The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia implants. Monolithic incisor and molar zirconia crowns (n = 8 per group) were cemented on either PEKK or zirconia screw-retained abutments on zirconia implants. Molar and incisor crowns were also cemented on screw-retained titanium abutments on titanium implants as control. All specimens were subjected to combined mechanical loading (1.2 × 106 cycles of 50 N, f = 1 Hz) and thermal cycling (2 × 3000 × 5°C/55°C cycles of 2 minutes). Complications, such as loosening of the crowns and fractures, were observed. The surviving specimens were subjected to a fracture test. Descriptive statistics were applied to complications, survival times, and fracture forces. The occurrence of complications depended significantly on location (anterior or posterior) and material (P < .0001). While the incisor test groups presented higher failure rates for both PEKK and zirconia abutments, the survival rates of the molar-shaped crowns of both test groups were comparable with those of the titanium control group. This highly significant interaction is caused by a substantial difference in location for PEKK and zirconia (P < .05). The titanium control group showed uniform performance independent of the simulated site. PEKK abutments showed high survival rates for in vitro simulated molar sites. Screw-retained zirconia abutments have shown higher complication rates, especially in simulated anterior sites. Neither zirconia nor PEKK abutments are recommended in clinical application for anterior indication.
Authors
- Sebastian Kühl (ORCID: https://orcid.org/0000-0002-3174-135X)
- Zeynab Ahmed
- Valentin Herber (ORCID: https://orcid.org/0000-0002-8278-6857)
- Marc Joos (ORCID: https://orcid.org/0000-0002-1774-997X)
- Roland Joos
- Martin Rosentritt (ORCID: https://orcid.org/0000-0002-5227-288X)
Institutions
- University of Basel (CH)
- FHNW University of Applied Sciences and Arts Northwestern Switzerland (CH)
- University Hospital Regensburg (DE)
Publication Details
- Journal
- Journal of Oral Implantology
- Published
- 2025-05-22
- DOI
- https://doi.org/10.1563/aaid-joi-d-25-00014
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00