Safety Assessment of Loop Closing in Active Distribution Networks Based on Probabilistic Power Flow

To investigate the security issues of loop-closing operations in medium–low-voltage distribution networks under the influence of stochastic fluctuations from distributed generators (DGs) and loads, probabilistic power flow is introduced for analyzing loop-closing currents in active distribution networks. A novel method combining Latin Hypercube Sampling (LHS) and the Gram–Charlier (GC) series, termed the LHS-GC method, is proposed to calculate the probability distribution of loop-closing currents. By modeling DGs and loads as random variables, their cumulants are efficiently obtained through LHS. Based on a linearized formulation of loop-closing current equations, the cumulants of loop-closing currents are calculated, ultimately reconstructing the probability distribution function of loop-closing currents in active distribution networks. Subsequently, a security assessment framework for loop-closing operations is established using the probability distribution of loop-closing currents. This framework provides a quantitative evaluation from two dimensions: preliminary loop-closing success rate and the severity of current limit violations, offering data-driven decision support for loop-closing operations. Taking the IEEE 34-node distribution network as an example for feeder loop-closing current assessment, the proposed LHS-GC method achieves results with less than 4% deviation from simulation values in terms of cumulative probability distribution of loop-closing currents and safety assessment metrics. Under a sampling scale of 500 points, the computational time is 0.76 s, demonstrating its efficiency and reliability. These outcomes provide actionable references for decision-making support in loop-closing operations of active distribution networks.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-22
DOI
https://doi.org/10.3390/en18112685
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety Assessment of Loop Closing in Active Distribution Networks Based on Probabilistic Power Flow

Wenchao Cai, Jiaoxin Jia, Yuan Gao, Si Qin et al.
Energies
Smart Grid and Power Systems
article

Safety Assessment of Loop Closing in Active Distribution Networks Based on Probabilistic Power Flow

Wenchao Cai, Jiaoxin Jia, Yuan Gao, Si Qin, Xiping Zhang, Bingzhen Li
article en

Abstract

To investigate the security issues of loop-closing operations in medium–low-voltage distribution networks under the influence of stochastic fluctuations from distributed generators (DGs) and loads, probabilistic power flow is introduced for analyzing loop-closing currents in active distribution networks. A novel method combining Latin Hypercube Sampling (LHS) and the Gram–Charlier (GC) series, termed the LHS-GC method, is proposed to calculate the probability distribution of loop-closing currents. By modeling DGs and loads as random variables, their cumulants are efficiently obtained through LHS. Based on a linearized formulation of loop-closing current equations, the cumulants of loop-closing currents are calculated, ultimately reconstructing the probability distribution function of loop-closing currents in active distribution networks. Subsequently, a security assessment framework for loop-closing operations is established using the probability distribution of loop-closing currents. This framework provides a quantitative evaluation from two dimensions: preliminary loop-closing success rate and the severity of current limit violations, offering data-driven decision support for loop-closing operations. Taking the IEEE 34-node distribution network as an example for feeder loop-closing current assessment, the proposed LHS-GC method achieves results with less than 4% deviation from simulation values in terms of cumulative probability distribution of loop-closing currents and safety assessment metrics. Under a sampling scale of 500 points, the computational time is 0.76 s, demonstrating its efficiency and reliability. These outcomes provide actionable references for decision-making support in loop-closing operations of active distribution networks.

EnergiesVol. 18(11)
North China Electric Power University (CN), Inner Mongolia Electric Power (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 91%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.