A ferrofluid-based haptic guidance system for robot-assisted endovascular procedures

In the context of endovascular intervention, robot assistance provides improved instrument navigation, safety, and ergonomics compared to traditional surgical approaches. However, a significant challenge with these interventions is the lack of tactile feedback for surgeons, which is crucial for precise instrument manipulation. This paper introduces a novel concept for a ferrofluid-based haptic feedback system designed to potentially address this gap in robot-assisted endovascular surgeries. Leveraging the unique properties of ferrofluids, which alter their viscosity under magnetic fields, this system aims to mimic the tactile sensations that are otherwise lost in robotic surgeries. The study presents the development and validation of a ferrofluid-based system integrated within the CathBot, a robotic platform for endovascular procedures. The system utilizes ferrofluids in a teleoperated setup to provide real-time, intuitive feedback about instrument positioning, potentially enhancing surgical accuracy and safety. Experiments were conducted to evaluate the properties of the ferrofluids and their interaction with magnetic fields to create a responsive feedback mechanism. Results from structural experiments, force evaluations, and user studies indicate that ferrofluids have the potential to effectively providing tactile feedback through controlled magnetic fields, improving the surgeon's ability to detect and respond to contact points within the vasculature. Despite some challenges with fluid control and system integration, the preliminary outcomes are promising. The potential improvements include refining the feedback mechanism to better mimic natural tactile sensations and further integrating this technology with existing robotic systems to enhance operational efficiency and patient safety.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2025-05-22
DOI
https://doi.org/10.1007/s11701-025-02398-y
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A ferrofluid-based haptic guidance system for robot-assisted endovascular procedures

Saket Pradhan, Dennis Kundrat, Giulio Dagnino
1 citations
Journal of Robotic Surgery
Soft Robotics and Applications
0.67
article

A ferrofluid-based haptic guidance system for robot-assisted endovascular procedures

Saket Pradhan, Dennis Kundrat, Giulio Dagnino
article en
1 citations

Abstract

In the context of endovascular intervention, robot assistance provides improved instrument navigation, safety, and ergonomics compared to traditional surgical approaches. However, a significant challenge with these interventions is the lack of tactile feedback for surgeons, which is crucial for precise instrument manipulation. This paper introduces a novel concept for a ferrofluid-based haptic feedback system designed to potentially address this gap in robot-assisted endovascular surgeries. Leveraging the unique properties of ferrofluids, which alter their viscosity under magnetic fields, this system aims to mimic the tactile sensations that are otherwise lost in robotic surgeries. The study presents the development and validation of a ferrofluid-based system integrated within the CathBot, a robotic platform for endovascular procedures. The system utilizes ferrofluids in a teleoperated setup to provide real-time, intuitive feedback about instrument positioning, potentially enhancing surgical accuracy and safety. Experiments were conducted to evaluate the properties of the ferrofluids and their interaction with magnetic fields to create a responsive feedback mechanism. Results from structural experiments, force evaluations, and user studies indicate that ferrofluids have the potential to effectively providing tactile feedback through controlled magnetic fields, improving the surgeon's ability to detect and respond to contact points within the vasculature. Despite some challenges with fluid control and system integration, the preliminary outcomes are promising. The potential improvements include refining the feedback mechanism to better mimic natural tactile sensations and further integrating this technology with existing robotic systems to enhance operational efficiency and patient safety.

Journal of Robotic SurgeryVol. 19(1)
Fraunhofer-Einrichtung für Individualisierte Medizintechnik (DE), University of Twente (NL)
Openalex Percentile: Top 31%
Soft Robotics and Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.