Abstract Background Leadless pacemaker (LP) has recently gained popularity due to its ease of implantation and absence of lead-related complications. However, limited data exists comparing the risk of pacing-induced cardiomyopathy (PiCM) between LP and conventional transvenous pacemakers (TVP). Given its septum-oriented implantation site, LP may theoretically reduce PiCM occurrence compared to TVP. Purpose This study aimed to evaluate the comparative risk of PiCM between LP and TVP Methods This retrospective cohort study evaluated 348 patients (130 LP, 218 TVP) for PiCM occurrence. PiCM was defined as new-onset left ventricular (LV) systolic dysfunction (LV ejection fraction < 50% on follow-up echocardiography) with a ≥ 10% decrease in LV ejection fraction from baseline, in the absence of other identifiable causes of LV dysfunction. Primary outcome was PiCM incidence. Secondary outcomes included heart failure hospitalization and all-cause mortality. Results Mean age of the study population was 71.2 ± 13.2 years, with 52% male patients. Baseline characteristics and echocardiographic parameters showed no significant differences between groups. Paced QRS duration was comparable between LP and TVP groups (154.6 ± 17.1 vs 152.8 ± 15.7ms, P=0.329). PiCM developed in 13 (10%) LP patients and 26 (11.9%) TVP patients after a median follow-up of 430.0 days (interquartile range: 254.0-499.0 days) and showed no significant group difference (P=0.707). Delta LV ejection fraction showed no significant difference between LP and TVP groups (3.5 ± 11.2% vs 2.5 ± 11.3%, P=0.396). Secondary outcomes including heart failure admissions (6.2% vs 4.1%, P=0.691) and all-cause mortality (7.7% vs 6.0%, P=0.685) were similar between groups. Conclusions Despite theoretical advantages of septal pacing, LP demonstrated similar PiCM risk compared to TVP. These findings suggest that pacemaker type may not significantly influence the development of PiCM. Larger prospective studies with longer follow-up periods are needed to confirm these results and evaluate long-term outcomes.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.574
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of pacing induced cardiomyopathy following leadless vs conventional pacemaker implantation

Soon‐Jung Park, Jae‐Sun Uhm, Yong‐Jae Lee, Young Keun On et al.
EP Europace
Cardiac pacing and defibrillation studies
article

Comparison of pacing induced cardiomyopathy following leadless vs conventional pacemaker implantation

Soon‐Jung Park, Jae‐Sun Uhm, Yong‐Jae Lee, Young Keun On, Kibog Park, Jaeryung Kim, Young‐Hoon Kim
article en

Abstract

Abstract Background Leadless pacemaker (LP) has recently gained popularity due to its ease of implantation and absence of lead-related complications. However, limited data exists comparing the risk of pacing-induced cardiomyopathy (PiCM) between LP and conventional transvenous pacemakers (TVP). Given its septum-oriented implantation site, LP may theoretically reduce PiCM occurrence compared to TVP. Purpose This study aimed to evaluate the comparative risk of PiCM between LP and TVP Methods This retrospective cohort study evaluated 348 patients (130 LP, 218 TVP) for PiCM occurrence. PiCM was defined as new-onset left ventricular (LV) systolic dysfunction (LV ejection fraction < 50% on follow-up echocardiography) with a ≥ 10% decrease in LV ejection fraction from baseline, in the absence of other identifiable causes of LV dysfunction. Primary outcome was PiCM incidence. Secondary outcomes included heart failure hospitalization and all-cause mortality. Results Mean age of the study population was 71.2 ± 13.2 years, with 52% male patients. Baseline characteristics and echocardiographic parameters showed no significant differences between groups. Paced QRS duration was comparable between LP and TVP groups (154.6 ± 17.1 vs 152.8 ± 15.7ms, P=0.329). PiCM developed in 13 (10%) LP patients and 26 (11.9%) TVP patients after a median follow-up of 430.0 days (interquartile range: 254.0-499.0 days) and showed no significant group difference (P=0.707). Delta LV ejection fraction showed no significant difference between LP and TVP groups (3.5 ± 11.2% vs 2.5 ± 11.3%, P=0.396). Secondary outcomes including heart failure admissions (6.2% vs 4.1%, P=0.691) and all-cause mortality (7.7% vs 6.0%, P=0.685) were similar between groups. Conclusions Despite theoretical advantages of septal pacing, LP demonstrated similar PiCM risk compared to TVP. These findings suggest that pacemaker type may not significantly influence the development of PiCM. Larger prospective studies with longer follow-up periods are needed to confirm these results and evaluate long-term outcomes.

EP EuropaceVol. 27(Supplement_1)
Yonsei University (KR), Samsung Medical Center (KR), Kyung Hee University Dental Hospital (KR), Sungkyunkwan University (KR)
Openalex Percentile: Top 80%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.