Optical fiber sensor for assessing asphaltene content in crude oil

An optical fiber sensor is described for monitoring asphaltene content in crude oil samples, utilizing a no-core fiber segment spliced between two multimode fibers. Light transmitted through the no-core fiber section is attenuated due to the presence of scattering and absorbing effects in the surrounding medium. The sensor assesses asphaltene precipitation in a crude oil/n-heptane solution, correlating asphaltene concentration with the resulting transmission loss. Tests on four crude oil samples from different extractions and oil deposits, with asphaltene content ranging from 1% to 8.4% w/w, revealed a distinct transmission loss per sample and an exponentially increasing loss trend with regard to asphaltene content. The recorded transmission loss (after 1 hour of precipitation), measured with the non-core optical fiber sensor, ranged from 1.9 dB to 8.5 dB for the aforementioned asphaltene content values.

Authors

Institutions

Publication Details

Published
2025-05-22
DOI
https://doi.org/10.1117/12.3062252
Primary Topic
Petroleum Processing and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical fiber sensor for assessing asphaltene content in crude oil

Maria Konstantaki, Ν. Pasadakis, Stavros Pissadakis, Eleftheria Antoniou et al.
Petroleum Processing and Analysis
article

Optical fiber sensor for assessing asphaltene content in crude oil

Maria Konstantaki, Ν. Pasadakis, Stavros Pissadakis, Eleftheria Antoniou, Elina Chamilaki, Vasilios Sarakatsianos
article en

Abstract

An optical fiber sensor is described for monitoring asphaltene content in crude oil samples, utilizing a no-core fiber segment spliced between two multimode fibers. Light transmitted through the no-core fiber section is attenuated due to the presence of scattering and absorbing effects in the surrounding medium. The sensor assesses asphaltene precipitation in a crude oil/n-heptane solution, correlating asphaltene concentration with the resulting transmission loss. Tests on four crude oil samples from different extractions and oil deposits, with asphaltene content ranging from 1% to 8.4% w/w, revealed a distinct transmission loss per sample and an exponentially increasing loss trend with regard to asphaltene content. The recorded transmission loss (after 1 hour of precipitation), measured with the non-core optical fiber sensor, ranged from 1.9 dB to 8.5 dB for the aforementioned asphaltene content values.

Technical University of Crete (GR), Foundation for Research and Technology Hellas (GR)
Openalex Percentile: Top 88%
Petroleum Processing and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.