Micra vs Aveir leadless peacemakers: which is the best option? Experience implantation and follow-up in a medium-volume centre in Spain

Abstract Background As the population ages, the number of pacemaker implantations is increasing. To avoid complications associated with traditional pacemakers, leadless pacemakers have been developed as a safe and effective alternative pacing therapy. In 2023 in Europe was introduced a novel leadless stimulation system Aveir (Abbott) as an alternative to the Micra (Medtronic) system, which has been in use since 2016. Purpose To compare safety, effectiveness, and electrical parameters at implantation and during follow-up between Micra and Aveir at real-word performance. Methods Single-centre, observational, prospective, analytical study in Spain. We consecutively enrolled all patients available receiving Micra and Aveir between March 2022 and October 2024. The clinical variables and characteristics related to pre- or implantation procedure were collected, as well as safety (acute or subacute/chronic complications), and post-implantation electrical parameters at the time of procedure and in two posterior visits: one-month post-implantation, and at three-month follow-up. Statistical analysis was conducted using the SPSS 28.0 version software. Results 53 patients (pts) undergone leadless pacemaker implantation, 34 Micra-Medtronic AV and VR and 19 patients who had received the Aveir-Abbott VR. The majority were of advanced age (mean 73.79) and the electrocardiographic indication was slow/blocked atrial fibrillation (84,2%). Baseline characteristics and clinical variables related to procedure were comparable and are illustrated in table 1. Implantation was achieved in 100% (19) of patients in the Aveir group with one Micra system failure (NS). A single device release was lower in the Aveir group (68.4% vs. 79.4%; p = 0.38) and the number of releases needed was similar (1.4 vs. 1.38; p = 0.24). Furthermore, procedure times (in minutes) (51.96 vs. 49.13; p = 0.29) and escopia (13.99 vs. 10; p = 0.3) were analogous. Two patients (10.5%) experienced complications: a device dislodge and AV block during implantation in Aveir group. The electrical parameters at implantation, first and third month were equivalent. Following implantation, the R wave was lower in the Aveir group (7,647[±3,32] vs 11,36 [±4,77] p=0,04) and a statistically significant higher threshold was maintained during the first visit (0,6 [±0,16 vs 0,46 [±0,23] p=0,05) but not in three-month follow-up, as illustrated in Figure 1. It was remarkable that within 53.5% of pacing, the estimated longevity at 3 months was 18,25 years in the Aveir group. Conclusion The Aveir device is an effective and safe alternative with electrical parameters comparable to Micra in terms of monitoring. Larger sample studies are needed to confirm our findings.Table 1.Baseline characteristics Figure 1.Electrical parameters

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.549
Primary Topic
European and Russian Geopolitical Military Strategies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micra vs Aveir leadless peacemakers: which is the best option? Experience implantation and follow-up in a medium-volume centre in Spain

Carlos Gil-Guillén, P M Ruiz-Hernandez, Federico Segura-Villalobos, Adrien Gandolfo et al.
EP Europace
European and Russian Geopolitical Military Strategies
article

Micra vs Aveir leadless peacemakers: which is the best option? Experience implantation and follow-up in a medium-volume centre in Spain

Carlos Gil-Guillén, P M Ruiz-Hernandez, Federico Segura-Villalobos, Adrien Gandolfo, Alfredo Santana, Saúl Martín-Rodríguez, Natalia Marrero‐Negrín, F M Jimenez-Cabrera, E Mateu-Gisbert, J D Umana-Monzon, R Zerpa
article en

Abstract

Abstract Background As the population ages, the number of pacemaker implantations is increasing. To avoid complications associated with traditional pacemakers, leadless pacemakers have been developed as a safe and effective alternative pacing therapy. In 2023 in Europe was introduced a novel leadless stimulation system Aveir (Abbott) as an alternative to the Micra (Medtronic) system, which has been in use since 2016. Purpose To compare safety, effectiveness, and electrical parameters at implantation and during follow-up between Micra and Aveir at real-word performance. Methods Single-centre, observational, prospective, analytical study in Spain. We consecutively enrolled all patients available receiving Micra and Aveir between March 2022 and October 2024. The clinical variables and characteristics related to pre- or implantation procedure were collected, as well as safety (acute or subacute/chronic complications), and post-implantation electrical parameters at the time of procedure and in two posterior visits: one-month post-implantation, and at three-month follow-up. Statistical analysis was conducted using the SPSS 28.0 version software. Results 53 patients (pts) undergone leadless pacemaker implantation, 34 Micra-Medtronic AV and VR and 19 patients who had received the Aveir-Abbott VR. The majority were of advanced age (mean 73.79) and the electrocardiographic indication was slow/blocked atrial fibrillation (84,2%). Baseline characteristics and clinical variables related to procedure were comparable and are illustrated in table 1. Implantation was achieved in 100% (19) of patients in the Aveir group with one Micra system failure (NS). A single device release was lower in the Aveir group (68.4% vs. 79.4%; p = 0.38) and the number of releases needed was similar (1.4 vs. 1.38; p = 0.24). Furthermore, procedure times (in minutes) (51.96 vs. 49.13; p = 0.29) and escopia (13.99 vs. 10; p = 0.3) were analogous. Two patients (10.5%) experienced complications: a device dislodge and AV block during implantation in Aveir group. The electrical parameters at implantation, first and third month were equivalent. Following implantation, the R wave was lower in the Aveir group (7,647[±3,32] vs 11,36 [±4,77] p=0,04) and a statistically significant higher threshold was maintained during the first visit (0,6 [±0,16 vs 0,46 [±0,23] p=0,05) but not in three-month follow-up, as illustrated in Figure 1. It was remarkable that within 53.5% of pacing, the estimated longevity at 3 months was 18,25 years in the Aveir group. Conclusion The Aveir device is an effective and safe alternative with electrical parameters comparable to Micra in terms of monitoring. Larger sample studies are needed to confirm our findings.Table 1.Baseline characteristics Figure 1.Electrical parameters

EP EuropaceVol. 27(Supplement_1)
Hospital Universitario Insular de Gran Canaria (ES)
Openalex Percentile: Top 87%
European and Russian Geopolitical Military Strategies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.