Optimal power settings have major impact on procedural efficiency in pulmonary vein isolation guided by robotic magnetic navigation

Abstract Introduction Early reports on pulmonary vein isolation (PVI) for atrial fibrillation (AF) guided by robotic magnetic navigation (RMN) show comparable results to manual radiofrequency (RF) or cryoballoon ablation, however lengthy procedures were reported. This could be due to suboptimal lesion formation caused by a lack of user experience and defined best practices. Operators performed RMN-guided RF ablation with lower power settings, presumably leading to longer procedures. In this study, we aimed to re- evaluate safety and efficiency of RMN-guided PVI for AF based on delivered radiofrequency power. Methods Patients undergoing RMN-guided ablation were screened, and consecutive patients with AF undergoing PVI-only between 2008 and 2023 were enrolled. Patients were grouped by the power settings utilized during the PVI procedure (group 1 – 25-30W, group 2 – 30-35W, group 3 – 35-40W, group 4 – 40-45W, group 5 – 45-50W, group 6 – 50-55W). We collected and analysed demographic data: age, sex, AF type; safety data: intra- and post-procedural complications; procedural data: procedure duration, fluoroscopy time, RF ablation time, RF application number, success rate; and follow-up data: AF recurrence and number of redo procedures. Results From the total number of 3398 screened patients, 238 patients met the inclusion criterium of undergoing PVI-only procedure (mean age 60.4 ± 9.9 years, 63.8% male). Throughout the 15 years only five patients had major (2.2%) and 15 patients had minor complications (6.6%), without differences between the patient groups (p = 0.40, and p = 0.63). The mean procedure duration was progressively decreased with the use of higher RF power (273.9±97.0, 179.8±104.0, 134.9±55.3, 134.0±39.5, 118.1±41.3, 110.9±39.0 minutes, respectively, p < 0.001). Median fluoroscopy time was 19.5 (IQR 13.0 – 35.5) minutes, progressively decreasing within the power groups (58.2±20.5, 40.5± 26.2, 15.9±6.6, 17.8±8.1, 17.4±7.5, 19.8±9.3 minutes, p < 0.001). We found differences between the power groups in RF application number (p < 0.001) and RF application duration (p = 0.003). Successful PVI was achieved in 238 patients (100.0%). Twenty-one patients with paroxysmal AF (17.1%) and 31 patients with persistent AF (40.7%) had documented recurrence during the 12-months follow-up. We found no differences in AF recurrence between the patient groups (p = 0.18 and 0.66). Conclusions RMN-guided PVI-only for AF is safe and feasible. In contrast to early reports, procedure times and fluoroscopy use gradually decreased during the years, when increasing RF power was applied. Higher power settings during robotically-guided PVI did not compromise the safety of the procedures.Technological advancements

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.189
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal power settings have major impact on procedural efficiency in pulmonary vein isolation guided by robotic magnetic navigation

R Gagyi, Tamás Szili‐Törok, I A Minciuna, Attila Nemes
EP Europace
Congenital Heart Disease Studies
article

Optimal power settings have major impact on procedural efficiency in pulmonary vein isolation guided by robotic magnetic navigation

R Gagyi, Tamás Szili‐Törok, I A Minciuna, Attila Nemes
article en

Abstract

Abstract Introduction Early reports on pulmonary vein isolation (PVI) for atrial fibrillation (AF) guided by robotic magnetic navigation (RMN) show comparable results to manual radiofrequency (RF) or cryoballoon ablation, however lengthy procedures were reported. This could be due to suboptimal lesion formation caused by a lack of user experience and defined best practices. Operators performed RMN-guided RF ablation with lower power settings, presumably leading to longer procedures. In this study, we aimed to re- evaluate safety and efficiency of RMN-guided PVI for AF based on delivered radiofrequency power. Methods Patients undergoing RMN-guided ablation were screened, and consecutive patients with AF undergoing PVI-only between 2008 and 2023 were enrolled. Patients were grouped by the power settings utilized during the PVI procedure (group 1 – 25-30W, group 2 – 30-35W, group 3 – 35-40W, group 4 – 40-45W, group 5 – 45-50W, group 6 – 50-55W). We collected and analysed demographic data: age, sex, AF type; safety data: intra- and post-procedural complications; procedural data: procedure duration, fluoroscopy time, RF ablation time, RF application number, success rate; and follow-up data: AF recurrence and number of redo procedures. Results From the total number of 3398 screened patients, 238 patients met the inclusion criterium of undergoing PVI-only procedure (mean age 60.4 ± 9.9 years, 63.8% male). Throughout the 15 years only five patients had major (2.2%) and 15 patients had minor complications (6.6%), without differences between the patient groups (p = 0.40, and p = 0.63). The mean procedure duration was progressively decreased with the use of higher RF power (273.9±97.0, 179.8±104.0, 134.9±55.3, 134.0±39.5, 118.1±41.3, 110.9±39.0 minutes, respectively, p < 0.001). Median fluoroscopy time was 19.5 (IQR 13.0 – 35.5) minutes, progressively decreasing within the power groups (58.2±20.5, 40.5± 26.2, 15.9±6.6, 17.8±8.1, 17.4±7.5, 19.8±9.3 minutes, p < 0.001). We found differences between the power groups in RF application number (p < 0.001) and RF application duration (p = 0.003). Successful PVI was achieved in 238 patients (100.0%). Twenty-one patients with paroxysmal AF (17.1%) and 31 patients with persistent AF (40.7%) had documented recurrence during the 12-months follow-up. We found no differences in AF recurrence between the patient groups (p = 0.18 and 0.66). Conclusions RMN-guided PVI-only for AF is safe and feasible. In contrast to early reports, procedure times and fluoroscopy use gradually decreased during the years, when increasing RF power was applied. Higher power settings during robotically-guided PVI did not compromise the safety of the procedures.Technological advancements

EP EuropaceVol. 27(Supplement_1)
Iuliu Hațieganu University of Medicine and Pharmacy (RO), University of Szeged (HU)
Openalex Percentile: Top 83%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.