Impact of higher esophageal temperature thresholds on freeze termination rates: comparison of two cryoballoon systems in AF ablation

Abstract Methods A prospective observational single-center study with a retrospective analysis of procedural data was conducted to assess the effects of ET thresholds on freeze termination rates. Data from the POLARx™ system (Group A) and the Arctic Front AdvancePro™ system (Group B) were compared. Procedures were guided by pulmonary vein angiography and intracardiac echocardiography, with cryo-dosing based on time-to-isolation (TTI). A standard freeze duration of 180 seconds was employed, with additional applications as necessary. Continuous monitoring of ET was performed using an S-CATH Esophageal Temperature Probe, and freeze applications were terminated when the ET dropped below 15°C. A hypothetical termination rate was calculated for the proposed cut-off of 20°C. Results From October 2018 to October 2024, a total of 1,757 patients (50.7% paroxysmal AF) were enrolled, with a mean age of 66.2 years. The cohort included 1,058 males (60.2%) and 699 females (39.8%). Three hundred thirty-patients (18.8%) were treated in group A, and 1,426 patients (81.2%) were assigned to group B. In group B, persistent AF was documented more frequently (55.0% vs. 22.7%, p<0.001). Significant procedural differences were noted, with Group A having lower median dose area products than Group B (701 cGy×cm² vs. 916 cGy×cm², p<0.001). Acute PVI was achieved in 7,116 veins (99.8%), with a median time to isolation of 37 seconds and a single-shot success rate of 91.0%. TTI was recorded in 73.1% of cases, with Group A showing a higher single-shot success rate (93.9% vs. 91.1%, p<0.001). Minimal esophageal temperatures were similar (34.4°C vs. 35.2°C, p=0.125), but minimal balloon temperatures were lower in Group A (-56.0°C vs. -49.0°C, p<0.001). Freeze termination rates due to low ET (<15°C) were equal in both groups (5.5% vs. 5.6%, p=1.0). Hypothetically increased thresholds (<20°C) for freeze termination showed no significant difference (10.8% vs. 10.2%, p=0.51). Freeze termination due to low ET occurred most frequently in the left inferior pulmonary vein (LIPV) (13.3%) and right inferior pulmonary vein (RIPV) (6.9%). Increased ET (<20°C) would significantly raise freeze terminations in the LIPV (23.6%) and RIPV (11.8%). Conclusion Raising the ET threshold from 15°C to 20°C for freeze application termination in CBA significantly increases termination rates, especially in the LIPV and RIPV. No significant differences were found between the two available CBA systems regarding freeze terminations or procedural success. While a higher threshold may enhance safety by reducing the risk of AEF, it may also lead to more frequent freeze interruptions.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.419
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of higher esophageal temperature thresholds on freeze termination rates: comparison of two cryoballoon systems in AF ablation

Michael Wankerl, Ellen Hoffmann, J Pongratz, Uwe Dorwarth et al.
4 links
EP Europace
Aerosol Filtration and Electrostatic Precipitation
article

Impact of higher esophageal temperature thresholds on freeze termination rates: comparison of two cryoballoon systems in AF ablation

Michael Wankerl, Ellen Hoffmann, J Pongratz, Uwe Dorwarth, Florian Straube, L Riess, P Renz, J Holz
article en

Abstract

Abstract Methods A prospective observational single-center study with a retrospective analysis of procedural data was conducted to assess the effects of ET thresholds on freeze termination rates. Data from the POLARx™ system (Group A) and the Arctic Front AdvancePro™ system (Group B) were compared. Procedures were guided by pulmonary vein angiography and intracardiac echocardiography, with cryo-dosing based on time-to-isolation (TTI). A standard freeze duration of 180 seconds was employed, with additional applications as necessary. Continuous monitoring of ET was performed using an S-CATH Esophageal Temperature Probe, and freeze applications were terminated when the ET dropped below 15°C. A hypothetical termination rate was calculated for the proposed cut-off of 20°C. Results From October 2018 to October 2024, a total of 1,757 patients (50.7% paroxysmal AF) were enrolled, with a mean age of 66.2 years. The cohort included 1,058 males (60.2%) and 699 females (39.8%). Three hundred thirty-patients (18.8%) were treated in group A, and 1,426 patients (81.2%) were assigned to group B. In group B, persistent AF was documented more frequently (55.0% vs. 22.7%, p<0.001). Significant procedural differences were noted, with Group A having lower median dose area products than Group B (701 cGy×cm² vs. 916 cGy×cm², p<0.001). Acute PVI was achieved in 7,116 veins (99.8%), with a median time to isolation of 37 seconds and a single-shot success rate of 91.0%. TTI was recorded in 73.1% of cases, with Group A showing a higher single-shot success rate (93.9% vs. 91.1%, p<0.001). Minimal esophageal temperatures were similar (34.4°C vs. 35.2°C, p=0.125), but minimal balloon temperatures were lower in Group A (-56.0°C vs. -49.0°C, p<0.001). Freeze termination rates due to low ET (<15°C) were equal in both groups (5.5% vs. 5.6%, p=1.0). Hypothetically increased thresholds (<20°C) for freeze termination showed no significant difference (10.8% vs. 10.2%, p=0.51). Freeze termination due to low ET occurred most frequently in the left inferior pulmonary vein (LIPV) (13.3%) and right inferior pulmonary vein (RIPV) (6.9%). Increased ET (<20°C) would significantly raise freeze terminations in the LIPV (23.6%) and RIPV (11.8%). Conclusion Raising the ET threshold from 15°C to 20°C for freeze application termination in CBA significantly increases termination rates, especially in the LIPV and RIPV. No significant differences were found between the two available CBA systems regarding freeze terminations or procedural success. While a higher threshold may enhance safety by reducing the risk of AEF, it may also lead to more frequent freeze interruptions.

EP EuropaceVol. 27(Supplement_1)
München Klinik Bogenhausen (DE), München Klinik (DE)
Openalex Percentile: Top 91%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.