COMPARISON OF 24-HOUR BLOOD PRESSURE MONITORING USING THE CUFFLESS DEVICE, CART BP, AND CONVENTIONAL AMBULATORY BLOOD PRESSURE MONITORING

Objective: Cuffless blood pressure (BP) monitoring devices, such as the CART BP, offer a minimally invasive alternative to conventional ambulatory BP monitoring (ABPM). CART BP, a wearable ring-type device, uses photoplethysmography (PPG) to measure BP continuously, but its clinical applicability requires evaluation against standard 24-hour ABPM. We aimed to evaluate the feasibility and accuracy of 24-hour BP measurement using CART BP compared with the conventional ABPM, focusing on diurnal BP changes.Design and method: This study included 40 participants, with 33 completing the protocol. Participants wore both CART BP and ABPM devices on the same (non-dominant) arm for 24 hours. CART BP recorded BP every minute, while ABPM took readings at 20-minute intervals during the day and 30-minute intervals at night. Measurements from CART BP were compared with ABPM using correlation analyses and mean differences, and the impact of calibration positions was assessed. Results: CART BP generated approximately 10 times more readings than ABPM (754.2 ± 173.5 vs. 60.7 ± 4.6). Strong correlations were observed between CART BP and ABPM for systolic BP (SBP, r=0.886) and diastolic BP (DBP, r=0.843; both p<0.001). 24-hour BP measured by CART BP were shown significantly lower values, especially for daytime DBP (-5.9 ± 7.3 mmHg, p<0.001) and nighttime BP dips (SBP: 3.7 ± 5.6 mmHg vs. 7.4 ± 8.5 mmHg; DBP: 2.4 ± 2.8 mmHg vs. 6.3 ± 6.5 mmHg). It also classified more participants as DBP non-dippers (75.8% vs. 42.4%, p=0.003). Calibration strategies (multiple-position vs. sitting-only) did not significantly affect results. Conclusions: CART BP shows promise as a cuffless device for 24-hour BP monitoring, capturing more frequent data than ABPM. However, it underestimates BP values and demonstrates limited accuracy in tracking BP variability,

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2025-05-01
DOI
https://doi.org/10.1097/01.hjh.0001115996.64478.e7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARISON OF 24-HOUR BLOOD PRESSURE MONITORING USING THE CUFFLESS DEVICE, CART BP, AND CONVENTIONAL AMBULATORY BLOOD PRESSURE MONITORING

Hae‐Young Lee, H. K. Lee
1 links
Journal of Hypertension
Non-Invasive Vital Sign Monitoring
article

COMPARISON OF 24-HOUR BLOOD PRESSURE MONITORING USING THE CUFFLESS DEVICE, CART BP, AND CONVENTIONAL AMBULATORY BLOOD PRESSURE MONITORING

Hae‐Young Lee, H. K. Lee
article en

Abstract

Objective: Cuffless blood pressure (BP) monitoring devices, such as the CART BP, offer a minimally invasive alternative to conventional ambulatory BP monitoring (ABPM). CART BP, a wearable ring-type device, uses photoplethysmography (PPG) to measure BP continuously, but its clinical applicability requires evaluation against standard 24-hour ABPM. We aimed to evaluate the feasibility and accuracy of 24-hour BP measurement using CART BP compared with the conventional ABPM, focusing on diurnal BP changes.Design and method: This study included 40 participants, with 33 completing the protocol. Participants wore both CART BP and ABPM devices on the same (non-dominant) arm for 24 hours. CART BP recorded BP every minute, while ABPM took readings at 20-minute intervals during the day and 30-minute intervals at night. Measurements from CART BP were compared with ABPM using correlation analyses and mean differences, and the impact of calibration positions was assessed. Results: CART BP generated approximately 10 times more readings than ABPM (754.2 ± 173.5 vs. 60.7 ± 4.6). Strong correlations were observed between CART BP and ABPM for systolic BP (SBP, r=0.886) and diastolic BP (DBP, r=0.843; both p<0.001). 24-hour BP measured by CART BP were shown significantly lower values, especially for daytime DBP (-5.9 ± 7.3 mmHg, p<0.001) and nighttime BP dips (SBP: 3.7 ± 5.6 mmHg vs. 7.4 ± 8.5 mmHg; DBP: 2.4 ± 2.8 mmHg vs. 6.3 ± 6.5 mmHg). It also classified more participants as DBP non-dippers (75.8% vs. 42.4%, p=0.003). Calibration strategies (multiple-position vs. sitting-only) did not significantly affect results. Conclusions: CART BP shows promise as a cuffless device for 24-hour BP monitoring, capturing more frequent data than ABPM. However, it underestimates BP values and demonstrates limited accuracy in tracking BP variability,

Journal of HypertensionVol. 43(Suppl 1)
Seoul National University Hospital (KR)
Good health and well-being
Openalex Percentile: Top 89%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

COMPARISON OF 24-HOUR BLOOD PRESSURE MONITORING USING THE CUFFLESS DEVICE, CART BP, AND CONVENTIONAL AMBULATORY BLOOD PRESSURE MONITORING — Hae‐Young Lee, H. K. Lee · Journal of Hypertension (2025) | TGRS Research Map | TGRS