Abstract Background The catheter ablation (CA) has become the cornerstone for managing ventricular arrhythmias (VA). Field technical engineers (FTEs) operate the electroanatomical mapping (EAM) systems on-site in the majority of electrophysiology (EP) labs. The FTEs typically have to travel between different hospitals due to a shortage of qualified workers and the procedures need to be scheduled ahead of time. The use of remote support (RS) to guide VA ablations has the potential to increase flexibility, reduce travel times, maximise healthcare resources. Purpose To evaluate the safety and feasibility of RS as compared to on-site support guided CA for VA. Methods Consecutive patients who underwent ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation using RS were included (RS group). An equal number of patients matched for the type of procedure, receiving on-site assistance made up the control group. The RS guided three-dimensional (3D) mapping was obtained by connecting the EAM software with an integrated audio-visual solution. High-resolution cameras and headphones with a stable internet connection made it possible for the operator and the FTE, who worked solely from home office, to communicate. The hospital's electronic system was checked for readmissions, unscheduled ambulatory presentations, and emergency department (ED) visits within 30 days postprocedural. Results Between September 2022 and August 2024, a total of 53 patients underwent VT (43%) or PVC (57%) ablation in our centre using RS and were compared to 53 patients undergoing the same procedures with on-site support. There was no difference between the two groups regarding the demographic data. The median procedure time was 135.5 (105.8, 167.5) minutes in the RS group and 143.0 (116.5, 166.5) minutes in the control group (p=0.718), while the fluoroscopy time was 10.6 (6.3, 13.0) and 7.0 (4.6, 10.0) minutes respectively (p=0.011). The RS group achieved a procedural success of 98%, compared to 100% in the on-site group. In the RS group, eight patients underwent epicardial VT ablation and another one bipolar ablation for VT storm. No major technical issues or changes to on-site support were reported. Two (3.7%) intraprocedural complications were noted among the RS patients, while three (5.6%) complications occurred in the control group (p=0.618). A total of 22.6% of the RS and 18.8% of the control patients developed complications until discharge. Six (11.3%) patients in the RS group and three (5.6%) in the control group had ED visits, while three patients of each group had an unplanned ambulatory presentation. A total of 4% of the patients in the RS group and 7.5% of those in the control group were hospitalised postprocedural. The RS procedures reduced the CO2 emissions with 5.2 tons. Conclusion This is the largest study on the safety and feasibility of RS VA ablations. The RS approach contributes to a more sustainable environment while optimizing healthcare resources.Table 1.Demographic and procedural data Table 2.Peri- and postprocedural complic

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.851
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital health in the EP lab: early experiences, safety, feasibility and sustainibility of remote support for complex ablations procedures - results of the REMOTE-VA Study

Roland Richard Tilz, J P Wenzel, Karl‐Heinz Kück, Emel Yaman et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Digital health in the EP lab: early experiences, safety, feasibility and sustainibility of remote support for complex ablations procedures - results of the REMOTE-VA Study

Roland Richard Tilz, J P Wenzel, Karl‐Heinz Kück, Emel Yaman, Charlotte Eitel, Julia Vogler, Christian-Hendrik H. Heeger, Roman Mamaev, S S Popescu, B I Botezat
article en

Abstract

Abstract Background The catheter ablation (CA) has become the cornerstone for managing ventricular arrhythmias (VA). Field technical engineers (FTEs) operate the electroanatomical mapping (EAM) systems on-site in the majority of electrophysiology (EP) labs. The FTEs typically have to travel between different hospitals due to a shortage of qualified workers and the procedures need to be scheduled ahead of time. The use of remote support (RS) to guide VA ablations has the potential to increase flexibility, reduce travel times, maximise healthcare resources. Purpose To evaluate the safety and feasibility of RS as compared to on-site support guided CA for VA. Methods Consecutive patients who underwent ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation using RS were included (RS group). An equal number of patients matched for the type of procedure, receiving on-site assistance made up the control group. The RS guided three-dimensional (3D) mapping was obtained by connecting the EAM software with an integrated audio-visual solution. High-resolution cameras and headphones with a stable internet connection made it possible for the operator and the FTE, who worked solely from home office, to communicate. The hospital's electronic system was checked for readmissions, unscheduled ambulatory presentations, and emergency department (ED) visits within 30 days postprocedural. Results Between September 2022 and August 2024, a total of 53 patients underwent VT (43%) or PVC (57%) ablation in our centre using RS and were compared to 53 patients undergoing the same procedures with on-site support. There was no difference between the two groups regarding the demographic data. The median procedure time was 135.5 (105.8, 167.5) minutes in the RS group and 143.0 (116.5, 166.5) minutes in the control group (p=0.718), while the fluoroscopy time was 10.6 (6.3, 13.0) and 7.0 (4.6, 10.0) minutes respectively (p=0.011). The RS group achieved a procedural success of 98%, compared to 100% in the on-site group. In the RS group, eight patients underwent epicardial VT ablation and another one bipolar ablation for VT storm. No major technical issues or changes to on-site support were reported. Two (3.7%) intraprocedural complications were noted among the RS patients, while three (5.6%) complications occurred in the control group (p=0.618). A total of 22.6% of the RS and 18.8% of the control patients developed complications until discharge. Six (11.3%) patients in the RS group and three (5.6%) in the control group had ED visits, while three patients of each group had an unplanned ambulatory presentation. A total of 4% of the patients in the RS group and 7.5% of those in the control group were hospitalised postprocedural. The RS procedures reduced the CO2 emissions with 5.2 tons. Conclusion This is the largest study on the safety and feasibility of RS VA ablations. The RS approach contributes to a more sustainable environment while optimizing healthcare resources.Table 1.Demographic and procedural data Table 2.Peri- and postprocedural complic

EP EuropaceVol. 27(Supplement_1)
Asklepios Klinik Altona (DE), University Hospital Schleswig-Holstein (DE), University of Lübeck (DE)
Openalex Percentile: Top 80%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.