A Semi-Analytical Study on Multiscale Porous Biocatalytic Electrodes in the Enzyme Reaction Process

A multiscale porous biocatalytic electrode’s oxidation of glucose is explained theoretically. The model that describes diffusion and response within a hydrogel film is composed by two non-linear differential equations. Approximate analytical findings of the glucose concentrations, current, and the oxidised mediator have been obtained via the new homotopy perturbation technique. Furthermore, an analytical calculation is performed to determine the ideal electrode thickness for the film by employing Ananthaswamy-Sivasankari Method (ASM). It also investigates how parameters affect current. Our approximate analytical expressions are validated by the numerical simulation (MATLAB).

Authors

Institutions

Publication Details

Journal
Communications in Mathematics and Applications
Published
2024-11-30
DOI
https://doi.org/10.26713/cma.v15i3.2821
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Semi-Analytical Study on Multiscale Porous Biocatalytic Electrodes in the Enzyme Reaction Process

V. Ananthaswamy, V. Vijayalakshmi, J. Anantha Jothi
Communications in Mathematics and Applications
Electrochemical sensors and biosensors
article

A Semi-Analytical Study on Multiscale Porous Biocatalytic Electrodes in the Enzyme Reaction Process

V. Ananthaswamy, V. Vijayalakshmi, J. Anantha Jothi
article en

Abstract

A multiscale porous biocatalytic electrode’s oxidation of glucose is explained theoretically. The model that describes diffusion and response within a hydrogel film is composed by two non-linear differential equations. Approximate analytical findings of the glucose concentrations, current, and the oxidised mediator have been obtained via the new homotopy perturbation technique. Furthermore, an analytical calculation is performed to determine the ideal electrode thickness for the film by employing Ananthaswamy-Sivasankari Method (ASM). It also investigates how parameters affect current. Our approximate analytical expressions are validated by the numerical simulation (MATLAB).

Communications in Mathematics and ApplicationsVol. 15(3)
Madurai Kamaraj University (IN)
Openalex Percentile: Top 72%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.