Evaluating omnipolar configuration for complex fractionated atrial electrograms detection: a study in animal models

Abstract Introduction Atrial fibrillation (AF) is a global health concern, often treated with the ablation of certain tissue areas. The emergence of complex fractionated atrial electrograms (CFAEs) as a biomarker, associated with factors such as fibrosis, anisotropy or heterogeneous tissue activation, initially demonstrated high efficacy [1]. However, subsequent findings have shown variable results. Purpose This study aims to revalidate the criterion for detecting regions with CFAEs using omnipolar electrograms (oEGMs) and to compare this configuration with the traditional bipolar approach, which, due to its sensitivity to the direction of propagation, may yield low-amplitude and prolonged pulses that can be misinterpreted as CFAEs. Methods The data was collected from the left atrium of a female swine using a HD-Grid catheter (Figure 1). To assess the false-positive rate for both configurations, pre-ablated tissue was used. For this reason, the entire dataset of 400 recordings was filtered based on peak-to-peak amplitude (> 1.5 mV) and vector field heterogeneity [2] (VFH < 0.4). Thus, characterization was performed solely on healthy tissue. A total of 2666 bEGMs and their respective 1333 oEGMs were analyzed. For oEGMs acquisition, the bEGM cross approach was used [3]. A cross-correlation algorithm was then employed to classify each complex into distinct groups. This algorithm groups pulses based on a maximum cross-correlation greater than 0.95. Following the criteria for defining fractionation [1], each group was classified into one of two categories: normal or CFAE. Results Table 1 summarizes the results of the cross-correlation algorithm results obtained. The percentage of false positives for CFAEs identified in bEGMs (13.15%) is significantly higher than in oEGMs (3.32%), whose principle of amplitude maximization in the direction of propagation suppresses fractionation succesfully. Furthermore, the amplitude and duration ranges of the bEGMs confirms the initial hypothesis that low-amplitude and prolonged bEGMs are prone to misclassification as CFAEs. Examples of pulses from each high cross-correlation group illustrate accurate classification. Note that CFAE pulses exhibit a greater number of baseline-deflecting peaks and display a more complex morphology. Conclusions This study reports the limitations of bipolar configuration in identifying CFAE, particularly due to its sensitivity to propagation direction when classifying entirely healthy pulses. The omnipolar approach is proposed as it significantly enhances CFAE identification by reducing false positives fourfold, and providing a robust technique for assessing cardiac substrate in detecting ablation-suitable regions in AF patients.Figure 1:HD-Grid intracavitary catheter Table 1:Summary of the results

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.147
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating omnipolar configuration for complex fractionated atrial electrograms detection: a study in animal models

José Millet, Martin Pešl, Elisa Ramírez, Francisco Castells et al.
EP Europace
ECG Monitoring and Analysis
article

Evaluating omnipolar configuration for complex fractionated atrial electrograms detection: a study in animal models

José Millet, Martin Pešl, Elisa Ramírez, Francisco Castells, Zdeněk Stárek, Jakub Hejč, R Alós
article en

Abstract

Abstract Introduction Atrial fibrillation (AF) is a global health concern, often treated with the ablation of certain tissue areas. The emergence of complex fractionated atrial electrograms (CFAEs) as a biomarker, associated with factors such as fibrosis, anisotropy or heterogeneous tissue activation, initially demonstrated high efficacy [1]. However, subsequent findings have shown variable results. Purpose This study aims to revalidate the criterion for detecting regions with CFAEs using omnipolar electrograms (oEGMs) and to compare this configuration with the traditional bipolar approach, which, due to its sensitivity to the direction of propagation, may yield low-amplitude and prolonged pulses that can be misinterpreted as CFAEs. Methods The data was collected from the left atrium of a female swine using a HD-Grid catheter (Figure 1). To assess the false-positive rate for both configurations, pre-ablated tissue was used. For this reason, the entire dataset of 400 recordings was filtered based on peak-to-peak amplitude (> 1.5 mV) and vector field heterogeneity [2] (VFH < 0.4). Thus, characterization was performed solely on healthy tissue. A total of 2666 bEGMs and their respective 1333 oEGMs were analyzed. For oEGMs acquisition, the bEGM cross approach was used [3]. A cross-correlation algorithm was then employed to classify each complex into distinct groups. This algorithm groups pulses based on a maximum cross-correlation greater than 0.95. Following the criteria for defining fractionation [1], each group was classified into one of two categories: normal or CFAE. Results Table 1 summarizes the results of the cross-correlation algorithm results obtained. The percentage of false positives for CFAEs identified in bEGMs (13.15%) is significantly higher than in oEGMs (3.32%), whose principle of amplitude maximization in the direction of propagation suppresses fractionation succesfully. Furthermore, the amplitude and duration ranges of the bEGMs confirms the initial hypothesis that low-amplitude and prolonged bEGMs are prone to misclassification as CFAEs. Examples of pulses from each high cross-correlation group illustrate accurate classification. Note that CFAE pulses exhibit a greater number of baseline-deflecting peaks and display a more complex morphology. Conclusions This study reports the limitations of bipolar configuration in identifying CFAE, particularly due to its sensitivity to propagation direction when classifying entirely healthy pulses. The omnipolar approach is proposed as it significantly enhances CFAE identification by reducing false positives fourfold, and providing a robust technique for assessing cardiac substrate in detecting ablation-suitable regions in AF patients.Figure 1:HD-Grid intracavitary catheter Table 1:Summary of the results

EP EuropaceVol. 27(Supplement_1)
University Hospital Brno (CZ), St. Anne's University Hospital Brno (CZ), Universitat Politècnica de València (ES)
Ministerio de Ciencia e Innovación
Openalex Percentile: Top 79%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.