Reliability of short-term measurement of heart rate variability on rest in individuals with temporomandibular disorder

Individuals with temporomandibular disorder (TMD) experience autonomic dysfunction, which disrupts the balance between the sympathetic and parasympathetic nervous systems. This imbalance can result in altered heart rate variability (HRV) and other physiological disturbances. However, it is important to note that, to date, no research has investigated the inter- and intra-rater reliability of HRV measurements in individuals with TMD. The objective of this investigation was to analyze the intra- and inter-examiner reliability of HRV captured by a polar heart rate monitor in individuals with TMD. The RR interval, the time elapsed between two successive R-waves of the QRS signal on the electrocardiogram (RRi), were recorded during a 10 min period in a supine position using a portable heart rate monitor (Polar® V800 model). The data were transferred into Kubios® HRV standard analysis software and analyzed within the stable sessions containing 5 min sequential RRi. The intraclass correlation coefficient (ICC) ranged from 0.907 to 0.998 according to the intra-examiner analysis by Examiner 1 and 0.875 to 0.998 according to the intra-examiner by Examiner 2. The inter-examiner ICC ranged from 0.796 to 0.996. The coefficient of variation was up to 9.60 for Examiner 1 intra-examiner analysis, 11.95 for Examiner 2 intra-examiner analysis and 14.88 for inter-examiner analysis. The HRV analysis captured by a Polar cardio frequency meter presented adequate reliability when considering different times and examiners. Intra-examiner reliability showed ICC values ranging from 0.842 to 0.999, and inter-examiner reliability ranged from 0.796 to 0.994. Bland-Altman plots indicated good agreement with minimal bias. Coefficients of variation were below 10% for most variables.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-22
DOI
https://doi.org/10.1038/s41598-025-00560-y
Citations
1
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of short-term measurement of heart rate variability on rest in individuals with temporomandibular disorder

Maria Cláudia Gonçalves, Janaína de Oliveira Brito-Monzani, Almir Vieira Dibai‐Filho, Cassius Iury Anselmo-e-Silva et al.
1 citations
Scientific Reports
Heart Rate Variability and Autonomic Control
1.39
article

Reliability of short-term measurement of heart rate variability on rest in individuals with temporomandibular disorder

Maria Cláudia Gonçalves, Janaína de Oliveira Brito-Monzani, Almir Vieira Dibai‐Filho, Cassius Iury Anselmo-e-Silva, Aldair Darlan Santos‐de‐Araújo, Daniela Bassi‐Dibai, Rodrigo Costa Cutrim, Etevaldo Matos Maia Filho, Rudys Rodolfo de Jesus Tavarez, Audrey Borghi-Silva
article en
1 citations

Abstract

Individuals with temporomandibular disorder (TMD) experience autonomic dysfunction, which disrupts the balance between the sympathetic and parasympathetic nervous systems. This imbalance can result in altered heart rate variability (HRV) and other physiological disturbances. However, it is important to note that, to date, no research has investigated the inter- and intra-rater reliability of HRV measurements in individuals with TMD. The objective of this investigation was to analyze the intra- and inter-examiner reliability of HRV captured by a polar heart rate monitor in individuals with TMD. The RR interval, the time elapsed between two successive R-waves of the QRS signal on the electrocardiogram (RRi), were recorded during a 10 min period in a supine position using a portable heart rate monitor (Polar® V800 model). The data were transferred into Kubios® HRV standard analysis software and analyzed within the stable sessions containing 5 min sequential RRi. The intraclass correlation coefficient (ICC) ranged from 0.907 to 0.998 according to the intra-examiner analysis by Examiner 1 and 0.875 to 0.998 according to the intra-examiner by Examiner 2. The inter-examiner ICC ranged from 0.796 to 0.996. The coefficient of variation was up to 9.60 for Examiner 1 intra-examiner analysis, 11.95 for Examiner 2 intra-examiner analysis and 14.88 for inter-examiner analysis. The HRV analysis captured by a Polar cardio frequency meter presented adequate reliability when considering different times and examiners. Intra-examiner reliability showed ICC values ranging from 0.842 to 0.999, and inter-examiner reliability ranged from 0.796 to 0.994. Bland-Altman plots indicated good agreement with minimal bias. Coefficients of variation were below 10% for most variables.

Scientific ReportsVol. 15(1)
Universidade Federal de São Carlos (BR), Universidade Ceuma (BR), Universidade Federal do Maranhão (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 19%
Heart Rate Variability and Autonomic Control
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.