An Upgraded FOS/TAC Titration Model Integrating Phosphate Effects for Accurate Assessments of Volatile Fatty Acids and Alkalinity in Anaerobic Media

The accurate determination of volatile fatty acids (VFAs) and total alkalinity (TAC, mostly carried by bicarbonate ions) is critical for operating anaerobic digesters. The FOS/TAC titration method developed by Nordmann is widely used due to its simplicity and affordability. This method has known limitations in dosing VFAs and TAC, since the presence of one interferes with the determination of the other, especially at higher VFA or bicarbonate concentrations. This study builds upon our prior research in 2021 by integrating the influence of phosphate (H2PO4−/HPO42−) into numerical models correcting FOS/TAC titration results. A Scilab-based program was used to assess the impact of phosphate on titration results, revealing significant biases at lower concentrations. A revised multivariate regression formula was developed, incorporating phosphate effects, and demonstrating superior accuracy. The mean absolute percentage errors (MAPE) for TAC and VFA estimation were reduced to less than 0.3%. The model maintains compatibility with standard Nordmann’s titration protocols and equipment while significantly improving reliability. These findings highlight the necessity of considering phosphate interference in FOS/TAC titration, particularly in AD systems with variable buffering conditions. The proposed correction model enhances process monitoring and control, providing a more robust tool for both research and industrial practice in anaerobic digestion.

Authors

Institutions

Publication Details

Journal
ChemEngineering
Published
2025-05-22
DOI
https://doi.org/10.3390/chemengineering9030053
Citations
1
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
0.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Upgraded FOS/TAC Titration Model Integrating Phosphate Effects for Accurate Assessments of Volatile Fatty Acids and Alkalinity in Anaerobic Media

Thierry Ribeiro, Xiaojun Liu, André Pauss, Laura André
1 citations
ChemEngineering
Wastewater Treatment and Nitrogen Removal
0.50
article

An Upgraded FOS/TAC Titration Model Integrating Phosphate Effects for Accurate Assessments of Volatile Fatty Acids and Alkalinity in Anaerobic Media

Thierry Ribeiro, Xiaojun Liu, André Pauss, Laura André
article en
1 citations

Abstract

The accurate determination of volatile fatty acids (VFAs) and total alkalinity (TAC, mostly carried by bicarbonate ions) is critical for operating anaerobic digesters. The FOS/TAC titration method developed by Nordmann is widely used due to its simplicity and affordability. This method has known limitations in dosing VFAs and TAC, since the presence of one interferes with the determination of the other, especially at higher VFA or bicarbonate concentrations. This study builds upon our prior research in 2021 by integrating the influence of phosphate (H2PO4−/HPO42−) into numerical models correcting FOS/TAC titration results. A Scilab-based program was used to assess the impact of phosphate on titration results, revealing significant biases at lower concentrations. A revised multivariate regression formula was developed, incorporating phosphate effects, and demonstrating superior accuracy. The mean absolute percentage errors (MAPE) for TAC and VFA estimation were reduced to less than 0.3%. The model maintains compatibility with standard Nordmann’s titration protocols and equipment while significantly improving reliability. These findings highlight the necessity of considering phosphate interference in FOS/TAC titration, particularly in AD systems with variable buffering conditions. The proposed correction model enhances process monitoring and control, providing a more robust tool for both research and industrial practice in anaerobic digestion.

ChemEngineeringVol. 9(3)
Université de Technologie de Compiègne (FR), Sorbonne Université (FR), École Supérieure de Chimie Organique et Minérale (FR), Université d'Artois (FR)
Industry, innovation and infrastructure
Openalex Percentile: Top 40%
Wastewater Treatment and Nitrogen Removal
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.