Digital evaluation of the apical 3 mm portion of various implant designs on the surface area in contact with bone

A 3–5 mm apical anchorage length is commonly accepted to achieve primary stability in immediate implant placement and restoration (IIPR). However, this linear criterion overlooks the variability of current implant designs. The main objective was to use digital technologies to evaluate the endosseous surface of the implant when the apical anchorage is 3 mm using digital technologies. Fifty implants meeting defined inclusion criteria (13 mm length, internal connection, 3.3–4.2 mm occlusal diameter) were analyzed. 3D models were processed to calculate total surface area (TSA), functional surface area (FSA; excluding cutting flutes), and cylindrical surface area (CSA) for full implants and their apical 3 mm portions. Comparisons used paired t-tests or Wilcoxon signed-rank tests. This study is purely digital and includes no in vitro or clinical validation. FSA was 7% (SD 5%) smaller than TSA for full implants and 19% (SD 15%) smaller for the apical portions (p < 0.001). Apical FSA ranged from 14.37 to 50.24 mm 2 , averaging 17% of total FSA. Compared to CSA, FSA was 7% (SD 10%) larger for full implants and 38% (SD 19%) smaller for the apex (p < 0.001). A fixed 3 mm apical anchorage does not reflect functional surface area availability reliably. Apical FSA varies substantially by implant design, highlighting the need to consider apical geometry during planning. Rather than relying solely on linear anchorage depth, clinicians should consider apical implant design and its influence on functional surface area as one of several factors guiding implant selection and drilling protocol adaptation in IIPR. Highlights : • Considerations on placing an implant 3 mm beyond the extraction socket. • The apical 3 mm portion of implants shows wide variability. • Cutting flutes are associated with lower functional surface area (FSA) in the apical 3 mm portion. • The implant apex design and surface area should be considered when planning for IIPR.

Authors

Institutions

Publication Details

Journal
Digital Dentistry Journal
Published
2025-05-22
DOI
https://doi.org/10.1016/j.ddj.2025.100021
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital evaluation of the apical 3 mm portion of various implant designs on the surface area in contact with bone

Benjamin Cortasse, Antoine Galibourg, Philippe Campan, Anthony Lebon et al.
4 links
Digital Dentistry Journal
Dental Implant Techniques and Outcomes
article

Digital evaluation of the apical 3 mm portion of various implant designs on the surface area in contact with bone

Benjamin Cortasse, Antoine Galibourg, Philippe Campan, Anthony Lebon, Victor Emonet-Denand
article en

Abstract

A 3–5 mm apical anchorage length is commonly accepted to achieve primary stability in immediate implant placement and restoration (IIPR). However, this linear criterion overlooks the variability of current implant designs. The main objective was to use digital technologies to evaluate the endosseous surface of the implant when the apical anchorage is 3 mm using digital technologies. Fifty implants meeting defined inclusion criteria (13 mm length, internal connection, 3.3–4.2 mm occlusal diameter) were analyzed. 3D models were processed to calculate total surface area (TSA), functional surface area (FSA; excluding cutting flutes), and cylindrical surface area (CSA) for full implants and their apical 3 mm portions. Comparisons used paired t-tests or Wilcoxon signed-rank tests. This study is purely digital and includes no in vitro or clinical validation. FSA was 7% (SD 5%) smaller than TSA for full implants and 19% (SD 15%) smaller for the apical portions (p < 0.001). Apical FSA ranged from 14.37 to 50.24 mm 2 , averaging 17% of total FSA. Compared to CSA, FSA was 7% (SD 10%) larger for full implants and 38% (SD 19%) smaller for the apex (p < 0.001). A fixed 3 mm apical anchorage does not reflect functional surface area availability reliably. Apical FSA varies substantially by implant design, highlighting the need to consider apical geometry during planning. Rather than relying solely on linear anchorage depth, clinicians should consider apical implant design and its influence on functional surface area as one of several factors guiding implant selection and drilling protocol adaptation in IIPR. Highlights : • Considerations on placing an implant 3 mm beyond the extraction socket. • The apical 3 mm portion of implants shows wide variability. • Cutting flutes are associated with lower functional surface area (FSA) in the apical 3 mm portion. • The implant apex design and surface area should be considered when planning for IIPR.

Digital Dentistry JournalVol. 2(2)
Université Fédérale de Toulouse Midi-Pyrénées (FR), Clinique Les Fontaines (FR)
Openalex Percentile: Top 85%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.