Predictors of syncope recurrence in reflex syncope patients with dual-chamber pacemakers with anti-reflex functionality

Abstract Background Dual-chamber pacemakers with anti-reflex syncope functionality have demonstrated efficacy in managing reflex syncope; however, a subset of patients still experiences recurrent episodes post-implantation. Furthermore, indications for pacemaker implantation in patients younger than 40 years and those with mixed-type responses to tilt-table testing remain uncertain due to limited evidence. This study aimed to evaluate the efficacy of dual-chamber pacemakers with anti-reflex syncope functionality and identify predictors of recurrent syncope in this specific patient population. Methods This study included patients with reflex syncope who had positive tilt-table test results and a clinical indication for dual-chamber pacemaker with anti-reflex syncope functionality. Patients were followed for 6 months post-implantation, with data collected on vital signs during tilt-table testing, pacemaker efficacy in preventing syncope recurrence, and an analysis of risk factor analysis for recurrent syncope. Results Among the cohort of 117 patients, 65% were female, with a mean age of 47.9 ± 15.1 years. Type 1 (mixed type) accounted for 25.6% of cases (30 patients), while type 2B was the most common, comprising 66.7% of the population. After 6 months, the recurrence rate was 12.8% (15/117). Cox multivariate regression analysis identified independent predictors of recurrence, including an asystole duration ≥ 13.5 seconds on tilt-table testing (hazard ratio [HR]: 20.2, 95% confidence interval [CI]: 2.009–202.307, p = 0.011), a pre-implantation syncope frequency ≥ 2.5 episodes (HR: 4.9, 95% CI: 1.089–22.536, p = 0.038), and a systolic blood pressure differential ≥ 102.5 mmHg between the end of the passive phase and syncope onset (HR: 5.1, 95% CI: 1.368–19.349, p = 0.015). In subgroup analysis, patients with mixed-type responses showed a significantly higher systolic blood pressure between the end of the passive phase and syncope onset differential in those with recurrence compared to non-recurrence (98.6 ± 15.6 mmHg vs. 80.2 ± 12.1 mmHg; p = 0.002). Conclusions Dual-chamber pacemakers with anti-reflex functionality effectively reduce recurrence rates in patients with reflex syncope, achieving a recurrence rate of 12.8% at 6 months. Independent predictors of recurrent syncope include an asystole duration ≥ 13.5 seconds, a pre-implantation episode frequency ≥ 2.5, and a systolic blood pressure differential ≥ 102.5 mmHg between the end of the passive phase and syncope onset, especially significant in patients with mixed-type responses. These findings support the use of pacemaker therapy in high-risk reflex syncope patients.Syncope Recurrence Characteristics Kaplan-Meier Asystole time

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.244
Primary Topic
Cardiovascular Syncope and Autonomic Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictors of syncope recurrence in reflex syncope patients with dual-chamber pacemakers with anti-reflex functionality

Pham Uyen, Daniel Vo, Dung Kieu Ngoc, Dat Tran Cao et al.
EP Europace
Cardiovascular Syncope and Autonomic Disorders
article

Predictors of syncope recurrence in reflex syncope patients with dual-chamber pacemakers with anti-reflex functionality

Pham Uyen, Daniel Vo, Dung Kieu Ngoc, Dat Tran Cao, Thuc Nguyen Tri
article en

Abstract

Abstract Background Dual-chamber pacemakers with anti-reflex syncope functionality have demonstrated efficacy in managing reflex syncope; however, a subset of patients still experiences recurrent episodes post-implantation. Furthermore, indications for pacemaker implantation in patients younger than 40 years and those with mixed-type responses to tilt-table testing remain uncertain due to limited evidence. This study aimed to evaluate the efficacy of dual-chamber pacemakers with anti-reflex syncope functionality and identify predictors of recurrent syncope in this specific patient population. Methods This study included patients with reflex syncope who had positive tilt-table test results and a clinical indication for dual-chamber pacemaker with anti-reflex syncope functionality. Patients were followed for 6 months post-implantation, with data collected on vital signs during tilt-table testing, pacemaker efficacy in preventing syncope recurrence, and an analysis of risk factor analysis for recurrent syncope. Results Among the cohort of 117 patients, 65% were female, with a mean age of 47.9 ± 15.1 years. Type 1 (mixed type) accounted for 25.6% of cases (30 patients), while type 2B was the most common, comprising 66.7% of the population. After 6 months, the recurrence rate was 12.8% (15/117). Cox multivariate regression analysis identified independent predictors of recurrence, including an asystole duration ≥ 13.5 seconds on tilt-table testing (hazard ratio [HR]: 20.2, 95% confidence interval [CI]: 2.009–202.307, p = 0.011), a pre-implantation syncope frequency ≥ 2.5 episodes (HR: 4.9, 95% CI: 1.089–22.536, p = 0.038), and a systolic blood pressure differential ≥ 102.5 mmHg between the end of the passive phase and syncope onset (HR: 5.1, 95% CI: 1.368–19.349, p = 0.015). In subgroup analysis, patients with mixed-type responses showed a significantly higher systolic blood pressure between the end of the passive phase and syncope onset differential in those with recurrence compared to non-recurrence (98.6 ± 15.6 mmHg vs. 80.2 ± 12.1 mmHg; p = 0.002). Conclusions Dual-chamber pacemakers with anti-reflex functionality effectively reduce recurrence rates in patients with reflex syncope, achieving a recurrence rate of 12.8% at 6 months. Independent predictors of recurrent syncope include an asystole duration ≥ 13.5 seconds, a pre-implantation episode frequency ≥ 2.5, and a systolic blood pressure differential ≥ 102.5 mmHg between the end of the passive phase and syncope onset, especially significant in patients with mixed-type responses. These findings support the use of pacemaker therapy in high-risk reflex syncope patients.Syncope Recurrence Characteristics Kaplan-Meier Asystole time

EP EuropaceVol. 27(Supplement_1)
Cho Ray Hospital (VN)
Openalex Percentile: Top 80%
Cardiovascular Syncope and Autonomic Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.