In recent years, owing to the demands of point-of-care tests (POCTs), sensors with the advantages of low cost, small dimensions, and precise detection have been widely developed. Extended-gate field-effect transistor (EGFET) devices stand out due to their simplified fabrication and excellent sensing performance. This study optimizes titanium nitride (TiN) sputtering as a gate material for a high-performance sensing membrane and integrates a custom-made quasi-reference electrode (C-qRE) onto the EGFET chip to develop a portable platform for detecting urinary tract stone-related biomarkers, including calcium ions (Ca<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup>) and urea. The optimized TiN membrane, fabricated under a nitrogen flow ratio of 60%, achieved a pH sensitivity of 59.4 mV/pH with linearity of 100%, and minimized drift (0.8 mV/hour) and hysteresis (1 mV). Calcium ion detection showed 27.2 mV/pCa sensitivity with 99.9% linearity, while urea detection demonstrated 32.9 mV/mM sensitivity across 0.3–3.7 mM. The C-qRE maintained pH sensitivity of 57.2 mV/pH over 240 days. Furthermore, a multiplexed constant-voltage constant-current (CVCC) readout system was implemented to enable simultaneous measurement of multiple sensors, providing a compact and reliable alternative to conventional systems. This novel EGFET-based device integrates a semiconductor quasi-reference electrode for multimarker detection, offering high sensitivity, stability, and portability, and holds significant promise for clinical and home monitoring, representing a major advance in POCT diagnostics.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-22
DOI
https://doi.org/10.1109/jsen.2025.3570755
Citations
1
Primary Topic
Semiconductor materials and devices
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Disposable Solid-State EGFET Chip Integrated With a Mini-Readout System for Multi-Ion and Urea Detection

Marcin Urbanowicz, Chaohui Wei, Dorota G. Pijanowska, E. Remiszewska et al.
1 citations
IEEE Sensors Journal
Semiconductor materials and devices
0.73
article

A Disposable Solid-State EGFET Chip Integrated With a Mini-Readout System for Multi-Ion and Urea Detection

Marcin Urbanowicz, Chaohui Wei, Dorota G. Pijanowska, E. Remiszewska, Chia‐Ming Yang, Chao‐Sung Lai, Fuad Ughi, Jia-Yuan Chang
article en
1 citations

Abstract

In recent years, owing to the demands of point-of-care tests (POCTs), sensors with the advantages of low cost, small dimensions, and precise detection have been widely developed. Extended-gate field-effect transistor (EGFET) devices stand out due to their simplified fabrication and excellent sensing performance. This study optimizes titanium nitride (TiN) sputtering as a gate material for a high-performance sensing membrane and integrates a custom-made quasi-reference electrode (C-qRE) onto the EGFET chip to develop a portable platform for detecting urinary tract stone-related biomarkers, including calcium ions (Ca<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup>) and urea. The optimized TiN membrane, fabricated under a nitrogen flow ratio of 60%, achieved a pH sensitivity of 59.4 mV/pH with linearity of 100%, and minimized drift (0.8 mV/hour) and hysteresis (1 mV). Calcium ion detection showed 27.2 mV/pCa sensitivity with 99.9% linearity, while urea detection demonstrated 32.9 mV/mM sensitivity across 0.3–3.7 mM. The C-qRE maintained pH sensitivity of 57.2 mV/pH over 240 days. Furthermore, a multiplexed constant-voltage constant-current (CVCC) readout system was implemented to enable simultaneous measurement of multiple sensors, providing a compact and reliable alternative to conventional systems. This novel EGFET-based device integrates a semiconductor quasi-reference electrode for multimarker detection, offering high sensitivity, stability, and portability, and holds significant promise for clinical and home monitoring, representing a major advance in POCT diagnostics.

IEEE Sensors JournalVol. 25(14)
Ming Chi University of Technology (TW), Chang Gung University of Science and Technology (TW), Chang Gung University (TW), Institute of Biocybernetics and Biomedical Engineering (PL), Polish Academy of Sciences (PL)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 28%
Semiconductor materials and devices
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.