Photon-counting ct evaluation of regional wall thickness and epicardial fat distribution in the left atrium

Abstract Background Achieving sufficient ablation lesions can be challenging, and it has long been suspected that wall thickness plays a significant role in this process, along with the potential influence of epicardial fat. Traditional imaging techniques with a high spatial resolution often lack the resolution necessary for accurate assessment of these anatomical features. The advent of Photon-Counting Computed Tomography (CT) enhances imaging capabilities, allowing for precise evaluation of wall thickness and epicardial fat distribution. Purpose The purpose of this study was to characterize wall thickness and epicardial fat of different regions in the LA with a photon-counting CT. Methods High-resolution photon-counting CT was performed pre-interventionally in 50 patients undergoing AF ablation as part of a prospective study. After processing the CT scans with the 3D segmentation software to measure wall thickness and epicardial fat thickness, the left atrium was segmented into six regions (anterior, roof, posterior, inferior, lateral, septal) using the Paraview 5.12.0 visualization program. For each region, the mean, median, and standard deviation of wall thickness and epicardial fat were calculated. Results The mean wall thickness (± standard deviation) and median with interquartile range (Q1–Q3) were observed in each region of the left atrium as follows: anterior: mean 1.79 ± 0.26 mm, median 1.80 [1.56–1.93] mm; roof: mean 1.58 ± 0.31 mm, median 1.55 [1.34–1.78] mm; posterior: mean 1.79 ± 0.32 mm, median 1.78 [1.57–2.08] mm; inferior: mean 1.74 ± 0.36 mm, median 1.69 [1.50–2.03] mm; lateral: mean 1.76 ± 0.36 mm, median 1.75 [1.51–1.97] mm; and septal: mean 1.81 ± 0.27 mm, median 1.77 [1.65–2.04] mm. Epicardial fat thickness showed notable regional variability, with mean (± standard deviation) and median with interquartile range as follows: anterior: mean 2.25 ± 0.88 mm, median 2.12 [1.64–2.84] mm; roof: mean 1.94 ± 1.23 mm, median 3.05 [0.93–2.89] mm; posterior: mean 0.23 ± 0.25 mm, median 0.12 [0.03–0.39] mm; inferior: mean 1.34 ± 0.88 mm, median 1.36 [0.67–1.95] mm; and lateral: mean 2.56 ± 1.17 mm, median 2.42 [1.82–3.15] mm. Conclusion This study provides a comprehensive evaluation of regional wall thickness and epicardial fat distribution in the left atrium using high-resolution photon-counting CT. Wall thickness is homogeneous within individual patients but shows significant heterogeneity between patients, highlighting the need for high-resolution imaging for accurate assessment. In contrast, epicardial fat distribution is highly heterogeneous within individual patients, particularly in the posterior region. These findings emphasize the importance of considering both regional variations in wall thickness and fat distribution when planning ablation strategies for atrial fibrillation, potentially improving procedural outcomes and patient management.segmented regions,wall thickness,epi fat mean wall thickness, epi fat per region

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.402
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-counting ct evaluation of regional wall thickness and epicardial fat distribution in the left atrium

Isabel Deisenhofer, Madeleine Tydecks, Theresa Reiter, Fabian Bahlke et al.
EP Europace
Cardiovascular Disease and Adiposity
article

Photon-counting ct evaluation of regional wall thickness and epicardial fat distribution in the left atrium

Isabel Deisenhofer, Madeleine Tydecks, Theresa Reiter, Fabian Bahlke, Marta Telishevska, Nico Erhard, Sarah Lengauer, Florian Englert, J Syvaeri, Gabriele Hessling, E Koops, Hannah Krafft, Miruna Popa, Alexander Tunsch-Martinez, D Dischel
article en

Abstract

Abstract Background Achieving sufficient ablation lesions can be challenging, and it has long been suspected that wall thickness plays a significant role in this process, along with the potential influence of epicardial fat. Traditional imaging techniques with a high spatial resolution often lack the resolution necessary for accurate assessment of these anatomical features. The advent of Photon-Counting Computed Tomography (CT) enhances imaging capabilities, allowing for precise evaluation of wall thickness and epicardial fat distribution. Purpose The purpose of this study was to characterize wall thickness and epicardial fat of different regions in the LA with a photon-counting CT. Methods High-resolution photon-counting CT was performed pre-interventionally in 50 patients undergoing AF ablation as part of a prospective study. After processing the CT scans with the 3D segmentation software to measure wall thickness and epicardial fat thickness, the left atrium was segmented into six regions (anterior, roof, posterior, inferior, lateral, septal) using the Paraview 5.12.0 visualization program. For each region, the mean, median, and standard deviation of wall thickness and epicardial fat were calculated. Results The mean wall thickness (± standard deviation) and median with interquartile range (Q1–Q3) were observed in each region of the left atrium as follows: anterior: mean 1.79 ± 0.26 mm, median 1.80 [1.56–1.93] mm; roof: mean 1.58 ± 0.31 mm, median 1.55 [1.34–1.78] mm; posterior: mean 1.79 ± 0.32 mm, median 1.78 [1.57–2.08] mm; inferior: mean 1.74 ± 0.36 mm, median 1.69 [1.50–2.03] mm; lateral: mean 1.76 ± 0.36 mm, median 1.75 [1.51–1.97] mm; and septal: mean 1.81 ± 0.27 mm, median 1.77 [1.65–2.04] mm. Epicardial fat thickness showed notable regional variability, with mean (± standard deviation) and median with interquartile range as follows: anterior: mean 2.25 ± 0.88 mm, median 2.12 [1.64–2.84] mm; roof: mean 1.94 ± 1.23 mm, median 3.05 [0.93–2.89] mm; posterior: mean 0.23 ± 0.25 mm, median 0.12 [0.03–0.39] mm; inferior: mean 1.34 ± 0.88 mm, median 1.36 [0.67–1.95] mm; and lateral: mean 2.56 ± 1.17 mm, median 2.42 [1.82–3.15] mm. Conclusion This study provides a comprehensive evaluation of regional wall thickness and epicardial fat distribution in the left atrium using high-resolution photon-counting CT. Wall thickness is homogeneous within individual patients but shows significant heterogeneity between patients, highlighting the need for high-resolution imaging for accurate assessment. In contrast, epicardial fat distribution is highly heterogeneous within individual patients, particularly in the posterior region. These findings emphasize the importance of considering both regional variations in wall thickness and fat distribution when planning ablation strategies for atrial fibrillation, potentially improving procedural outcomes and patient management.segmented regions,wall thickness,epi fat mean wall thickness, epi fat per region

EP EuropaceVol. 27(Supplement_1)
Deutsches Herzzentrum München (DE)
Deutsche Herzstiftung
Openalex Percentile: Top 79%
Cardiovascular Disease and Adiposity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.