The new screw-in fixation single chamber leadless pacemaker: a change of paradigm in the light of the initial real-world experience

Abstract Background Leadless pacemaker (LPM) has become a well-established alternative to transvenous pacemaker in the management of bradyarrhythmia offering significant improvements with regards to pacing modes. Since June 2023, the new screw-in fixation LPM (Aveir-VR, Abbott Inc.) has been available on the European market. Additionally to its hardware design, this device differs from the more widespread tine-based LPM (Micra, Medtronic Inc.) also for its recent option of dual chamber upgrading with DDD/R pacing mode. At present, reported experiences with the Aveir-VR are limited due to its recent market introduction. Purpose We present the initial short-term real-world results of the Aveir-VR LPM implantation, in comparison with the Micra-VR and Micra-AV LPM during the same time period. Methods Between June 2023 and September 2024, consecutive patients implanted with an Aveir-VR, a Micra-VR, or a Micra-AV LPM in three Italian hospitals were retrospective included in the analysis. Indication for an LPM, implant features, safety, and electrical performance were investigated at time of implant and during short-term follow-up (FU). Results In a total population of 174 LPM patients, 44 patients (25%) received a Micra-VR, 74 (42%) a Micra-AV, and 56 (33%) an Aveir-VR. Baseline characteristics were similar across the three groups (Table 1). Longer procedure and fluoroscopy times were associated to Aveir-VR implantation as compared with Micra-VR and Micra-AV (Table 2). Among patients not requiring atrioventricular (AV) synchrony/atrial pacing (e.g. atrial fibrillation with slow ventricular rate), the implantation rate of the Aveir-VR was significantly lower in comparison to the Micra-VR (19.6% vs. 79.5%, p<0.001). The Aveir-VR was preferred over the Micra-AV in patients with sinus node disease (28.6% vs 10.8%, p=0.027), while implantation rates of the two devices were similar in patients implanted for paroxysmal AV block (Aveir-VR 26.8% vs. Micra-AV 41.9%, p=0.177) (Figure). Micra device was mostly preferred due to concerns about higher infection risk and vascular access, while physician preference was the predominant reason leading to Aveir-VR implantation (Figure). The rate of adverse events and patients with high pacing thresholds were comparable between groups at implantation and after 52 [36-77] days FU. Conclusions In the real-world setting, initial experience with the Aveir-VR showed a significant implantation rate (42%) among LPM patients. Although VVI pacing mode was the only option available until June 2024, the Aveir-VR was perceived as an attractive choice particularly in the light of the anticipated dual chamber upgrade, thus driving a considerable implantation rate even at the cost of a temporary inappropriate VVI stimulation. Figure

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.572
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The new screw-in fixation single chamber leadless pacemaker: a change of paradigm in the light of the initial real-world experience

Elisa Calvi, Matteo Moretti, Gianmarco Arabia, Giovanni B. Forleo et al.
EP Europace
Cardiac pacing and defibrillation studies
article

The new screw-in fixation single chamber leadless pacemaker: a change of paradigm in the light of the initial real-world experience

Elisa Calvi, Matteo Moretti, Gianmarco Arabia, Giovanni B. Forleo, Marialessia Denora, Paolo Vinciguerra, Roberto Arosio, Giuseppe Fonte, Antonio Curnis, Ambra Nicolai, Manuel Cerini, Gianfranco Mitacchione, Luca Bontempi, P Fornaro, P Ponchia
article en

Abstract

Abstract Background Leadless pacemaker (LPM) has become a well-established alternative to transvenous pacemaker in the management of bradyarrhythmia offering significant improvements with regards to pacing modes. Since June 2023, the new screw-in fixation LPM (Aveir-VR, Abbott Inc.) has been available on the European market. Additionally to its hardware design, this device differs from the more widespread tine-based LPM (Micra, Medtronic Inc.) also for its recent option of dual chamber upgrading with DDD/R pacing mode. At present, reported experiences with the Aveir-VR are limited due to its recent market introduction. Purpose We present the initial short-term real-world results of the Aveir-VR LPM implantation, in comparison with the Micra-VR and Micra-AV LPM during the same time period. Methods Between June 2023 and September 2024, consecutive patients implanted with an Aveir-VR, a Micra-VR, or a Micra-AV LPM in three Italian hospitals were retrospective included in the analysis. Indication for an LPM, implant features, safety, and electrical performance were investigated at time of implant and during short-term follow-up (FU). Results In a total population of 174 LPM patients, 44 patients (25%) received a Micra-VR, 74 (42%) a Micra-AV, and 56 (33%) an Aveir-VR. Baseline characteristics were similar across the three groups (Table 1). Longer procedure and fluoroscopy times were associated to Aveir-VR implantation as compared with Micra-VR and Micra-AV (Table 2). Among patients not requiring atrioventricular (AV) synchrony/atrial pacing (e.g. atrial fibrillation with slow ventricular rate), the implantation rate of the Aveir-VR was significantly lower in comparison to the Micra-VR (19.6% vs. 79.5%, p<0.001). The Aveir-VR was preferred over the Micra-AV in patients with sinus node disease (28.6% vs 10.8%, p=0.027), while implantation rates of the two devices were similar in patients implanted for paroxysmal AV block (Aveir-VR 26.8% vs. Micra-AV 41.9%, p=0.177) (Figure). Micra device was mostly preferred due to concerns about higher infection risk and vascular access, while physician preference was the predominant reason leading to Aveir-VR implantation (Figure). The rate of adverse events and patients with high pacing thresholds were comparable between groups at implantation and after 52 [36-77] days FU. Conclusions In the real-world setting, initial experience with the Aveir-VR showed a significant implantation rate (42%) among LPM patients. Although VVI pacing mode was the only option available until June 2024, the Aveir-VR was perceived as an attractive choice particularly in the light of the anticipated dual chamber upgrade, thus driving a considerable implantation rate even at the cost of a temporary inappropriate VVI stimulation. Figure

EP EuropaceVol. 27(Supplement_1)
Brescia University (US), Luigi Sacco Hospital (IT), Azienda Ospedaliera Bolognini Seriate (IT)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.