Temporal analysis of intracardiac electrograms during pulsed-field ablation

Abstract Background Pulsed-field ablation (PFA) aims to treat atrial fibrillation (AF) by the irreversible electrical elimination of the myocardial cells around the pulmonary veins (PV). However, interpretation of the local electrograms (EGMs) from the large 2mm electrodes of the catheter remains challenging. Purpose To characterize the local EGMs recorded by the ablation catheter, assess their changes with PFA applications, and evaluate lesion efficacy. Method We included 32 consecutive patients referred for AF catheter ablation. The pentaspline catheter (Farawave, Boston Scientific) was positioned in basket configuration at the PV ostium. Lesion efficacy was assessed by pacing between the electrodes at three time points: before the first double-pulse application, before the second application following a 30° rotation, and after a 60 sec waiting period (Figure). All EGMs were analyzed for bipolar voltage amplitude and frequency composition using FFT. A frequency cut-off at 50 Hz was applied to calculate the power of the high frequency band (HF50). Results We analyzed 103 applications resulting in 309 epoch and 1545 EGMs. Median voltage and HF50 before first application package were 1.24 mV and 1466 µV^2, respectively, and before second application after rotation of the catheter 0.137 mV and 13 µV^2, respectively (Figure, pink line) with a high interindividual variation. These values remain constant over 60 sec waiting period. Lack of pace-capture can be predicted by a voltage threshold of 0.41mV (accuracy=0.891, sensitivity=0.817, specificity=0.926) and an HF50 threshold of 61.4µV^2 (accuracy=0.883, sensitivity=0.881, specificity=0.884). Conclusion Signal reduction was most pronounced after first application. While the maximal voltage amplitude was comparable to other multipolar diagnostic catheters, the median minimal voltage was >0.1mV. Given the pace-capture threshold of 0.41 mV, a lower scar cutoff between 0.1mV and 0.4mV might be advisable, but this needs further investigation.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.168
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temporal analysis of intracardiac electrograms during pulsed-field ablation

Philipp Krisai, Thomas Kueffer, Bill Subin, Angela De Luca et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Temporal analysis of intracardiac electrograms during pulsed-field ablation

Philipp Krisai, Thomas Kueffer, Bill Subin, Angela De Luca, Vincent Schlageter, Michael Kühne, Patrick Badertscher, Sven Knecht, Christian Sticherling, David Spreen, N Schaerli
article en

Abstract

Abstract Background Pulsed-field ablation (PFA) aims to treat atrial fibrillation (AF) by the irreversible electrical elimination of the myocardial cells around the pulmonary veins (PV). However, interpretation of the local electrograms (EGMs) from the large 2mm electrodes of the catheter remains challenging. Purpose To characterize the local EGMs recorded by the ablation catheter, assess their changes with PFA applications, and evaluate lesion efficacy. Method We included 32 consecutive patients referred for AF catheter ablation. The pentaspline catheter (Farawave, Boston Scientific) was positioned in basket configuration at the PV ostium. Lesion efficacy was assessed by pacing between the electrodes at three time points: before the first double-pulse application, before the second application following a 30° rotation, and after a 60 sec waiting period (Figure). All EGMs were analyzed for bipolar voltage amplitude and frequency composition using FFT. A frequency cut-off at 50 Hz was applied to calculate the power of the high frequency band (HF50). Results We analyzed 103 applications resulting in 309 epoch and 1545 EGMs. Median voltage and HF50 before first application package were 1.24 mV and 1466 µV^2, respectively, and before second application after rotation of the catheter 0.137 mV and 13 µV^2, respectively (Figure, pink line) with a high interindividual variation. These values remain constant over 60 sec waiting period. Lack of pace-capture can be predicted by a voltage threshold of 0.41mV (accuracy=0.891, sensitivity=0.817, specificity=0.926) and an HF50 threshold of 61.4µV^2 (accuracy=0.883, sensitivity=0.881, specificity=0.884). Conclusion Signal reduction was most pronounced after first application. While the maximal voltage amplitude was comparable to other multipolar diagnostic catheters, the median minimal voltage was >0.1mV. Given the pace-capture threshold of 0.41 mV, a lower scar cutoff between 0.1mV and 0.4mV might be advisable, but this needs further investigation.

EP EuropaceVol. 27(Supplement_1)
University Hospital of Bern (CH), Centre Hospitalier Universitaire Vaudois (CH)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.