Effectiveness of paclitaxel-coated balloon angioplasty in prolonging arteriovenous fistula patency: A retrospective analysis from a single center in Latin America

IntroductionArteriovenous fistula (AVF) is the preferred method for vascular access. However, fistulas can fail and may develop stenosis. Therefore, maintaining the patency of the access is vital. Balloon angioplasty has been accepted as the first-line treatment for central venous stenosis. However, the reintervention rate with plain balloon angioplasty (PBA) is high. Drug-coated balloons (DCB) have emerged as a promising therapy for effectively prolonging the patency of treated vessels and reducing the reintervention rate. This study aims to determine the 12-month patency of arteriovenous fistulas following paclitaxel-coated balloon (PCB) angioplasty for central and peripheral venous stenosis.MethodsThis single-center retrospective analysis included patients with end-stage renal disease who underwent hemodialysis via native arteriovenous fistulas. The information was collected from medical records and compiled into a de-identified database provided by the institution. All patients were included regardless of sex or age, provided they had an angiography demonstrating central or peripheral venous stenosis and were treated with PCB. Patients were followed up every 3 months for 12 months at the vascular center. The primary objective was to ensure the vascular access was functioning effectively for hemodialysis and to monitor for any complications.ResultsA total of 137 patients with AVF dysfunction were treated with PCB; among them, 111 (81%) had central venous stenosis and 26 (19%) had peripheral venous stenosis. There was no significant difference in patency rates at 12-month follow-up between central (79%) and peripheral (85%) accesses. Factors associated with non-patency at 12-month follow-up were exhausted access (HR = 0.21, 95% IC 0.09-0.47, <i>p</i> < .001) and stenosis length greater than 20 mm (HR = 0.33, 95% IC 0.15-0.72, <i>p</i> = .005).ConclusionsThe high patency rate at 12 months for dysfunctional AVFs indicated that treatment with PCB is highly effective in both central and peripheral vein stenosis.

Authors

Institutions

Publication Details

Journal
Vascular
Published
2025-05-22
DOI
https://doi.org/10.1177/17085381251345540
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of paclitaxel-coated balloon angioplasty in prolonging arteriovenous fistula patency: A retrospective analysis from a single center in Latin America

Mario Alejandro Fabiani, Mónica S. Ponce-Rivera, Mario O’Connor, Paulina Elizabeth Cisneros Clavijo et al.
Vascular
Central Venous Catheters and Hemodialysis
article

Effectiveness of paclitaxel-coated balloon angioplasty in prolonging arteriovenous fistula patency: A retrospective analysis from a single center in Latin America

Mario Alejandro Fabiani, Mónica S. Ponce-Rivera, Mario O’Connor, Paulina Elizabeth Cisneros Clavijo, Jose G Ajila-Vacacela, Jorge Flores-Orduña
article en

Abstract

IntroductionArteriovenous fistula (AVF) is the preferred method for vascular access. However, fistulas can fail and may develop stenosis. Therefore, maintaining the patency of the access is vital. Balloon angioplasty has been accepted as the first-line treatment for central venous stenosis. However, the reintervention rate with plain balloon angioplasty (PBA) is high. Drug-coated balloons (DCB) have emerged as a promising therapy for effectively prolonging the patency of treated vessels and reducing the reintervention rate. This study aims to determine the 12-month patency of arteriovenous fistulas following paclitaxel-coated balloon (PCB) angioplasty for central and peripheral venous stenosis.MethodsThis single-center retrospective analysis included patients with end-stage renal disease who underwent hemodialysis via native arteriovenous fistulas. The information was collected from medical records and compiled into a de-identified database provided by the institution. All patients were included regardless of sex or age, provided they had an angiography demonstrating central or peripheral venous stenosis and were treated with PCB. Patients were followed up every 3 months for 12 months at the vascular center. The primary objective was to ensure the vascular access was functioning effectively for hemodialysis and to monitor for any complications.ResultsA total of 137 patients with AVF dysfunction were treated with PCB; among them, 111 (81%) had central venous stenosis and 26 (19%) had peripheral venous stenosis. There was no significant difference in patency rates at 12-month follow-up between central (79%) and peripheral (85%) accesses. Factors associated with non-patency at 12-month follow-up were exhausted access (HR = 0.21, 95% IC 0.09-0.47, <i>p</i> < .001) and stenosis length greater than 20 mm (HR = 0.33, 95% IC 0.15-0.72, <i>p</i> = .005).ConclusionsThe high patency rate at 12 months for dysfunctional AVFs indicated that treatment with PCB is highly effective in both central and peripheral vein stenosis.

VascularVol. 34(2)
Cardiovascular Institute of the South (US), Guthrie Foundation (US), The University of Texas at Austin (US), Tecnológico de Monterrey (MX)
Good health and well-being
Openalex Percentile: Top 81%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.