Comparative characteristics of facial scanners

The development of digital technologies and devices used in orthopedic dentistry makes it possible to reduce the time for making a prosthesis, reduce costs and improve the quality of manufactured prostheses. One of the most important stages in the production of a prosthesis in a digital protocol is the stage of obtaining digital impressions, which must be as accurate as possible. Goal — to experimentally evaluate the accuracy of three-dimensional images and determine the most suitable models of facial scanners, optimal in terms of price and quality ratio. Materials and Methods.The study examined four scanner models: 3dMDface, ObiScanner, Einstar, and Planmeca ProMax 3D ProFace. The reference model chosen was the stationary scanner VT MINI V2 (Volume Technologies, Russia). A facial mannequin with areas of textured surface was used, and specific points (grooves, indentations) were selected, as these points could be reproduced across different scans: points 1 and 2 represent the outer corners of the eyes, points 3 and 4 correspond to the corners of the mouth, and point 5 indicates the chin. All obtained images were imported into the Exocad software, where each scan was sequentially overlaid onto the reference model scan, and the distance between the scans was measured. Five such studies were conducted for each scanner. Results. The ObiScanner demonstrated the least deviation from the reference scan at a greater number of points: point 1 — 0.069 mm; point 4 — 0.015 mm; point 5 — 0.045 mm, and it is also acceptable in terms of price and availability. The Planmeca ProMax 3D ProFace scanner showed the least deviation from the reference scan at point 3 (0.008 mm), but it is the most expensive among the scanners involved in the study. The 3dMDface scanner had the least deviation at point 2 (0.068 mm) from the reference, but it is the most difficult to access and the second most expensive among the scanners in the study. The Einstar scanner exhibited higher deviation values from the reference scan at each point compared to the other scanners involved in the study, but it has the lowest cost and is easily accessible for purchase.

Authors

Institutions

Publication Details

Journal
Clinical Dentistry (Russia)
Published
2025-04-07
DOI
https://doi.org/10.37988/1811-153x_2025_1_110
Primary Topic
Digital Imaging in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative characteristics of facial scanners

Valeria K. Suonio, А.Г. Степанов, Leon S. Grigoryants, Samvel V. Apresyan et al.
Clinical Dentistry (Russia)
Digital Imaging in Medicine
article

Comparative characteristics of facial scanners

Valeria K. Suonio, А.Г. Степанов, Leon S. Grigoryants, Samvel V. Apresyan, Anastasia P. Zrazhevskaya
article en

Abstract

The development of digital technologies and devices used in orthopedic dentistry makes it possible to reduce the time for making a prosthesis, reduce costs and improve the quality of manufactured prostheses. One of the most important stages in the production of a prosthesis in a digital protocol is the stage of obtaining digital impressions, which must be as accurate as possible. Goal — to experimentally evaluate the accuracy of three-dimensional images and determine the most suitable models of facial scanners, optimal in terms of price and quality ratio. Materials and Methods.The study examined four scanner models: 3dMDface, ObiScanner, Einstar, and Planmeca ProMax 3D ProFace. The reference model chosen was the stationary scanner VT MINI V2 (Volume Technologies, Russia). A facial mannequin with areas of textured surface was used, and specific points (grooves, indentations) were selected, as these points could be reproduced across different scans: points 1 and 2 represent the outer corners of the eyes, points 3 and 4 correspond to the corners of the mouth, and point 5 indicates the chin. All obtained images were imported into the Exocad software, where each scan was sequentially overlaid onto the reference model scan, and the distance between the scans was measured. Five such studies were conducted for each scanner. Results. The ObiScanner demonstrated the least deviation from the reference scan at a greater number of points: point 1 — 0.069 mm; point 4 — 0.015 mm; point 5 — 0.045 mm, and it is also acceptable in terms of price and availability. The Planmeca ProMax 3D ProFace scanner showed the least deviation from the reference scan at point 3 (0.008 mm), but it is the most expensive among the scanners involved in the study. The 3dMDface scanner had the least deviation at point 2 (0.068 mm) from the reference, but it is the most difficult to access and the second most expensive among the scanners in the study. The Einstar scanner exhibited higher deviation values from the reference scan at each point compared to the other scanners involved in the study, but it has the lowest cost and is easily accessible for purchase.

Clinical Dentistry (Russia)Vol. 28(1)
Peoples' Friendship University of Russia (RU)
Openalex Percentile: Top 84%
Digital Imaging in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.