Procedural characteristics of left atrial ablation procedures using a novel lattice-tip catheter

Abstract Background An innovative mapping and ablation large focal tip catheter that can toggle between pulsed field ablation (PFA) and radiofrequency (RF) integrated into a novel 3D mapping-platform has been introduced. So far, details on procedural characteristics are limited. Methods All consecutive patients undergoing left atrial (LA) ablation procedures for atrial fibrillation or atrial tachycardias with the new system were analyzed. All patients provided written informed consent and were enrolled in our prospective TRUST Registry. Results A total of 63 patients were enrolled, 39/63 (61.9%) underwent index pulmonary vein isolation (PVI) and 24/63 (38%) repeat procedures. Total mapping time was 23.3 ± 8.9 minutes (min, mean ± SD), recorded electrograms 4046 ± 1246, LA volume 169 ± 44 ml. In 51/63 (81%) patients, including 39 index PVI and 12 repeat procedures, complete PVI was achieved with first pass isolation using PFA only. Ablation time was 17.7 ± 6.9 min with 43.4 ± 10.5 PF applications for lateral PVs and 15.6 ± 7.4 min and 41.7 ± 11.2 PF applications for septal PVs. In 48/63 (76%) patients, additional LA linear lesion sets were performed: 25 anterior lines (all blocked, 8/25 (32%) RF only, 17/25 (68%) PFA and RF, mean ablation time 8.3 ± 6.2 min), 9 mitral isthmus lines (all blocked, 4/9 (44%) RF only, 5/9 (56%) PFA and RF, 2/9 (22%) additionally PFA applied within the coronary sinus, mean ablation time 17 ± 16.6 min), 25 posterior box lesions (all isolated, all PFA only, mean ablation time 5.5 ± 3.9 min), 17 roof lines (all blocked, all PFA only, mean ablation time 2.6 ± 2.2 min). In 23/63 (37%) patients a cavotricuspid isthmus line was performed and blocked in all with RF only with a mean ablation time of 4.6 ± 6.5 min. In 1/63 (2%) patients RF applications were additionally applied in the right atrium to treat a focal AT. Ablation-related complications occurred in 1/63 (1.6%) patients (1 cardiac tamponade). Conclusion The novel focal RF/PF lattice-tip catheter enables rapid high-density left atrial mapping and effective and safe PVI, Re-PVI and creation of additional left arial lesion sets.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.353
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Procedural characteristics of left atrial ablation procedures using a novel lattice-tip catheter

Fabian Moser, Andreas Rillig, Laura Rottner, Moritz Nies et al.
EP Europace
Cardiac Arrhythmias and Treatments
article

Procedural characteristics of left atrial ablation procedures using a novel lattice-tip catheter

Fabian Moser, Andreas Rillig, Laura Rottner, Moritz Nies, I My, Paulus Kirchhof, Niklas Schenker, Bruno Reißmann, Feifan Ouyang, Marc D. Lemoine, Andreas Metzner, K Govorov
article en

Abstract

Abstract Background An innovative mapping and ablation large focal tip catheter that can toggle between pulsed field ablation (PFA) and radiofrequency (RF) integrated into a novel 3D mapping-platform has been introduced. So far, details on procedural characteristics are limited. Methods All consecutive patients undergoing left atrial (LA) ablation procedures for atrial fibrillation or atrial tachycardias with the new system were analyzed. All patients provided written informed consent and were enrolled in our prospective TRUST Registry. Results A total of 63 patients were enrolled, 39/63 (61.9%) underwent index pulmonary vein isolation (PVI) and 24/63 (38%) repeat procedures. Total mapping time was 23.3 ± 8.9 minutes (min, mean ± SD), recorded electrograms 4046 ± 1246, LA volume 169 ± 44 ml. In 51/63 (81%) patients, including 39 index PVI and 12 repeat procedures, complete PVI was achieved with first pass isolation using PFA only. Ablation time was 17.7 ± 6.9 min with 43.4 ± 10.5 PF applications for lateral PVs and 15.6 ± 7.4 min and 41.7 ± 11.2 PF applications for septal PVs. In 48/63 (76%) patients, additional LA linear lesion sets were performed: 25 anterior lines (all blocked, 8/25 (32%) RF only, 17/25 (68%) PFA and RF, mean ablation time 8.3 ± 6.2 min), 9 mitral isthmus lines (all blocked, 4/9 (44%) RF only, 5/9 (56%) PFA and RF, 2/9 (22%) additionally PFA applied within the coronary sinus, mean ablation time 17 ± 16.6 min), 25 posterior box lesions (all isolated, all PFA only, mean ablation time 5.5 ± 3.9 min), 17 roof lines (all blocked, all PFA only, mean ablation time 2.6 ± 2.2 min). In 23/63 (37%) patients a cavotricuspid isthmus line was performed and blocked in all with RF only with a mean ablation time of 4.6 ± 6.5 min. In 1/63 (2%) patients RF applications were additionally applied in the right atrium to treat a focal AT. Ablation-related complications occurred in 1/63 (1.6%) patients (1 cardiac tamponade). Conclusion The novel focal RF/PF lattice-tip catheter enables rapid high-density left atrial mapping and effective and safe PVI, Re-PVI and creation of additional left arial lesion sets.

EP EuropaceVol. 27(Supplement_1)
Universität Hamburg (DE), University Medical Center Hamburg-Eppendorf (DE)
Openalex Percentile: Top 80%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.