Artificial intelligence assisted QT interval measurement in 12-lead-ECGs

Abstract Introduction In electrocardiograms (ECGs), the QT interval reflects the repolarization status of the heart. Currently, the QT interval automatically measured in 12-lead ECG is inaccurately derived as the median value. This approach fails to provide information on heterogeneous QT prolongation crucial for predicting arrhythmias, as it does not accurately represent the values of QT intervals in each lead. Aim Measurement of the true QT interval is challenging, even for EP cardiologists. To address this challenge, we present a model that eliminates baseline wander and noise occurring during ECG and incorporates Convolutional Neural Networks (CNN) and Bidirectional Long Short-Term Memory (Bi-LSTM) to estimate QT intervals. Methods The dataset used in this study were the QT Database, (two leads ECG data for 15 minutes from 63 patients) and Lobachevsky University database (12 leads ECG data for 10 seconds from 200 patients) with the annotation of P, QRS, and T waves. We structured these dataset into a ratio of 8:1:1 for train: Validation: Test. AI model combining CNN and Bi-LSTM was proposed to estimate the QT interval of ECG. Result For the evaluation of deep learning, We also tested a similar recurrent neural network, GRU, with the same unit configuration. The results indicated that the method with two Bi-LSTM layers outperformed others in both Accuracy and F1-Score. For QT interval estimation in the QT database, Accuracy was 0.940 and F1-score was 0.938. Those of LU database were 0.927 and 0.921. Conclusion By incorporating CNN and Bi-LSTM, we conducted sufficiently accurate estimation of QT interval, leveraging temporal features of ECG. In our future research endeavours, we plan to deploy this model for predicting repolarization arrhythmias, specifically targeting conditions like long QT syndrome, drug-induced QT prolongation, and torsade pointes in ischemic cardiomyopathy.Visualization of QT estimation with AI Model performance for QT estimation

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.838
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence assisted QT interval measurement in 12-lead-ECGs

S B Park, Y R Kim, Hong Yang, Seung Jin Lee
EP Europace
ECG Monitoring and Analysis
article

Artificial intelligence assisted QT interval measurement in 12-lead-ECGs

S B Park, Y R Kim, Hong Yang, Seung Jin Lee
article en

Abstract

Abstract Introduction In electrocardiograms (ECGs), the QT interval reflects the repolarization status of the heart. Currently, the QT interval automatically measured in 12-lead ECG is inaccurately derived as the median value. This approach fails to provide information on heterogeneous QT prolongation crucial for predicting arrhythmias, as it does not accurately represent the values of QT intervals in each lead. Aim Measurement of the true QT interval is challenging, even for EP cardiologists. To address this challenge, we present a model that eliminates baseline wander and noise occurring during ECG and incorporates Convolutional Neural Networks (CNN) and Bidirectional Long Short-Term Memory (Bi-LSTM) to estimate QT intervals. Methods The dataset used in this study were the QT Database, (two leads ECG data for 15 minutes from 63 patients) and Lobachevsky University database (12 leads ECG data for 10 seconds from 200 patients) with the annotation of P, QRS, and T waves. We structured these dataset into a ratio of 8:1:1 for train: Validation: Test. AI model combining CNN and Bi-LSTM was proposed to estimate the QT interval of ECG. Result For the evaluation of deep learning, We also tested a similar recurrent neural network, GRU, with the same unit configuration. The results indicated that the method with two Bi-LSTM layers outperformed others in both Accuracy and F1-Score. For QT interval estimation in the QT database, Accuracy was 0.940 and F1-score was 0.938. Those of LU database were 0.927 and 0.921. Conclusion By incorporating CNN and Bi-LSTM, we conducted sufficiently accurate estimation of QT interval, leveraging temporal features of ECG. In our future research endeavours, we plan to deploy this model for predicting repolarization arrhythmias, specifically targeting conditions like long QT syndrome, drug-induced QT prolongation, and torsade pointes in ischemic cardiomyopathy.Visualization of QT estimation with AI Model performance for QT estimation

EP EuropaceVol. 27(Supplement_1)
Chonnam National University (KR), Chonnam National University Hospital (KR), Convergence (US)
Openalex Percentile: Top 79%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.