The potential role of vectorcardiographic QRS-area in determining capture type in left bundle branch area pacing

Abstract Background Confirming conduction system capture during left bundle branch area pacing (LBBAP) primarily relies on ECG criteria obtained at the time of implantation. Post-implant ECG interpretation, however, is often subjective to clinical variability. In this context, objective and more quantitative parameters could aid implanting cardiologists in identifying LBBAP capture. Purpose To investigate the potential role of vectorcardiographic QRS-area in identifying capture type during LBBAP, compared to clinical judgment. Methods Unipolar paced ECGs during LBBAP implantation from 48 patients with preserved ejection fraction and baseline narrow QRS were collected. Conduction system capture was attempted in all patients and assessed using QRS morphology transitions during threshold testing following the EHRA 2023 consensus statement (gold standard). Eight experienced LBBAP-implanting cardiologists from six tertiary referral centers were asked to classify the ECGs into capture types. The vectorcardiographic QRS area was calculated from the synthesized vectorcardiogram using the Kors transformation matrix, with custom-developed code programmed in MATLAB. The accuracy of QRS area in differentiating left ventricular septal pacing (LVSP) from non-selective (nsLBBP), compared to clinical judgment of each individual observer, was evaluated using sensitivity, specificity, and accuracy analyses. Differences between QRS-area and QRS duration between LVSP and nsLBBP were assessed with Mann-Whitney U tests. Results QRS area was significantly higher for LVSP than for nsLBBP (LVSP median: 38, range 28–49; nsLBBP median: 22, range 15–28; p <0.001). QRS duration (determined from onset stimulus) was not significantly different between LVSP and nsLBBP (LVSP median: 133, range 125–143; nsLBBP median: 131, range 110–141; p <0.108). A cutoff point of 26 mV.ms (determined from ROC curves) for QRS-area yielded a sensitivity of 81%, specificity of 69%, and accuracy of 77% for distinguishing LVSP from nsLBBP. Clinical judgement of the 8 observers yielded an average sensitivity of 82% (range 71-100%), specificity of 64% (range 52-85%), and accuracy of 72% (range 62-78%). An overview of the accompanying sensitivity and specificity analyses is provided in the figure. Conclusion Vectorcardiographic QRS-area is a promising parameter for distinguishing LVSP from nsLBBP. Its ability to differentiate capture types slightly outperforms clinical judgment of experienced cardiologists and may serve as a valuable quantitative adjunct to clinical assessment, enhancing the accuracy of conduction system capture determination during LBBAP.Accuracy analyses

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.816
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The potential role of vectorcardiographic QRS-area in determining capture type in left bundle branch area pacing

Edoardo Bressi, Uyên Châu Nguyên, Jesse Rijks, Leonard M. Rademakers et al.
EP Europace
Cardiac pacing and defibrillation studies
article

The potential role of vectorcardiographic QRS-area in determining capture type in left bundle branch area pacing

Edoardo Bressi, Uyên Châu Nguyên, Jesse Rijks, Leonard M. Rademakers, Karol Čurila, Kevin Vernooy, Domenico Grieco, Johan van Koll, Haran Burri, Kim M. Smits, Jacqueline E. Joza, Sander M. J. van Kuijk, Justin Luermans
article en

Abstract

Abstract Background Confirming conduction system capture during left bundle branch area pacing (LBBAP) primarily relies on ECG criteria obtained at the time of implantation. Post-implant ECG interpretation, however, is often subjective to clinical variability. In this context, objective and more quantitative parameters could aid implanting cardiologists in identifying LBBAP capture. Purpose To investigate the potential role of vectorcardiographic QRS-area in identifying capture type during LBBAP, compared to clinical judgment. Methods Unipolar paced ECGs during LBBAP implantation from 48 patients with preserved ejection fraction and baseline narrow QRS were collected. Conduction system capture was attempted in all patients and assessed using QRS morphology transitions during threshold testing following the EHRA 2023 consensus statement (gold standard). Eight experienced LBBAP-implanting cardiologists from six tertiary referral centers were asked to classify the ECGs into capture types. The vectorcardiographic QRS area was calculated from the synthesized vectorcardiogram using the Kors transformation matrix, with custom-developed code programmed in MATLAB. The accuracy of QRS area in differentiating left ventricular septal pacing (LVSP) from non-selective (nsLBBP), compared to clinical judgment of each individual observer, was evaluated using sensitivity, specificity, and accuracy analyses. Differences between QRS-area and QRS duration between LVSP and nsLBBP were assessed with Mann-Whitney U tests. Results QRS area was significantly higher for LVSP than for nsLBBP (LVSP median: 38, range 28–49; nsLBBP median: 22, range 15–28; p <0.001). QRS duration (determined from onset stimulus) was not significantly different between LVSP and nsLBBP (LVSP median: 133, range 125–143; nsLBBP median: 131, range 110–141; p <0.108). A cutoff point of 26 mV.ms (determined from ROC curves) for QRS-area yielded a sensitivity of 81%, specificity of 69%, and accuracy of 77% for distinguishing LVSP from nsLBBP. Clinical judgement of the 8 observers yielded an average sensitivity of 82% (range 71-100%), specificity of 64% (range 52-85%), and accuracy of 72% (range 62-78%). An overview of the accompanying sensitivity and specificity analyses is provided in the figure. Conclusion Vectorcardiographic QRS-area is a promising parameter for distinguishing LVSP from nsLBBP. Its ability to differentiate capture types slightly outperforms clinical judgment of experienced cardiologists and may serve as a valuable quantitative adjunct to clinical assessment, enhancing the accuracy of conduction system capture determination during LBBAP.Accuracy analyses

EP EuropaceVol. 27(Supplement_1)
Radboud University Nijmegen (NL), Charles University (CZ), Catharina Ziekenhuis (NL), McGill University Health Centre (CA), University Medical Center (US), Cardiovascular Institute Hospital (JP), Maastricht University (NL), Policlinico Casilino (IT), Geneva College (US)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.