Single- versus dual-chamber ICD discriminators for tachyarrhythmia detection: a remote monitoring based, single-center study

Abstract Background Implantable cardioverter defibrillator (ICD) systems are available in both single-chamber (SC) and dual-chamber (DC) configurations, with discrimination functions varying accordingly. Although expert opinion generally suggests that modern SC discriminators equipped with morphology detection algorithms are equally effective to DC systems in tachyarrhythmia discrimination, only limited and contradictory data are available. In most previous reports the choice between SC or DC discrimination was determined by the number of the implanted leads. Purpose We aimed to assess the efficacy of SC vs. DC ICD discriminators in malignant tachyarrhythmias by performing a head-to-head comparison of devices from a single manufacturer, whose ICDs also include single-lead devices with a programmable option of SC or DC discriminators (VDD ICD). Methods Data from ICD recipients followed up with the Home Monitoring system were retrospectively analysed. As primary outcome we compared the risk of inappropriate therapy between patients, whose ICD was programmed to SC (i.e. Stability/Onset/MorphMatch) vs. DC (i.e. SMART) discrimination algorithms. A sensitivity analysis was also conducted including only patients into the SC discrimination group with activated morphology discriminator. Results A total of 211 patients (mean age 64±12, male 75%, primary prophylaxis 33%) were included. All patients had been implanted with an ICD from the same manufacturer (VVI: 62, VDD: 94, DDD: 14, CRT-D: 41), and were remotely followed up. Among these, 71 ICDs were programmed to SC, while 98 were programmed to apply DC discriminators. In the remaining 42 cases, only VF zone was programmed, therefore these patients were excluded from further analysis. Of the SC discriminator group, 35 (49%) patients were programmed to utilize morphology discriminator. There was no significant difference between the SC and DC groups in atrial (6±3 vs. 4±3 mV; p=0.062) or ventricular sensing (15±6 vs. 14±7 mV; p=0.781) at the time of introduction to remote monitoring. We did not detect difference in the risk of inappropriate therapies between the SC and DC discriminator groups (HR 2.274; 95% CI 0.437-11.815; p=0.329), and we did not find difference in the predefined sensitivity analysis between the two groups (HR 2.177; 95% CI 0.254-18.664; p=0.478). Conclusions Our data suggest that there is no significant difference in the performance of tachyarrhythmia discrimination between single- and dual-chamber discriminators. The findings of the present study support single-chamber discriminators as a viable alternative even for patients with implanted dual-chamber devices.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.583
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single- versus dual-chamber ICD discriminators for tachyarrhythmia detection: a remote monitoring based, single-center study

László Sághy, Tamás Szili‐Törok, Róbert Pap, M Miklos et al.
EP Europace
ECG Monitoring and Analysis
article

Single- versus dual-chamber ICD discriminators for tachyarrhythmia detection: a remote monitoring based, single-center study

László Sághy, Tamás Szili‐Törok, Róbert Pap, M Miklos, D. Fodor, Attila Makai, A Benak, Attila Nemes, Máté Vámos, Flóra Diána Gausz, Gábor Bencsik, Dóra Krányák
article en

Abstract

Abstract Background Implantable cardioverter defibrillator (ICD) systems are available in both single-chamber (SC) and dual-chamber (DC) configurations, with discrimination functions varying accordingly. Although expert opinion generally suggests that modern SC discriminators equipped with morphology detection algorithms are equally effective to DC systems in tachyarrhythmia discrimination, only limited and contradictory data are available. In most previous reports the choice between SC or DC discrimination was determined by the number of the implanted leads. Purpose We aimed to assess the efficacy of SC vs. DC ICD discriminators in malignant tachyarrhythmias by performing a head-to-head comparison of devices from a single manufacturer, whose ICDs also include single-lead devices with a programmable option of SC or DC discriminators (VDD ICD). Methods Data from ICD recipients followed up with the Home Monitoring system were retrospectively analysed. As primary outcome we compared the risk of inappropriate therapy between patients, whose ICD was programmed to SC (i.e. Stability/Onset/MorphMatch) vs. DC (i.e. SMART) discrimination algorithms. A sensitivity analysis was also conducted including only patients into the SC discrimination group with activated morphology discriminator. Results A total of 211 patients (mean age 64±12, male 75%, primary prophylaxis 33%) were included. All patients had been implanted with an ICD from the same manufacturer (VVI: 62, VDD: 94, DDD: 14, CRT-D: 41), and were remotely followed up. Among these, 71 ICDs were programmed to SC, while 98 were programmed to apply DC discriminators. In the remaining 42 cases, only VF zone was programmed, therefore these patients were excluded from further analysis. Of the SC discriminator group, 35 (49%) patients were programmed to utilize morphology discriminator. There was no significant difference between the SC and DC groups in atrial (6±3 vs. 4±3 mV; p=0.062) or ventricular sensing (15±6 vs. 14±7 mV; p=0.781) at the time of introduction to remote monitoring. We did not detect difference in the risk of inappropriate therapies between the SC and DC discriminator groups (HR 2.274; 95% CI 0.437-11.815; p=0.329), and we did not find difference in the predefined sensitivity analysis between the two groups (HR 2.177; 95% CI 0.254-18.664; p=0.478). Conclusions Our data suggest that there is no significant difference in the performance of tachyarrhythmia discrimination between single- and dual-chamber discriminators. The findings of the present study support single-chamber discriminators as a viable alternative even for patients with implanted dual-chamber devices.

EP EuropaceVol. 27(Supplement_1)
University of Szeged (HU)
Openalex Percentile: Top 80%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.