Multicenter comparative study of pulsed field ablation vs. radiofrequency balloon ablation for paroxysmal atrial fibrillation: a propensity score matched analysis

Abstract Introduction Pulsed Field Ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We performed a multicentre comparative study on Pulmonary Vein Isolation (PVI) with PFA or Radiofrequency Balloon (RFB) ablation for Paroxysmal Atrial Fibrillation (PAF). Methods This prospective multicenter study included all consecutive patients with symptomatic drug-resistant paroxysmal AF undergoing PVI with PFA or RFB between July 2022 and May 2024. The primary efficacy endpoint included PVI rate with the single-shot device only and arrhythmia-free survival at 1-year follow-up. The primary safety endpoint was a composite of device-related major adverse events within 7 days. A propensity score matching technique was adopted to attenuate the imbalance of covariates among the two groups (PFA:RFB ratio = 1:1). Results Among 764 PAF patients undergoing first time PVI with either PFA (n = 316) and RFB (n = 448), propensity score matching yielded 173 PFA and 173 RFB patients. The PVI rate using the single-shot device only was higher in the PFA group than in the RFB group on PV basis (100% vs 98.8%; p=0.005) and patient basis (100% vs 96.5%; p=0.013). At 1-year follow up no differences were reported for any atrial tachyarrhythmia (86.9% vs 87.8%; p= 0.87) and atrial fibrillation recurrence (88.8% vs 89.2%; p= 0.73) between PFA and RFB. No difference was found for major complications (0% vs 1.2%; p=0.16) and overall complications (1.7% vs 2.9%; p=0.47) between PFA and RFB. No differences were found for left atrium dwelling time (29 vs 25 min; p=0.42) and Fluoroscopy time (15 vs 14.5 min; p=0.54) between PFA and RFB. Conclusions While PFA may offer procedural advantages, both techniques are comparably effective in maintaining sinus rhythm after one year of follow-up with good safety profiles.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.165
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multicenter comparative study of pulsed field ablation vs. radiofrequency balloon ablation for paroxysmal atrial fibrillation: a propensity score matched analysis

Carlo de Asmundis, A Almorad, René Worck, Carmelo La Greca et al.
EP Europace
Atrial Fibrillation Management and Outcomes
article

Multicenter comparative study of pulsed field ablation vs. radiofrequency balloon ablation for paroxysmal atrial fibrillation: a propensity score matched analysis

Carlo de Asmundis, A Almorad, René Worck, Carmelo La Greca, Charles Audiat, Giampaolo Vetta, Roberto Scacciavillani, Gian‐Battista Chierchia, D Della Rocca, Joseph Antoine Kheir, Alvise Del Monte, G Stabile, Sara Poggi, J Vigen
article en

Abstract

Abstract Introduction Pulsed Field Ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We performed a multicentre comparative study on Pulmonary Vein Isolation (PVI) with PFA or Radiofrequency Balloon (RFB) ablation for Paroxysmal Atrial Fibrillation (PAF). Methods This prospective multicenter study included all consecutive patients with symptomatic drug-resistant paroxysmal AF undergoing PVI with PFA or RFB between July 2022 and May 2024. The primary efficacy endpoint included PVI rate with the single-shot device only and arrhythmia-free survival at 1-year follow-up. The primary safety endpoint was a composite of device-related major adverse events within 7 days. A propensity score matching technique was adopted to attenuate the imbalance of covariates among the two groups (PFA:RFB ratio = 1:1). Results Among 764 PAF patients undergoing first time PVI with either PFA (n = 316) and RFB (n = 448), propensity score matching yielded 173 PFA and 173 RFB patients. The PVI rate using the single-shot device only was higher in the PFA group than in the RFB group on PV basis (100% vs 98.8%; p=0.005) and patient basis (100% vs 96.5%; p=0.013). At 1-year follow up no differences were reported for any atrial tachyarrhythmia (86.9% vs 87.8%; p= 0.87) and atrial fibrillation recurrence (88.8% vs 89.2%; p= 0.73) between PFA and RFB. No difference was found for major complications (0% vs 1.2%; p=0.16) and overall complications (1.7% vs 2.9%; p=0.47) between PFA and RFB. No differences were found for left atrium dwelling time (29 vs 25 min; p=0.42) and Fluoroscopy time (15 vs 14.5 min; p=0.54) between PFA and RFB. Conclusions While PFA may offer procedural advantages, both techniques are comparably effective in maintaining sinus rhythm after one year of follow-up with good safety profiles.

EP EuropaceVol. 27(Supplement_1)
Gentofte Hospital (DK), Jessa Hospital (BE), Clinica Mediterranea (IT), Hartcentrum Hasselt (BE), Fondazione Poliambulanza Istituto Ospedaliero (IT), Université de Strasbourg (FR)
Openalex Percentile: Top 80%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.