COMPARATIVE AND OPTIMUM ANALYSIS FOR NUMBER OF COLD STANDBY UNITS FOR A SYSTEM WORKING WITH ONE OPERATIVE UNIT AND TWO TYPES OF FAULTS

A system with a single functional unit and one or two cold standby units is studied by developing two Models. In one of the two models, there is a provision for one cold standby unit, whereas in the other, the provision is for two cold standby units. The operative unit, whenever it fails, may either fail due to a major fault or a minor fault, which is revealed by carrying out an inspection. When the operative unit fails, the cold standby becomes operational with an activation time between the operative unit failing and the standby operating state. Reliability and profit analysis have been carried out for both two models. A comparative study has also been made between the two models to decide whether one or two cold standby units should be used for such a system, as far as the profitability aspect is concerned. The models have been examined using the regenerating point method.

Authors

Publication Details

Journal
JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES
Published
2025-05-14
DOI
https://doi.org/10.26782/jmcms.2025.05.00007
Primary Topic
Advanced Manufacturing and Logistics Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARATIVE AND OPTIMUM ANALYSIS FOR NUMBER OF COLD STANDBY UNITS FOR A SYSTEM WORKING WITH ONE OPERATIVE UNIT AND TWO TYPES OF FAULTS

Gulshan Taneja, Parveen Kumar, Anil Taneja
JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES
Advanced Manufacturing and Logistics Optimization
article

COMPARATIVE AND OPTIMUM ANALYSIS FOR NUMBER OF COLD STANDBY UNITS FOR A SYSTEM WORKING WITH ONE OPERATIVE UNIT AND TWO TYPES OF FAULTS

Gulshan Taneja, Parveen Kumar, Anil Taneja
article en

Abstract

A system with a single functional unit and one or two cold standby units is studied by developing two Models. In one of the two models, there is a provision for one cold standby unit, whereas in the other, the provision is for two cold standby units. The operative unit, whenever it fails, may either fail due to a major fault or a minor fault, which is revealed by carrying out an inspection. When the operative unit fails, the cold standby becomes operational with an activation time between the operative unit failing and the standby operating state. Reliability and profit analysis have been carried out for both two models. A comparative study has also been made between the two models to decide whether one or two cold standby units should be used for such a system, as far as the profitability aspect is concerned. The models have been examined using the regenerating point method.

JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCESVol. 20(5)
Openalex Percentile: Top 85%
Advanced Manufacturing and Logistics Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.