Feasibility Study of Thallium Bromide Detectors for Boron Neutron Capture Therapy Applications

A thallium bromide (TlBr) detector with four-channel readout electrodes was fabricated from a crystal grown by the traveling molten zone method from a zone-purified material for boron neutron capture therapy applications.The detector crystal dimensions were 12 12 10 mm 3 .The detector had four circular anodes of 2 mm diameter.The detector exhibited energy resolutions sufficient to resolve 478 keV gamma rays from 511 keV gamma rays.A prompt gamma-ray detection system was constructed using the TlBr detector and a tungsten collimator.A mouse phantom with a tumor sphere containing 1475 ppm 10 B was irradiated with thermal neutrons.The 10 B distribution was imaged successfully with the TlBr detector system.The detector system exhibited a linear relationship between the counts for 478 keV and the 10 B concentration in the range of 0-5000 ppm.

Authors

Publication Details

Journal
Sensors and Materials
Published
2025-05-22
DOI
https://doi.org/10.18494/sam5613
Citations
3
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
4.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility Study of Thallium Bromide Detectors for Boron Neutron Capture Therapy Applications

Hiroki Tanaka, Nishiki Matsubayashi, Keitaro Hitomi, Kenichi Watanabe et al.
3 citations
Sensors and Materials
Boron Compounds in Chemistry
4.08
article

Feasibility Study of Thallium Bromide Detectors for Boron Neutron Capture Therapy Applications

Hiroki Tanaka, Nishiki Matsubayashi, Keitaro Hitomi, Kenichi Watanabe, Mitsuhiro Nogami
article en
3 citations

Abstract

A thallium bromide (TlBr) detector with four-channel readout electrodes was fabricated from a crystal grown by the traveling molten zone method from a zone-purified material for boron neutron capture therapy applications.The detector crystal dimensions were 12 12 10 mm 3 .The detector had four circular anodes of 2 mm diameter.The detector exhibited energy resolutions sufficient to resolve 478 keV gamma rays from 511 keV gamma rays.A prompt gamma-ray detection system was constructed using the TlBr detector and a tungsten collimator.A mouse phantom with a tumor sphere containing 1475 ppm 10 B was irradiated with thermal neutrons.The 10 B distribution was imaged successfully with the TlBr detector system.The detector system exhibited a linear relationship between the counts for 478 keV and the 10 B concentration in the range of 0-5000 ppm.

Sensors and MaterialsVol. 37(5)
Japan Society for the Promotion of Science
Openalex Percentile: Top 6%
Boron Compounds in Chemistry
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.