points >5mm radius from a F-PFA location tags were treated as non-ablated regions. To maintain an equal ratio of ablated to non-ablated tissue, the same number of points as in the ablated region was randomly selected from the non-ablated region. Receiver operating characteristics (ROC) analyses were conducted to determine the area under the ROC curve (AUC) and the optimal IIR threshold for detection of the ablation scar. Average IIR values, AUC and optimal thresholds are determined for each patient. All values are reported are median and ranges [min-max] of these patient-specific values. Results One patient was excluded from analysis due to a technical error during EAM export. The ablated region in the remaining seventeen patients consisted of a median of 3783 [1283-4568] IIR points. The median IIR of the ablated and non-ablated region was 1.14 [1.06-1.30] and 1.06 [0.98-1.10] respectively (Figure, top). A clear difference in IIR values between ablated and non-ablated tissue was seen for all but two patients. ROC analysis achieved a median AUC of 0.77 [0.44-0.88] to distinguish between F-PFA locations and non-ablated tissue (Figure, bottom left), with an average optimal IIR threshold of 1.10 [1.06-1.36]. Conclusion Dark blood LGE MRI can visualize LA F-PFA lesions. An IIR threshold of 1.10 is identified as the optimal IIR threshold for distinguishing F-PFA locations from non-ablated tissue. This threshold closely aligns with the previously reported optimal IIR threshold for ablation lesions using thermal energy sources. Whether dark blood LGE MRI can identify local electrical reconnection sites after F-PFA PVI needs to be investigated in larger studies.Figure 1

EP EuropaceVol. 27(Supplement_1)
University of Copenhagen (DK), University Medical Center (US), Cardiovascular Institute Hospital (JP), Maastricht University (NL)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.