Advancements in ablation technology lead to improved durability and outcome of pulmonary vein isolation using radiofrequency energy

Abstract Introduction During the last decade, pulmonary vein isolation (PVI) has become the most effective treatment for patients with atrial fibrillation. However, success rates after the first interventions were less favourable, creating durable PV isolation proved to be a technological challenge, consequently, repeated (redo) interventions were often performed. Purpose Our objective was to examine how the proportions of redo PVIs and the PV reconnection rate have evolved in the practice of our institution in the light of the techological evolution of the past decade. Methods We retrospectively analyzed the demographic and procedural data of patients undergoing first PVI, using point-by-point radiofrequency (RF) technology between 2013 and 2024 in terms of technology used at index PVI, outcome during follow-up and PV reconnections at redo procedures. The RF technology was categorized using a scoring system, where irrigated-RF catheter technology was the basis (0 point), and each additional technological improvement used (contact force sensing, steerable sheath, Ablation Index, high power-short duration RF) increased the score by 1, up to a maximum of 4 points. Results During the study period, 1580 patients underwent point-by-point RF PVI (60% male, age 62±10 years) and subsequently, 367 patients (23%) had redo interventions during the follow-up (25±26 months). The rate of first redo PVIs after index PVIs in ten years showed a significantly declining trend (53% in 2013, 6% in 2023, p<0.001). There was an inverse correlation between the technological points of the index procedures and the recurrence rate during follow-up (66%, 64%, 51%, 34%, 33%, in case of points 0 through 4, respectively, p<0.001). Lower technological score and persistent AF proved to be independent predictors of recurrence (p<0.001 and p=0.01, respectively). During the redo procedures, an inverse correlation was observed between the technology score of the index PVI and the rate of PV reconnection (88%, 99%, 74%, 59%, 46%, in case of points 0 through 4, respectively, p<0.001). Similarly, the number of reconnected PVs decreased with increasing score (a mean of 1.90, 2.0, 1.46, 1.23, 0.85 PVs, in case of points 0 through 4, respectively, p<0.001). In accordance with technological evolution, a significant increase was observed in the frequency of zero reconnection (0 points: 12%, 1 point: 11%, 2 points: 26%, 3 points: 41%, 4 points: 54%, p<0.001, Figure). Conclusion Paralell with the evolution of applied RF technology, the rate of redo PVI interventions, the phenomenon and extent of PV reconnection during redos have shown a significantly declining trend. These observations may reevaluate long-term management strategies for arrhythmia recurrences after PVI.Figure

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.450
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancements in ablation technology lead to improved durability and outcome of pulmonary vein isolation using radiofrequency energy

László Sághy, Tamás Szili‐Törok, Róbert Pap, M Miklos et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Advancements in ablation technology lead to improved durability and outcome of pulmonary vein isolation using radiofrequency energy

László Sághy, Tamás Szili‐Törok, Róbert Pap, M Miklos, A Benak, Máté Vámos, Gábor Bencsik, N Pataky
article en

Abstract

Abstract Introduction During the last decade, pulmonary vein isolation (PVI) has become the most effective treatment for patients with atrial fibrillation. However, success rates after the first interventions were less favourable, creating durable PV isolation proved to be a technological challenge, consequently, repeated (redo) interventions were often performed. Purpose Our objective was to examine how the proportions of redo PVIs and the PV reconnection rate have evolved in the practice of our institution in the light of the techological evolution of the past decade. Methods We retrospectively analyzed the demographic and procedural data of patients undergoing first PVI, using point-by-point radiofrequency (RF) technology between 2013 and 2024 in terms of technology used at index PVI, outcome during follow-up and PV reconnections at redo procedures. The RF technology was categorized using a scoring system, where irrigated-RF catheter technology was the basis (0 point), and each additional technological improvement used (contact force sensing, steerable sheath, Ablation Index, high power-short duration RF) increased the score by 1, up to a maximum of 4 points. Results During the study period, 1580 patients underwent point-by-point RF PVI (60% male, age 62±10 years) and subsequently, 367 patients (23%) had redo interventions during the follow-up (25±26 months). The rate of first redo PVIs after index PVIs in ten years showed a significantly declining trend (53% in 2013, 6% in 2023, p<0.001). There was an inverse correlation between the technological points of the index procedures and the recurrence rate during follow-up (66%, 64%, 51%, 34%, 33%, in case of points 0 through 4, respectively, p<0.001). Lower technological score and persistent AF proved to be independent predictors of recurrence (p<0.001 and p=0.01, respectively). During the redo procedures, an inverse correlation was observed between the technology score of the index PVI and the rate of PV reconnection (88%, 99%, 74%, 59%, 46%, in case of points 0 through 4, respectively, p<0.001). Similarly, the number of reconnected PVs decreased with increasing score (a mean of 1.90, 2.0, 1.46, 1.23, 0.85 PVs, in case of points 0 through 4, respectively, p<0.001). In accordance with technological evolution, a significant increase was observed in the frequency of zero reconnection (0 points: 12%, 1 point: 11%, 2 points: 26%, 3 points: 41%, 4 points: 54%, p<0.001, Figure). Conclusion Paralell with the evolution of applied RF technology, the rate of redo PVI interventions, the phenomenon and extent of PV reconnection during redos have shown a significantly declining trend. These observations may reevaluate long-term management strategies for arrhythmia recurrences after PVI.Figure

EP EuropaceVol. 27(Supplement_1)
University of Szeged (HU)
Openalex Percentile: Top 79%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.