THE B-SCORE IS A NOVEL METRIC FOR MEASURING THE TRUE PERFORMANCE OF BLOOD PRESSURE ESTIMATION MODELS

Objective: Many novel blood pressure (BP) measurement technologies have been recently introduced into the market. Evaluating their measurement performance reliably and detecting important features of distinct technologies and devices is crucial for them to potentially reach clinical usability. To facilitate this, we developed a novel metric for the relative performance of blood pressure estimation systems (B-Score). Design and method: The B-Score sets absolute blood pressure estimation model performance in contrast to the dataset the model is tested upon. We calculate the B-Score based on inter- and intrapersonal variabilities within the dataset. To test the B-Score for reliable results and desired properties, we designed generic datasets with differing inter- and intrapersonal blood pressure variability. We then tested and validated the B-Score’s real-world functionality on large scale clinical datasets (MIMIC IV database). Results: The B-Score demonstrated reliable and desired properties. The real-world test provided allowed the direct comparison of different datasets and revealed insights hidden from absolute performance measures. The B-Score discriminates reliably between differing BP measurement performances and can detect similarities between measurement devices and their performances even when evaluated in different datasets. Conclusions: The B-Score demonstrated reliable and desired properties. The real-world test provided allowed the direct comparison of different datasets and revealed insights hidden from absolute performance measures. The B-Score discriminates reliably between differing BP measurement performances and can detect similarities between measurement devices and their performances even when evaluated in different datasets.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2025-05-01
DOI
https://doi.org/10.1097/01.hjh.0001116072.18248.57
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

THE B-SCORE IS A NOVEL METRIC FOR MEASURING THE TRUE PERFORMANCE OF BLOOD PRESSURE ESTIMATION MODELS

Niklas Pilz, Tomas L. Bothe, Andreas Reinhold Patzak
Journal of Hypertension
Hemodynamic Monitoring and Therapy
article

THE B-SCORE IS A NOVEL METRIC FOR MEASURING THE TRUE PERFORMANCE OF BLOOD PRESSURE ESTIMATION MODELS

Niklas Pilz, Tomas L. Bothe, Andreas Reinhold Patzak
article en

Abstract

Objective: Many novel blood pressure (BP) measurement technologies have been recently introduced into the market. Evaluating their measurement performance reliably and detecting important features of distinct technologies and devices is crucial for them to potentially reach clinical usability. To facilitate this, we developed a novel metric for the relative performance of blood pressure estimation systems (B-Score). Design and method: The B-Score sets absolute blood pressure estimation model performance in contrast to the dataset the model is tested upon. We calculate the B-Score based on inter- and intrapersonal variabilities within the dataset. To test the B-Score for reliable results and desired properties, we designed generic datasets with differing inter- and intrapersonal blood pressure variability. We then tested and validated the B-Score’s real-world functionality on large scale clinical datasets (MIMIC IV database). Results: The B-Score demonstrated reliable and desired properties. The real-world test provided allowed the direct comparison of different datasets and revealed insights hidden from absolute performance measures. The B-Score discriminates reliably between differing BP measurement performances and can detect similarities between measurement devices and their performances even when evaluated in different datasets. Conclusions: The B-Score demonstrated reliable and desired properties. The real-world test provided allowed the direct comparison of different datasets and revealed insights hidden from absolute performance measures. The B-Score discriminates reliably between differing BP measurement performances and can detect similarities between measurement devices and their performances even when evaluated in different datasets.

Journal of HypertensionVol. 43(Suppl 1)
Medizinische Hochschule Hannover (DE), Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE), Czech Academy of Sciences, Institute of Physiology (CZ), Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 80%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.