Validation of Protein A chromatography: orthogonal method with size exclusion chromatography validation for mAb titer analysis

Abstract Objectives After reviewing the reference product specifications, found that they include the SEC HPLC result but do not specify Protein A chromatography as a test. Although there is no record of reference product specifications, alternative methods are necessary, particularly for routine analysis of biotechnological products. Methods The SEC mobile phase consisted of 0.1 M sodium phosphate and 0.2 M saline buffer pH 6.80 run isocratically at a flow rate of 0.5 mL/min. The Protein A chromatography column was equilibrated (60 mM sodium phosphate buffer, pH 7.4 (binding buffer), 60 mM sodium phosphate buffer, pH 2.5 (elution buffer) gradient system) at 1 mL/min. Results The SEC HPLC method validation study was conducted, ranging from (0.01–2.0 mg/mL) 1.0 % (LLOQ level) to 200 %. The Protein A chromatography method between (0.0078 and 4.0 mg/mL) 0.78 % (LLOQ level) and 400 % linearity levels. In the linearity study, both ANOVA and Graphpad results were shown. Both bioanalytical methods were performed by establishing validation parameters for the mAb reference product in accordance with the ICH M10 guideline. Conclusions Additionally, the findings shed light on routine titer analysis of biotechnological products, as there is no documentation in the literature regarding Protein A chromatography validation.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Biochemistry
Published
2025-05-22
DOI
https://doi.org/10.1515/tjb-2024-0186
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Protein A chromatography: orthogonal method with size exclusion chromatography validation for mAb titer analysis

Ece Kök Yetimoğlu, N Ozdemir, Dilan Bicak, Nilüfer Çakır et al.
Turkish Journal of Biochemistry
Protein purification and stability
article

Validation of Protein A chromatography: orthogonal method with size exclusion chromatography validation for mAb titer analysis

Ece Kök Yetimoğlu, N Ozdemir, Dilan Bicak, Nilüfer Çakır, Aylin Özkan, Hatice Oncel, Elif Sahinkaya, Merve Elif Aslan
article en

Abstract

Abstract Objectives After reviewing the reference product specifications, found that they include the SEC HPLC result but do not specify Protein A chromatography as a test. Although there is no record of reference product specifications, alternative methods are necessary, particularly for routine analysis of biotechnological products. Methods The SEC mobile phase consisted of 0.1 M sodium phosphate and 0.2 M saline buffer pH 6.80 run isocratically at a flow rate of 0.5 mL/min. The Protein A chromatography column was equilibrated (60 mM sodium phosphate buffer, pH 7.4 (binding buffer), 60 mM sodium phosphate buffer, pH 2.5 (elution buffer) gradient system) at 1 mL/min. Results The SEC HPLC method validation study was conducted, ranging from (0.01–2.0 mg/mL) 1.0 % (LLOQ level) to 200 %. The Protein A chromatography method between (0.0078 and 4.0 mg/mL) 0.78 % (LLOQ level) and 400 % linearity levels. In the linearity study, both ANOVA and Graphpad results were shown. Both bioanalytical methods were performed by establishing validation parameters for the mAb reference product in accordance with the ICH M10 guideline. Conclusions Additionally, the findings shed light on routine titer analysis of biotechnological products, as there is no documentation in the literature regarding Protein A chromatography validation.

Turkish Journal of BiochemistryVol. 50(3)
Marmara University (TR)
Openalex Percentile: Top 90%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of Protein A chromatography: orthogonal method with size exclusion chromatography validation for mAb titer analysis — Ece Kök Yetimoğlu, N Ozdemir, et al. · Turkish Journal of Biochemistry (2025) | TGRS Research Map | TGRS