The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study

This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia implants. Monolithic incisor and molar zirconia crowns (n = 8 per group) were cemented on either PEKK or zirconia screw-retained abutments on zirconia implants. Molar and incisor crowns were also cemented on screw-retained titanium abutments on titanium implants as control. All specimens were subjected to combined mechanical loading (1.2 × 106 cycles of 50 N, f = 1 Hz) and thermal cycling (2 × 3000 × 5°C/55°C cycles of 2 minutes). Complications, such as loosening of the crowns and fractures, were observed. The surviving specimens were subjected to a fracture test. Descriptive statistics were applied to complications, survival times, and fracture forces. The occurrence of complications depended significantly on location (anterior or posterior) and material (P < .0001). While the incisor test groups presented higher failure rates for both PEKK and zirconia abutments, the survival rates of the molar-shaped crowns of both test groups were comparable with those of the titanium control group. This highly significant interaction is caused by a substantial difference in location for PEKK and zirconia (P < .05). The titanium control group showed uniform performance independent of the simulated site. PEKK abutments showed high survival rates for in vitro simulated molar sites. Screw-retained zirconia abutments have shown higher complication rates, especially in simulated anterior sites. Neither zirconia nor PEKK abutments are recommended in clinical application for anterior indication.

Authors

Institutions

Publication Details

Journal
Journal of Oral Implantology
Published
2025-05-22
DOI
https://doi.org/10.1563/aaid-joi-d-25-00014
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study

Sebastian Kühl, Zeynab Ahmed, Valentin Herber, Marc Joos et al.
Journal of Oral Implantology
Dental Implant Techniques and Outcomes
article

The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study

Sebastian Kühl, Zeynab Ahmed, Valentin Herber, Marc Joos, Roland Joos, Martin Rosentritt
article en

Abstract

This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia implants. Monolithic incisor and molar zirconia crowns (n = 8 per group) were cemented on either PEKK or zirconia screw-retained abutments on zirconia implants. Molar and incisor crowns were also cemented on screw-retained titanium abutments on titanium implants as control. All specimens were subjected to combined mechanical loading (1.2 × 106 cycles of 50 N, f = 1 Hz) and thermal cycling (2 × 3000 × 5°C/55°C cycles of 2 minutes). Complications, such as loosening of the crowns and fractures, were observed. The surviving specimens were subjected to a fracture test. Descriptive statistics were applied to complications, survival times, and fracture forces. The occurrence of complications depended significantly on location (anterior or posterior) and material (P < .0001). While the incisor test groups presented higher failure rates for both PEKK and zirconia abutments, the survival rates of the molar-shaped crowns of both test groups were comparable with those of the titanium control group. This highly significant interaction is caused by a substantial difference in location for PEKK and zirconia (P < .05). The titanium control group showed uniform performance independent of the simulated site. PEKK abutments showed high survival rates for in vitro simulated molar sites. Screw-retained zirconia abutments have shown higher complication rates, especially in simulated anterior sites. Neither zirconia nor PEKK abutments are recommended in clinical application for anterior indication.

Journal of Oral ImplantologyVol. 51(4)
University of Basel (CH), FHNW University of Applied Sciences and Arts Northwestern Switzerland (CH), University Hospital Regensburg (DE)
Openalex Percentile: Top 85%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.