Effects of Excess Refrigerant Load on the COP of a Typical Air Conditioning System in the Tropics

For both home and commercial applications, air conditioner (AC) is given priority in design. When an AC system is fully charged with a predetermined amount of refrigerant, it functions at its best. Low charge results from refrigerant leaks and poor field maintenance, which lowers thermal performance and raises running costs. For best operation and cost savings, it is necessary to comprehend the air-conditioner's performance if it is not correctly charged. The impact of additional refrigerant load on the COP of a typical tropical AC system was investigated experimentally. The utilization of a used small-capacity window air conditioner with R-22 refrigerant is the main subject of this investigation. The data make it very evident that 100% is the ideal refrigerant charge. 3,500 J/s and 3.80 COP were the maximum cooling capacity and COP, respectively. Additionally, a high refrigerant load causes the air-conditioner's performance to decline.

Publication Details

Journal
International Journal of Science Architecture Technology and Environment
Published
2025-05-22
DOI
https://doi.org/10.63680/ijsate052593.76
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Excess Refrigerant Load on the COP of a Typical Air Conditioning System in the Tropics

International Journal of Science Architecture Technology and Environment
Refrigeration and Air Conditioning Technologies
article

Effects of Excess Refrigerant Load on the COP of a Typical Air Conditioning System in the Tropics

article en

Abstract

For both home and commercial applications, air conditioner (AC) is given priority in design. When an AC system is fully charged with a predetermined amount of refrigerant, it functions at its best. Low charge results from refrigerant leaks and poor field maintenance, which lowers thermal performance and raises running costs. For best operation and cost savings, it is necessary to comprehend the air-conditioner's performance if it is not correctly charged. The impact of additional refrigerant load on the COP of a typical tropical AC system was investigated experimentally. The utilization of a used small-capacity window air conditioner with R-22 refrigerant is the main subject of this investigation. The data make it very evident that 100% is the ideal refrigerant charge. 3,500 J/s and 3.80 COP were the maximum cooling capacity and COP, respectively. Additionally, a high refrigerant load causes the air-conditioner's performance to decline.

International Journal of Science Architecture Technology and Environment
Openalex Percentile: Top 89%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.