Single center experience using a contact force sensing very high power short duration radiofrequency catheter for persistent atrial fibrillation guided with an artificial intelligence based software

Abstract Background/Introduction Recently, the TAILORED-AF randomized clinical trial (NCT04702451) demonstrated superiority of ablating persistent atrial fibrillation (AF) with the targeting of dispersion — identified by an artificial intelligence (AI) software — in addition to PVI vs. a PVI-only strategy. Previously, a contact force–sensing catheter optimized for temperature-controlled, very high-power short-duration (vHPSD) radiofrequency (RF) ablation demonstrated safety and efficacy for AF ablation. Purpose To evaluate the feasibility and procedural efficiency of using a vHPSD catheter for an electrogram-based, artificial intelligence-guided patient-tailored persistent AF ablation approach. Methods We conducted a pilot single-center, non-randomized study of persistent AF patients who underwent a first-time catheter ablation. All patients underwent a TAILORED-AF-like approach consisting of an AI-guided spatiotemporal dispersion ablation in addition to PVI. First, electro-anatomical biatrial mapping was obtained while an AI-guided spatiotemporal dispersion software was employed to highlight dispersion regions in real time. Then, PVI and dispersion ablation were performed with the vHPSD catheter using region-adapted maximal power (posterior wall, 90W and anterior wall, 50W). Procedural characteristics and acute outcomes of a 25-patient cohort (vHPSD cohort) were then compared to a sub-group of patients enrolled in the TAILORED-AF trial who were randomized to dispersion-based ablation with a variety of non-vHPSD ablation catheters (non- vHPSD cohort). Results Of the 25 patients included in the vHPSD cohort (age: 72±8 years; female: 44%; body mass index: 27±5 kg/m²; left ventricular ejection fraction: 50%; cardiomyopathy: 44%; CHADS2-VASc: 2 [1.5-3.0]), 72% had persistent AF and 28% had long-standing persistent AF and no major complication was observed. AF termination occurred in 21/25 patients (84%) in the vHPSD cohort and in 110/170 patients (65%) in the non-vHPSD cohort (p=0.06). Procedure, RF and fluoroscopy times were significantly shorter in the vHPSD vs. in the non-vHPSD TAILORED cohort (127±32 min vs 183±61 min, p<0.001; 23±12 vs 43±17, p<0.001; 4±3 vs 10±10, p<0.001). Conclusion(s) This pilot study demonstrates that the use of a vHPSD catheter is safe and efficient to follow a spatiotemporal dispersion-based ablation procedure. Notably, the use of a vHPSD catheter allows for a significant reduction in TAILORED-AF-like procedure times.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.071
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single center experience using a contact force sensing very high power short duration radiofrequency catheter for persistent atrial fibrillation guided with an artificial intelligence based software

Sabrina Siame, Emmanuelle Martinez, Sabine Lotteau, Hind Regragui et al.
EP Europace
Atrial Fibrillation Management and Outcomes
article

Single center experience using a contact force sensing very high power short duration radiofrequency catheter for persistent atrial fibrillation guided with an artificial intelligence based software

Sabrina Siame, Emmanuelle Martinez, Sabine Lotteau, Hind Regragui, Andrea Ballatore, Julien Seitz, P Milpied, Clément Bars, Jacques Monteau, Edouard Gitenay, Marie‐Sophie Nguyen‐Tu, Jérôme Kalifa, A. Ayari
article en

Abstract

Abstract Background/Introduction Recently, the TAILORED-AF randomized clinical trial (NCT04702451) demonstrated superiority of ablating persistent atrial fibrillation (AF) with the targeting of dispersion — identified by an artificial intelligence (AI) software — in addition to PVI vs. a PVI-only strategy. Previously, a contact force–sensing catheter optimized for temperature-controlled, very high-power short-duration (vHPSD) radiofrequency (RF) ablation demonstrated safety and efficacy for AF ablation. Purpose To evaluate the feasibility and procedural efficiency of using a vHPSD catheter for an electrogram-based, artificial intelligence-guided patient-tailored persistent AF ablation approach. Methods We conducted a pilot single-center, non-randomized study of persistent AF patients who underwent a first-time catheter ablation. All patients underwent a TAILORED-AF-like approach consisting of an AI-guided spatiotemporal dispersion ablation in addition to PVI. First, electro-anatomical biatrial mapping was obtained while an AI-guided spatiotemporal dispersion software was employed to highlight dispersion regions in real time. Then, PVI and dispersion ablation were performed with the vHPSD catheter using region-adapted maximal power (posterior wall, 90W and anterior wall, 50W). Procedural characteristics and acute outcomes of a 25-patient cohort (vHPSD cohort) were then compared to a sub-group of patients enrolled in the TAILORED-AF trial who were randomized to dispersion-based ablation with a variety of non-vHPSD ablation catheters (non- vHPSD cohort). Results Of the 25 patients included in the vHPSD cohort (age: 72±8 years; female: 44%; body mass index: 27±5 kg/m²; left ventricular ejection fraction: 50%; cardiomyopathy: 44%; CHADS2-VASc: 2 [1.5-3.0]), 72% had persistent AF and 28% had long-standing persistent AF and no major complication was observed. AF termination occurred in 21/25 patients (84%) in the vHPSD cohort and in 110/170 patients (65%) in the non-vHPSD cohort (p=0.06). Procedure, RF and fluoroscopy times were significantly shorter in the vHPSD vs. in the non-vHPSD TAILORED cohort (127±32 min vs 183±61 min, p<0.001; 23±12 vs 43±17, p<0.001; 4±3 vs 10±10, p<0.001). Conclusion(s) This pilot study demonstrates that the use of a vHPSD catheter is safe and efficient to follow a spatiotemporal dispersion-based ablation procedure. Notably, the use of a vHPSD catheter allows for a significant reduction in TAILORED-AF-like procedure times.

EP EuropaceVol. 27(Supplement_1)
St. Joseph Hospital (US)
Openalex Percentile: Top 80%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.