FBG-based force-sensing gripper in minimally invasive robot-assisted laparoscopic surgery

Robot-assisted surgery (RAS) has emerged as a groundbreaking technique retaining much of the functionality of traditional open surgery in terms of visibility, flexibility and precision, whilst the minimally invasive incision adds benefits in healing time and reduced risk of complications. Force feedback plays a crucial role in ensuring surgical safety and effectiveness, as excessive or inappropriate forces can result in unwanted tissue damage, bleeding and/or poor outcome. In the work reported here, we embedded fibre Bragg grating (FBG) sensors along the length of a standard minimally invasive surgical gripper jaw to measure the strain resulting from a clamping force applied at the tip of the jaw. We have found that the FBG has sufficient sensitivity to monitor surgically relevant forces without excessive deformation. Future work will explore multi-axis strain measurements to monitor different types of force experienced by the gripper.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3061864
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FBG-based force-sensing gripper in minimally invasive robot-assisted laparoscopic surgery

William N. MacPherson, Duncan P. Hand, R.L. Reuben, Mark W. McDonald et al.
Soft Robotics and Applications
article

FBG-based force-sensing gripper in minimally invasive robot-assisted laparoscopic surgery

William N. MacPherson, Duncan P. Hand, R.L. Reuben, Mark W. McDonald, Calum Anderson, Yuhang Chen, Wei Feng, David C. Smith
article en

Abstract

Robot-assisted surgery (RAS) has emerged as a groundbreaking technique retaining much of the functionality of traditional open surgery in terms of visibility, flexibility and precision, whilst the minimally invasive incision adds benefits in healing time and reduced risk of complications. Force feedback plays a crucial role in ensuring surgical safety and effectiveness, as excessive or inappropriate forces can result in unwanted tissue damage, bleeding and/or poor outcome. In the work reported here, we embedded fibre Bragg grating (FBG) sensors along the length of a standard minimally invasive surgical gripper jaw to measure the strain resulting from a clamping force applied at the tip of the jaw. We have found that the FBG has sufficient sensitivity to monitor surgically relevant forces without excessive deformation. Future work will explore multi-axis strain measurements to monitor different types of force experienced by the gripper.

CMR Surgical (United Kingdom) (GB)
Openalex Percentile: Top 90%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.