A CLOSED-LOOP ANTIHYPERTENSIVE DRUG-DELIVERY SYSTEM FOR MANAGEMENT OF HYPERTENSION AND BLOOD PRESSURE VARIABILITY

Objective: Hypertension remains the leading cause of cardiovascular (CV) morbidity and mortality worldwide. Despite current treatments, blood pressure (BP) control is often suboptimal, with BP variability (BPV) emerging as a significant risk factor for CV events. Novel wearable BP measurement technologies highlight the potential for improved BPV monitoring, underscoring the urgent need for targeted therapies. This study aims to develop an implantable, closed-loop system using esmolol hydrochloride to optimise BP control and minimise BPV.Design and method: A two-phase experimental approach is being undertaken using stroke-prone spontaneously hypertensive rats. Phase 1: Incremental doses of esmolol are administered via a subcutaneous pump following a fixed oral dose of amlodipine to establish dose-response curves. Phase 2: Proportional-integral-derivative (PID) algorithms derived from Phase 1 data will guide the timing and dosage of esmolol release. The closed-loop system will incorporate real-time BP and heart rate (HR) data to minimise BPV, measured by the coefficient of variation (CoV). Results: Preliminary findings indicate that locomotor activity significantly confounds BP and HR measurements. This underscores the importance of integrating activity data, obtained via radiotelemetry, into the development of the PID algorithms. The closed-loop system comprises: i) radiotelemetry-based BP, HR and activity measurement; ii) a controller with PID algorithms to determine esmolol dosing; iii) an implantable subcutaneous pump for drug delivery. A custom application enables live monitoring of BP, HR, and CoV during administration. Algorithm validation will be conducted on an existing BP dataset, with further refinement informed by real-time experimental data. Conclusions: The dose-response study highlights the influence of locomotor activity on BP, BPV and HR, necessitating its incorporation into algorithm design. Future steps include a dose-response experiment in anaesthetised swine to eliminate activity-related confounding prior to testing the closed-loop system in animal models. This novel approach holds promise for advancing BPV management through precise, real-time control.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2025-05-01
DOI
https://doi.org/10.1097/01.hjh.0001116416.81634.8f
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A CLOSED-LOOP ANTIHYPERTENSIVE DRUG-DELIVERY SYSTEM FOR MANAGEMENT OF HYPERTENSION AND BLOOD PRESSURE VARIABILITY

Garry P. Duffy, James Curneen, Conor Judge, Sally‐Ann Cryan et al.
Journal of Hypertension
Hormonal Regulation and Hypertension
article

A CLOSED-LOOP ANTIHYPERTENSIVE DRUG-DELIVERY SYSTEM FOR MANAGEMENT OF HYPERTENSION AND BLOOD PRESSURE VARIABILITY

Garry P. Duffy, James Curneen, Conor Judge, Sally‐Ann Cryan, Joanne O’Dwyer, Delyth Graham
article en

Abstract

Objective: Hypertension remains the leading cause of cardiovascular (CV) morbidity and mortality worldwide. Despite current treatments, blood pressure (BP) control is often suboptimal, with BP variability (BPV) emerging as a significant risk factor for CV events. Novel wearable BP measurement technologies highlight the potential for improved BPV monitoring, underscoring the urgent need for targeted therapies. This study aims to develop an implantable, closed-loop system using esmolol hydrochloride to optimise BP control and minimise BPV.Design and method: A two-phase experimental approach is being undertaken using stroke-prone spontaneously hypertensive rats. Phase 1: Incremental doses of esmolol are administered via a subcutaneous pump following a fixed oral dose of amlodipine to establish dose-response curves. Phase 2: Proportional-integral-derivative (PID) algorithms derived from Phase 1 data will guide the timing and dosage of esmolol release. The closed-loop system will incorporate real-time BP and heart rate (HR) data to minimise BPV, measured by the coefficient of variation (CoV). Results: Preliminary findings indicate that locomotor activity significantly confounds BP and HR measurements. This underscores the importance of integrating activity data, obtained via radiotelemetry, into the development of the PID algorithms. The closed-loop system comprises: i) radiotelemetry-based BP, HR and activity measurement; ii) a controller with PID algorithms to determine esmolol dosing; iii) an implantable subcutaneous pump for drug delivery. A custom application enables live monitoring of BP, HR, and CoV during administration. Algorithm validation will be conducted on an existing BP dataset, with further refinement informed by real-time experimental data. Conclusions: The dose-response study highlights the influence of locomotor activity on BP, BPV and HR, necessitating its incorporation into algorithm design. Future steps include a dose-response experiment in anaesthetised swine to eliminate activity-related confounding prior to testing the closed-loop system in animal models. This novel approach holds promise for advancing BPV management through precise, real-time control.

Journal of HypertensionVol. 43(Suppl 1)
Royal College of Surgeons in Ireland (IE), Ollscoil na Gaillimhe – University of Galway (IE), University of Glasgow (GB)
Good health and well-being
Openalex Percentile: Top 84%
Hormonal Regulation and Hypertension
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.