Handling of Human Ejaculate Affects Osmolality and Yield by Density Gradient Centrifugation and Possibly Also Sperm DNA Integrity

During routine handling in the assisted reproductive technology (ART) laboratory, the osmolality of the ejaculate increases, and live spermatozoa adapt to this increase. Preparation media are generally isotonic, having an osmolality of ~290 mOsm/kg. Therefore, when the ejaculate is placed on a density gradient, the spermatozoa are exposed to a hypotonic challenge. The aim of this study was to investigate whether osmotic challenges affect the yield of density gradient centrifugation (DGC), the DNA fragmentation index (%DFI), and the proportion of high DNA stainable sperm (%HDS). Furthermore, it was investigated if these effects could be counteracted by dilution of the ejaculate. Semen samples from healthy donors were collected and used after written consent. Four protocols of different experimental conditions were followed. These included storage at 37°C, storage at room temperature (RT), dilution after liquefaction, and ejaculation directly into a buffer. Pairwise comparisons of the studied aliquot and its own control were performed. Storage at 37°C led to an increase in osmolality to 352 mOsm/kg and halved the yield to 4.5%. Storage at RT led to an increase in osmolality to 384 mOsm/kg and halved the yield to 5.8%. The %DFI and %HDS did not change during these storage conditions. In undiluted samples, osmolality increased to 373 mOsm/kg and in diluted to 323 mOsm/kg. The %DFI and %HDS did not change. After ejaculation into a buffer, the osmolality increased only to 315 mOsm/kg after storage and the yield halved after storage to 12.9%. The %DFI was significantly lower after ejaculation into a buffer compared to dilution after liquefaction, 6% versus 11%, respectively. No difference was observed in %HDS. The challenges to sperm function induced by osmolality changes, and possibly also sperm DNA integrity, can be counteracted by collecting ejaculates directly into an isotonic buffer.

Authors

Institutions

Publication Details

Journal
Andrologia
Published
2025-01-01
DOI
https://doi.org/10.1155/and/4015844
Primary Topic
Sperm and Testicular Function
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Handling of Human Ejaculate Affects Osmolality and Yield by Density Gradient Centrifugation and Possibly Also Sperm DNA Integrity

Lars Björndahl, Petr Houska, Ulrik Kvist, Emma Holmes
Andrologia
Sperm and Testicular Function
article

Handling of Human Ejaculate Affects Osmolality and Yield by Density Gradient Centrifugation and Possibly Also Sperm DNA Integrity

Lars Björndahl, Petr Houska, Ulrik Kvist, Emma Holmes
article en

Abstract

During routine handling in the assisted reproductive technology (ART) laboratory, the osmolality of the ejaculate increases, and live spermatozoa adapt to this increase. Preparation media are generally isotonic, having an osmolality of ~290 mOsm/kg. Therefore, when the ejaculate is placed on a density gradient, the spermatozoa are exposed to a hypotonic challenge. The aim of this study was to investigate whether osmotic challenges affect the yield of density gradient centrifugation (DGC), the DNA fragmentation index (%DFI), and the proportion of high DNA stainable sperm (%HDS). Furthermore, it was investigated if these effects could be counteracted by dilution of the ejaculate. Semen samples from healthy donors were collected and used after written consent. Four protocols of different experimental conditions were followed. These included storage at 37°C, storage at room temperature (RT), dilution after liquefaction, and ejaculation directly into a buffer. Pairwise comparisons of the studied aliquot and its own control were performed. Storage at 37°C led to an increase in osmolality to 352 mOsm/kg and halved the yield to 4.5%. Storage at RT led to an increase in osmolality to 384 mOsm/kg and halved the yield to 5.8%. The %DFI and %HDS did not change during these storage conditions. In undiluted samples, osmolality increased to 373 mOsm/kg and in diluted to 323 mOsm/kg. The %DFI and %HDS did not change. After ejaculation into a buffer, the osmolality increased only to 315 mOsm/kg after storage and the yield halved after storage to 12.9%. The %DFI was significantly lower after ejaculation into a buffer compared to dilution after liquefaction, 6% versus 11%, respectively. No difference was observed in %HDS. The challenges to sperm function induced by osmolality changes, and possibly also sperm DNA integrity, can be counteracted by collecting ejaculates directly into an isotonic buffer.

AndrologiaVol. 2025(1)
Karolinska University Hospital (SE)
Karolinska Institutet
Openalex Percentile: Top 84%
Sperm and Testicular Function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.