One-year outcomes after atrial fibrillation ablation with the novel lattice-tip catheter

Abstract Background A novel lattice-tip combined mapping and ablation catheter, capable of pulsed-field (PFA) and conventional radiofrequency (RF) ablation and fully integrated into a novel mapping and ablation platform, has been introduced. Information on long-term outcomes for a range of clinically used left and right atrial ablation targets is not yet fully available. Methods Consecutive patients undergoing first-time AF ablation using the new system at our center and with one-year follow-up were collected and analysed. AF ablation consisted of PFA-based pulmonary vein isolation and, based at the clinician's discretion, additional linear lesions (RF or PFA). All patients provided written informed consent and were enrolled in our prospective TRUST Registry. Results A total of 32 patients were analysed (11/32 (34%) women, median age 67.5 years (61.2–74.5), 16/32 (50%) persistent AF (Pers-AF), median left ventricular ejection fraction (LVEF) 60% (50.7–60)). Acute PVI with PFA only was achieved in 32/32 (100%) PVs with first pass isolation in 125/125 (100%) PVs. Median mapping time was 22.5 (16–28.2) minutes. Additional left atrial linear lesions were delivered in 19/32 (59%) patients, including 6 anterior lines (RF+PFA), 3 mitral isthmus lines (2/3 (66.6%) RF and 1/3 (33.3%) RF+PFA), 11 roof lines (PFA), and 1 posterior box (PFA). In 7/32 (21.9%) patients, cavo-tricuspid isthmus ablation was performed after documentation of typical atrial flutter. All the linear lesion sets were bidirectionally blocked at the end of the procedure. Mean procedure and fluoroscopy times were 100.8 ± 25.4 and 8.6 ± 3.8 minutes, respectively. Mean dose area product was 518.2 ± 433.9 cGycm2. Cumulative median ablation time was 5.85 (4.88–7.06) minutes and median number of lesions was 93.5 (78.5–105.2). Ablation-related complications occurred in 1/32 (3%) patients (1 cardiac tamponade). AF free survival after a median FU of 341 (236–360) days was 82.9% for paroxysmal AF (PAF) and 67.5% for Pers-AF (p value = 0.62). Conclusion Large focal-tip catheter-based ablation for AF appears safe and effective for a range of left and right atrial ablation targets with good rhythm outcomes at one-year follow-up.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.339
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-year outcomes after atrial fibrillation ablation with the novel lattice-tip catheter

L Rottner, Fabian Moser, M Lemoine, Andreas Rillig et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

One-year outcomes after atrial fibrillation ablation with the novel lattice-tip catheter

L Rottner, Fabian Moser, M Lemoine, Andreas Rillig, Philipp Kirchhoff, Ilaria My, M Nies, Andreas Metzner, Feifan Ouyang, Niklas Schenker, Bruno Reißmann, K Govorov, L Kraegefski
article en

Abstract

Abstract Background A novel lattice-tip combined mapping and ablation catheter, capable of pulsed-field (PFA) and conventional radiofrequency (RF) ablation and fully integrated into a novel mapping and ablation platform, has been introduced. Information on long-term outcomes for a range of clinically used left and right atrial ablation targets is not yet fully available. Methods Consecutive patients undergoing first-time AF ablation using the new system at our center and with one-year follow-up were collected and analysed. AF ablation consisted of PFA-based pulmonary vein isolation and, based at the clinician's discretion, additional linear lesions (RF or PFA). All patients provided written informed consent and were enrolled in our prospective TRUST Registry. Results A total of 32 patients were analysed (11/32 (34%) women, median age 67.5 years (61.2–74.5), 16/32 (50%) persistent AF (Pers-AF), median left ventricular ejection fraction (LVEF) 60% (50.7–60)). Acute PVI with PFA only was achieved in 32/32 (100%) PVs with first pass isolation in 125/125 (100%) PVs. Median mapping time was 22.5 (16–28.2) minutes. Additional left atrial linear lesions were delivered in 19/32 (59%) patients, including 6 anterior lines (RF+PFA), 3 mitral isthmus lines (2/3 (66.6%) RF and 1/3 (33.3%) RF+PFA), 11 roof lines (PFA), and 1 posterior box (PFA). In 7/32 (21.9%) patients, cavo-tricuspid isthmus ablation was performed after documentation of typical atrial flutter. All the linear lesion sets were bidirectionally blocked at the end of the procedure. Mean procedure and fluoroscopy times were 100.8 ± 25.4 and 8.6 ± 3.8 minutes, respectively. Mean dose area product was 518.2 ± 433.9 cGycm2. Cumulative median ablation time was 5.85 (4.88–7.06) minutes and median number of lesions was 93.5 (78.5–105.2). Ablation-related complications occurred in 1/32 (3%) patients (1 cardiac tamponade). AF free survival after a median FU of 341 (236–360) days was 82.9% for paroxysmal AF (PAF) and 67.5% for Pers-AF (p value = 0.62). Conclusion Large focal-tip catheter-based ablation for AF appears safe and effective for a range of left and right atrial ablation targets with good rhythm outcomes at one-year follow-up.

EP EuropaceVol. 27(Supplement_1)
Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.