A Case Study on the Upgrading and Reconstruction of a Wastewater Treatment Plant in Hebei Province

<p>The effluent quality of a wastewater treatment plant (WWTP) in Hebei Province met the Class I-A standard of "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plants"(GB 18918-2002) (COD≤50 mg/L, TN≤15 mg/L, TP≤0.5 mg/L, NH3-N≤8 mg/L). However, under the guidance of energy conservation and emission reduction, existing WWTP were faced with some limitations, such as ineffective phosphorus and nitrogen removal, and upgrading treatment standards were required. Existing facilities are fully used and the synergistic strategy of enhancing biological efficiency and deepening treatment processes are adopted to achieve reduction of pollutants such as organics, nitrogen and phosphorus. The results show that the removal rates of COD, NH3-N, TP and TN reaches 94.6%, 99.8%, 86.5% and 98.0% respectively, even with the influent flow having increased by 50.8%, enabling the effluent to meet strict discharge standards (Class B standard of Beijing's "Comprehensive Discharge Standard for Water Pollutants") (DB11/307-2013) (COD≤40 mg/L, TN≤15 mg/L, TP≤0.4 mg/L, NH3-N≤5mg/L). The electricity consumption decreases by 11.4%, and the usage amounts of sodium acetate, disinfectant, and polyacrylamide respectively decrease by 41.4%, 10.8%, and 23.5%. This project significantly improves the local environment and protects downstream ecosystems. It provides valuable reference insights for similar WWTPs.</p>

Publication Details

Journal
Global NEST Journal
Published
2025-05-23
DOI
https://doi.org/10.30955/gnj.07245
Primary Topic
Regional Development and Environment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Case Study on the Upgrading and Reconstruction of a Wastewater Treatment Plant in Hebei Province

Global NEST Journal
Regional Development and Environment
article

A Case Study on the Upgrading and Reconstruction of a Wastewater Treatment Plant in Hebei Province

article en

Abstract

<p>The effluent quality of a wastewater treatment plant (WWTP) in Hebei Province met the Class I-A standard of "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plants"(GB 18918-2002) (COD≤50 mg/L, TN≤15 mg/L, TP≤0.5 mg/L, NH3-N≤8 mg/L). However, under the guidance of energy conservation and emission reduction, existing WWTP were faced with some limitations, such as ineffective phosphorus and nitrogen removal, and upgrading treatment standards were required. Existing facilities are fully used and the synergistic strategy of enhancing biological efficiency and deepening treatment processes are adopted to achieve reduction of pollutants such as organics, nitrogen and phosphorus. The results show that the removal rates of COD, NH3-N, TP and TN reaches 94.6%, 99.8%, 86.5% and 98.0% respectively, even with the influent flow having increased by 50.8%, enabling the effluent to meet strict discharge standards (Class B standard of Beijing's "Comprehensive Discharge Standard for Water Pollutants") (DB11/307-2013) (COD≤40 mg/L, TN≤15 mg/L, TP≤0.4 mg/L, NH3-N≤5mg/L). The electricity consumption decreases by 11.4%, and the usage amounts of sodium acetate, disinfectant, and polyacrylamide respectively decrease by 41.4%, 10.8%, and 23.5%. This project significantly improves the local environment and protects downstream ecosystems. It provides valuable reference insights for similar WWTPs.</p>

Global NEST Journal
Openalex Percentile: Top 85%
Regional Development and Environment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.