The acute changes in parameters of cardiac implantable electronic devices in patients undergoing radiation therapy

Abstract Background The number of patients with cardiac implantable electronic devices (CIEDs) requiring effective cancer treatment, including radiotherapy (RT), is increasing year by year. A potentially harmful effect of RT on CIEDs depending on the type and physical parameters of radiation, location of the treated lesion, indications for electrotherapy, and the type of devices have been described in literature. Purpose The aim of this study was to present short-time effect of radiotherapy on cardiac implantable electronic devices parameters. Methods We analyzed real-world data of patients with CIEDs underwent RT in a large, tertiary cardio-oncological centre between November 2016 and December 2023. Clinical, RT (localization of cancer, number of fractions, time of radiotherapy, cumulative dose, and dose per fraction) and CIED parameters from interrogation during first cardiologist consultation and after the last RT session (including type of CIED, pacing settings, and battery longevity, and device malfunction if any) were collected. Results The study included 365 patients with CIEDs who had palliative or radical RT. Pacemakers were implanted in 281 patients, implantable cardioverter-defibrillators in 52, and devices with cardiac resynchronization therapy in 32, including two patients with left bundle branch pacing–optimized cardiac resynchronization therapy. Patient received cumulative dose up to 112 Gy per patient for the whole RT treatment (median [interquartile range], 36.25 [20–65] in about 10 fractions (10 [5-30]). In 55,8% of cases the tumor treated with radiotherapy were located under the diaphragm. All patients presented at cardiology consultations were admitted to radiotherapy. RT was administered without the need of device relocation. No device malfunctions or significant changes in battery longevity and lead parameters during radiotherapy were observed, except for the change in impedance at the LV electrode (p=0.04). However, these data were from a small group of patients (n=28) and were numerically not clinically significant. In individual cases, it was necessary to temporarily postpone radiotherapy due to the need to reposition the RV electrode, replace the device battery, plasty the implanted device pocket or extend invasive cardiological diagnostics. Conclusions Our analysis found no clinically significant changes in lead and battery parameters, indicating that radiotherapy for patients with CIEDs can be considered safe where appropriate precautions were implemented.Clinical and radiotherapy characteristic CIED parameters before and after RT

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.773
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The acute changes in parameters of cardiac implantable electronic devices in patients undergoing radiation therapy

Aleksandra Błachut, Adam Wojtaszczyk, Sławomir Blamek, Matthew E. Witek et al.
EP Europace
Cardiac pacing and defibrillation studies
article

The acute changes in parameters of cardiac implantable electronic devices in patients undergoing radiation therapy

Aleksandra Błachut, Adam Wojtaszczyk, Sławomir Blamek, Matthew E. Witek, Joanna Machowicz, Elżebieta Wojtynek, Jerzy Wydmański, Mariusz Gąsior, Jacek Niedziela, Tomasz Rutkowski, Maciej Dyrbuś, Mateusz Tajstra, A. Kurek, Jarosław Gorol
article en

Abstract

Abstract Background The number of patients with cardiac implantable electronic devices (CIEDs) requiring effective cancer treatment, including radiotherapy (RT), is increasing year by year. A potentially harmful effect of RT on CIEDs depending on the type and physical parameters of radiation, location of the treated lesion, indications for electrotherapy, and the type of devices have been described in literature. Purpose The aim of this study was to present short-time effect of radiotherapy on cardiac implantable electronic devices parameters. Methods We analyzed real-world data of patients with CIEDs underwent RT in a large, tertiary cardio-oncological centre between November 2016 and December 2023. Clinical, RT (localization of cancer, number of fractions, time of radiotherapy, cumulative dose, and dose per fraction) and CIED parameters from interrogation during first cardiologist consultation and after the last RT session (including type of CIED, pacing settings, and battery longevity, and device malfunction if any) were collected. Results The study included 365 patients with CIEDs who had palliative or radical RT. Pacemakers were implanted in 281 patients, implantable cardioverter-defibrillators in 52, and devices with cardiac resynchronization therapy in 32, including two patients with left bundle branch pacing–optimized cardiac resynchronization therapy. Patient received cumulative dose up to 112 Gy per patient for the whole RT treatment (median [interquartile range], 36.25 [20–65] in about 10 fractions (10 [5-30]). In 55,8% of cases the tumor treated with radiotherapy were located under the diaphragm. All patients presented at cardiology consultations were admitted to radiotherapy. RT was administered without the need of device relocation. No device malfunctions or significant changes in battery longevity and lead parameters during radiotherapy were observed, except for the change in impedance at the LV electrode (p=0.04). However, these data were from a small group of patients (n=28) and were numerically not clinically significant. In individual cases, it was necessary to temporarily postpone radiotherapy due to the need to reposition the RV electrode, replace the device battery, plasty the implanted device pocket or extend invasive cardiological diagnostics. Conclusions Our analysis found no clinically significant changes in lead and battery parameters, indicating that radiotherapy for patients with CIEDs can be considered safe where appropriate precautions were implemented.Clinical and radiotherapy characteristic CIED parameters before and after RT

EP EuropaceVol. 27(Supplement_1)
Wojewódzki Szpital Specjalistyczny nr 4 w Bytomiu (PL), Medical University of Lodz (PL), Silesian Center for Heart Disease (PL)
Openalex Percentile: Top 79%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.