Scintillator decorrelation for self-supervised x-ray radiograph denoising

Abstract X-ray radiographs from industrial, medical, and laboratory x-ray equipment can degrade severely due to fast and/or low-dose acquisition, x-ray scatter, and electronic noise from the detector instrument. As a consequence, noise and artifacts propagate into computed tomography (CT) images. Recently, a new class of self-supervised deep learning methods, with Noise2Self and Noise2Void, demonstrated state-of-the-art denoising results on data sets of pixelwise statistically-independent noisy images. These methods, called blind-spot networks (BSNs), are promising for applications where clean training examples or pairs of noisy examples are unavailable. For x-ray imaging, however, the detection principle of x-ray scintillators leads to a spatially-correlated mix of Poisson and Gaussian noise, rendering BSNs ineffective. In this article, we propose and validate a denoising workflow that reverts the correlations by a direct deconvolution with an estimate of the scintillator point-response function . We show that it can restore the denoising performance of Noise2Self, and demonstrate it for dynamic sparse-view CT reconstruction of single-bubble gas-solids fluidized beds using a data set of unpaired noisy radiographs from cesium-iodine scintillator flat-panel detectors.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-05-22
DOI
https://doi.org/10.1088/1361-6501/addc06
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scintillator decorrelation for self-supervised x-ray radiograph denoising

Felix F. Lucka, Adriaan Graas
1 citations
Measurement Science and Technology
Medical Imaging Techniques and Applications
1.36
article

Scintillator decorrelation for self-supervised x-ray radiograph denoising

Felix F. Lucka, Adriaan Graas
article en
1 citations

Abstract

Abstract X-ray radiographs from industrial, medical, and laboratory x-ray equipment can degrade severely due to fast and/or low-dose acquisition, x-ray scatter, and electronic noise from the detector instrument. As a consequence, noise and artifacts propagate into computed tomography (CT) images. Recently, a new class of self-supervised deep learning methods, with Noise2Self and Noise2Void, demonstrated state-of-the-art denoising results on data sets of pixelwise statistically-independent noisy images. These methods, called blind-spot networks (BSNs), are promising for applications where clean training examples or pairs of noisy examples are unavailable. For x-ray imaging, however, the detection principle of x-ray scintillators leads to a spatially-correlated mix of Poisson and Gaussian noise, rendering BSNs ineffective. In this article, we propose and validate a denoising workflow that reverts the correlations by a direct deconvolution with an estimate of the scintillator point-response function . We show that it can restore the denoising performance of Noise2Self, and demonstrate it for dynamic sparse-view CT reconstruction of single-bubble gas-solids fluidized beds using a data set of unpaired noisy radiographs from cesium-iodine scintillator flat-panel detectors.

Measurement Science and TechnologyVol. 36(6)
Centrum Wiskunde & Informatica (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Openalex Percentile: Top 20%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.