Comparison of hemolysis induced by different pulsed-field ablation systems

Abstract Background Pulsed-Field Ablation (PFA) is an innovative ablation technology, which, as a side effect, causes dose-dependent hemolysis. Currently, three PFA systems are commercially available in Europe: A pentaspline catheter, a lattice-tip focal catheter, and a variable loop circular catheter. Purpose All previous Studies investigating hemolysis during PFA have utilized a pentaspline catheter system. We aimed to provide the first retrospective comparison of hemolysis levels among all currently available PFA systems, and to examine dose-dependency across these different platforms. Methods From our prospective atrial fibrillation ablation registry, we included all patients treated with the lattice-tip focal (n=18) or variable loop circular (n=27) catheter. Additionally, we randomly included thirty patients treated with the pentaspline catheter within the same time period. Demographic and procedural data were obtained through chart review. For each procedure, we recorded the number of PFA applications. Routine measurements of creatinine and hemolysis markers were taken before and one day after the ablation procedure. For statistical evaluation, we applied Fisher’s exact test, the Kruskal-Wallis rank sum test, or the pairwise Wilcoxon test, as appropriate. Results The median age of the 75 included patients was 69 years, with 34 (25%) being women. The median number of applications was 46 for the lattice-tip focal catheter, 36 for the pentaspline catheter, and 21 for the variable loop circular catheter. Baseline levels of creatinine and hemolysis markers were similar across groups. The overall decrease in haptoglobin levels was more pronounced in cases treated with the pentaspline and variable loop circular catheter compared to the lattice-tip focal catheter (-0.68 ± 0.37 g/l, -0.60 ± 0.29 g/l, -0.23 ± 0.21 g/l, respectively; p < 0.0005; Figure and Table). The decrease in haptoglobin per application was different between the groups (-16.9 ± 8.5 mg/l, -28.1 ± 13.6 mg/l, -6.4 ± 8.7 mg/l, respectively; p < 0.0001; Figure and Table). The increase in LDH followed the same pattern (70.0 ± 65.8, 40.3 ± 64.1, 25.6 ± 36.3, respectively; p < 0.05; Table). No hemolysis-related complications occurred, and creatinine levels remained unchanged post-procedure compared to pre-procedure. Conclusions The extent of hemolysis induced by PFA procedures and per PFA application varies across different PFA platforms. Focal PFA catheters cause less hemolysis per procedure and per application than large-footprint PFA catheters.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.444
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of hemolysis induced by different pulsed-field ablation systems

Laurent Roten, Thomas Kueffer, Boldizsar Kovacs, George N. Thalmann et al.
EP Europace
Laser-induced spectroscopy and plasma
article

Comparison of hemolysis induced by different pulsed-field ablation systems

Laurent Roten, Thomas Kueffer, Boldizsar Kovacs, George N. Thalmann, Nikola Kozhuharov, Fabian Noti, Andreas Haeberlin, Hildegard Tanner, Tobias Reichlin, V Spahiu, Johannes Bruss
article en

Abstract

Abstract Background Pulsed-Field Ablation (PFA) is an innovative ablation technology, which, as a side effect, causes dose-dependent hemolysis. Currently, three PFA systems are commercially available in Europe: A pentaspline catheter, a lattice-tip focal catheter, and a variable loop circular catheter. Purpose All previous Studies investigating hemolysis during PFA have utilized a pentaspline catheter system. We aimed to provide the first retrospective comparison of hemolysis levels among all currently available PFA systems, and to examine dose-dependency across these different platforms. Methods From our prospective atrial fibrillation ablation registry, we included all patients treated with the lattice-tip focal (n=18) or variable loop circular (n=27) catheter. Additionally, we randomly included thirty patients treated with the pentaspline catheter within the same time period. Demographic and procedural data were obtained through chart review. For each procedure, we recorded the number of PFA applications. Routine measurements of creatinine and hemolysis markers were taken before and one day after the ablation procedure. For statistical evaluation, we applied Fisher’s exact test, the Kruskal-Wallis rank sum test, or the pairwise Wilcoxon test, as appropriate. Results The median age of the 75 included patients was 69 years, with 34 (25%) being women. The median number of applications was 46 for the lattice-tip focal catheter, 36 for the pentaspline catheter, and 21 for the variable loop circular catheter. Baseline levels of creatinine and hemolysis markers were similar across groups. The overall decrease in haptoglobin levels was more pronounced in cases treated with the pentaspline and variable loop circular catheter compared to the lattice-tip focal catheter (-0.68 ± 0.37 g/l, -0.60 ± 0.29 g/l, -0.23 ± 0.21 g/l, respectively; p < 0.0005; Figure and Table). The decrease in haptoglobin per application was different between the groups (-16.9 ± 8.5 mg/l, -28.1 ± 13.6 mg/l, -6.4 ± 8.7 mg/l, respectively; p < 0.0001; Figure and Table). The increase in LDH followed the same pattern (70.0 ± 65.8, 40.3 ± 64.1, 25.6 ± 36.3, respectively; p < 0.05; Table). No hemolysis-related complications occurred, and creatinine levels remained unchanged post-procedure compared to pre-procedure. Conclusions The extent of hemolysis induced by PFA procedures and per PFA application varies across different PFA platforms. Focal PFA catheters cause less hemolysis per procedure and per application than large-footprint PFA catheters.

EP EuropaceVol. 27(Supplement_1)
University Hospital of Bern (CH)
Openalex Percentile: Top 88%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.