Optimization of cardiac resynchronization therapy using fusion pacing algorithm - spectacular electrical imporvement does not trnslate into immediate hemodynamic result

Abstract Background Although Cardiac Resynchronization Therapy (CRT) has an established role in a treatment of heart failure, there is still a significant proportion of non-responders even in properly selected CRT recipients. Optimization of CRT pacing is one of possibilities to improve the effect. Fusion pacing algorithm allow for self-excitation of RV combined with left ventricular (LV) pacing, thus leading to further improvement of LV contraction synchrony compared to simultaneous biventricular pacing Aim The aim of the study was to assess the acute, beat to beat effect of standard BiV vs fusion-pacing on myocardial function as assessed by standard and speckle tracking echocardiography in HF patients with LBBB. Methods 28 heart failure patients (22 men and 6 women) with EF<35% and LBBB (QRS>150ms) and CRT-D (Abbott) had an echocardiographic assessment directly after device implantation and echo parameters (including left atrial strain, left ventricular strain, TAPSE, mitral and tricuspid valve function and cardiac output) were measured in 5 minutes interval at 3 different settings: pacing off, simultaneous BIV pacing and fusion-pacing (Abbott’s sync-AV algorithm). Results In our study CRT resulted in shortening od QRS complex from 169±19ms to 131±17ms for standard BiV pacing and further reduction to 118±16ms for fusion pacing (p<0.05). The acute effect of QRS shortening did not affect GLS (-9.15±3.05 vs -9.39±3.02 vs -9.13±3.65, p=NS), but affected segmental strain changes causing more homogenous contractility of LV. Also it did not affect stroke volume (67,5±17.5ml vs 68,4±14.82ml vs 68,5±16.70ml p=NS) and did not translate to changes in LA strain, LA area or LA ejection fraction. Conclusion Spectacular changes in QRS duration visible in CRT patients just after implant, even more pronounced in fusion pacing-optimized patients are responsible for more homogenous pattern of LV contractility, but do not immediately improve stroke volume, global LV strain and LA function immediately. Longer observation is required for improved electrical parameters to translate into hemodynamic effect in CRT patients.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-05-01
DOI
https://doi.org/10.1093/europace/euaf085.617
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of cardiac resynchronization therapy using fusion pacing algorithm - spectacular electrical imporvement does not trnslate into immediate hemodynamic result

Grzegorz Smołka, Michał Kucio, Mariusz Bałys, Tomasz Skowerski et al.
EP Europace
Cardiac pacing and defibrillation studies
article

Optimization of cardiac resynchronization therapy using fusion pacing algorithm - spectacular electrical imporvement does not trnslate into immediate hemodynamic result

Grzegorz Smołka, Michał Kucio, Mariusz Bałys, Tomasz Skowerski, Andrzej Kułach
article en

Abstract

Abstract Background Although Cardiac Resynchronization Therapy (CRT) has an established role in a treatment of heart failure, there is still a significant proportion of non-responders even in properly selected CRT recipients. Optimization of CRT pacing is one of possibilities to improve the effect. Fusion pacing algorithm allow for self-excitation of RV combined with left ventricular (LV) pacing, thus leading to further improvement of LV contraction synchrony compared to simultaneous biventricular pacing Aim The aim of the study was to assess the acute, beat to beat effect of standard BiV vs fusion-pacing on myocardial function as assessed by standard and speckle tracking echocardiography in HF patients with LBBB. Methods 28 heart failure patients (22 men and 6 women) with EF<35% and LBBB (QRS>150ms) and CRT-D (Abbott) had an echocardiographic assessment directly after device implantation and echo parameters (including left atrial strain, left ventricular strain, TAPSE, mitral and tricuspid valve function and cardiac output) were measured in 5 minutes interval at 3 different settings: pacing off, simultaneous BIV pacing and fusion-pacing (Abbott’s sync-AV algorithm). Results In our study CRT resulted in shortening od QRS complex from 169±19ms to 131±17ms for standard BiV pacing and further reduction to 118±16ms for fusion pacing (p<0.05). The acute effect of QRS shortening did not affect GLS (-9.15±3.05 vs -9.39±3.02 vs -9.13±3.65, p=NS), but affected segmental strain changes causing more homogenous contractility of LV. Also it did not affect stroke volume (67,5±17.5ml vs 68,4±14.82ml vs 68,5±16.70ml p=NS) and did not translate to changes in LA strain, LA area or LA ejection fraction. Conclusion Spectacular changes in QRS duration visible in CRT patients just after implant, even more pronounced in fusion pacing-optimized patients are responsible for more homogenous pattern of LV contractility, but do not immediately improve stroke volume, global LV strain and LA function immediately. Longer observation is required for improved electrical parameters to translate into hemodynamic effect in CRT patients.

EP EuropaceVol. 27(Supplement_1)
Medical University of Silesia (PL), Silesian Center for Heart Disease (PL)
Openalex Percentile: Top 80%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.