Evaluation of qt prolongation in patients following conduction system pacing implantation

Abstract Background Conduction system pacing is becoming increasingly popular as a pacing technique; however, its impact on repolarization, particularly on QT interval prolongation, remains unclear. Purpose This study aimed to evaluate the effect of conduction system pacing on the QT interval. Methods We conducted a retrospective review of all patients who received a left bundle branch lead at two centers between January 1, 2022, and June 30, 2024. Patients with left bundle pacing were included if they: identified as having deep septal or left bundle pacing (satisfying 2 of 3 markers—LVAT <80 ms, R’ in V1, PR1R6 >30 ms) and had a prolonged corrected QT interval (QTc >550 ms). Demographic and clinical data were collected through electronic medical records. Results From 597 patients who received a 3830 lead, 14 patients with left bundle branch pacing were identified as having QTc >550 ms (mean age 82 ± 6 years, 5 females). Nine patients received their device for complete heart block, 3 for tachy-brady and one after AV [MG1] node ablation. The average ejection fraction was 47 ± 13%. Post-implant ECG analysis showed an average QRS width of 127 ± 14 ms, an average QTc interval of 584 ± 28 ms, and an average heart rate of 74 ± 14 bpm. Notably, one patient experienced Torsades de Pointes three hours post-AV node ablation, with a QT interval of 600 ms that persisted for two weeks post-implant. All patients survived, with a mean follow-up period of 609 ± 470 days. Conclusion QT prolongation can occur following the placement of a conduction system pacing lead, which may elevate the risk of Torsades de Pointes post-implantation. In cases of prolonged QT, increasing heart rate may help to reduce the QT interval, though it may not fully normalize it. QT prolongation may persist for more than two weeks post-implant. Clinicians should be mindful of the potential for QT prolongation with conduction system pacing and consider closer follow-up until QT normalizes.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.659
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of qt prolongation in patients following conduction system pacing implantation

F.A.Y.A.L.A. VALANI, Mehrdad Golian, L Ayala Valani, Mohammad Asif et al.
EP Europace
Cardiac pacing and defibrillation studies
article

Evaluation of qt prolongation in patients following conduction system pacing implantation

F.A.Y.A.L.A. VALANI, Mehrdad Golian, L Ayala Valani, Mohammad Asif, Djalal Fakim, F. Ayala‐Paredes, Ghaith Almidani
article en

Abstract

Abstract Background Conduction system pacing is becoming increasingly popular as a pacing technique; however, its impact on repolarization, particularly on QT interval prolongation, remains unclear. Purpose This study aimed to evaluate the effect of conduction system pacing on the QT interval. Methods We conducted a retrospective review of all patients who received a left bundle branch lead at two centers between January 1, 2022, and June 30, 2024. Patients with left bundle pacing were included if they: identified as having deep septal or left bundle pacing (satisfying 2 of 3 markers—LVAT <80 ms, R’ in V1, PR1R6 >30 ms) and had a prolonged corrected QT interval (QTc >550 ms). Demographic and clinical data were collected through electronic medical records. Results From 597 patients who received a 3830 lead, 14 patients with left bundle branch pacing were identified as having QTc >550 ms (mean age 82 ± 6 years, 5 females). Nine patients received their device for complete heart block, 3 for tachy-brady and one after AV [MG1] node ablation. The average ejection fraction was 47 ± 13%. Post-implant ECG analysis showed an average QRS width of 127 ± 14 ms, an average QTc interval of 584 ± 28 ms, and an average heart rate of 74 ± 14 bpm. Notably, one patient experienced Torsades de Pointes three hours post-AV node ablation, with a QT interval of 600 ms that persisted for two weeks post-implant. All patients survived, with a mean follow-up period of 609 ± 470 days. Conclusion QT prolongation can occur following the placement of a conduction system pacing lead, which may elevate the risk of Torsades de Pointes post-implantation. In cases of prolonged QT, increasing heart rate may help to reduce the QT interval, though it may not fully normalize it. QT prolongation may persist for more than two weeks post-implant. Clinicians should be mindful of the potential for QT prolongation with conduction system pacing and consider closer follow-up until QT normalizes.

EP EuropaceVol. 27(Supplement_1)
University of Ottawa (CA), Centre Hospitalier Universitaire de Sherbrooke (CA)
Openalex Percentile: Top 80%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.